• 제목/요약/키워드: Spliced

검색결과 229건 처리시간 0.026초

강판보강에 의한 운형 RC 교각의 내진성능 향상 (Seismic Upgrading of Existing Circular RC Pier with Steel Jacket)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.341-348
    • /
    • 2000
  • The existing solid circular RC pier without seismic detailing is found to have poor ductility due to the premature bond failure of lap spliced longitudinal bars. The steel-jacket was introduced to prevent this unexpected type of failure. The nonlinear behavior and he seismic performance of the retrofitted pier were examined through the scale model test and compared with those of existing one. It is confirmed from the test results that the steel-jacket retrofitting can be used as an measure to improve seismic performance considerably.

  • PDF

기존 원형교각의 휨성능 개선을 위한 FRP활용 내진보강 (Seismic Retrofit of Existing Circular Bridge Columns Using FRP for Flexural Performance Enhancement)

  • 권태규;최영민;황윤국;윤순종
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.793-798
    • /
    • 2002
  • This paper presents the analytical results on the seismic retrofit of circular bridge columns with poor lap-splice details using FRP jacket. The as-built column suffered brittle failure due to the deterioration of lap-spliced longitudinal reinforcement without developing its flexural capacity or ductility. The retrofitted columns using FRP jacket showed significant improvement in seismic performance due to FRP's confinement effect. FRP's confinement effect is predicted by the classical elasticity solution for the laminated circular tube manufactural with several layers, and induces the flexural failure instead of bondslip failure.

  • PDF

철근 기계적 이음 콘크리트 보의 단순가력에 의한 파괴거동(I) (Structural Behavior of Concrete Beam with Mechanically Spliced Re-bars Subjected to Monotonic Loading (I))

  • 나환선;이현주;권기주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.150-153
    • /
    • 2006
  • The purpose of this research is focused on evaluating the flexural behavior of reinforced concrete beam having 22mm diameter re-bars by lapping methods. To compare the existent lapping method with mechanical lapping methods, four cases of concrete beams were tested to be failed flexurally by monotonic loading. Based on test results, the relations between load and displacement, ductility, maximum load was comparatively analyzed. The structural performance on four cases of members were evaluated.

  • PDF

분리형 거더의 역학적 거동 특성에 관한 실험 (An Experimental Study for Mechanical Behavior of Multi-Segment Girder)

  • 서봉원;김광수;박선규;김수만;이종은
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.186-189
    • /
    • 2003
  • Precast Segmental method was developed in germany 1950s. This method has been adoptted in long span girder mainly owing to easy construction effect. But, so far, The limit exists that this method is constructed in a portion of span and hard conveyance and foundation. This study was performed to analysis behavior difference of two rectanglar section girder, spliced girder that was jointed 5-sliced 0.8m segment and monolithic girder that was produced in one body 4m span

  • PDF

결속선이 R/C보의 거동에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of Tie-wire on R/C Beam Behaviors)

  • 변항룡;공귀옥;김준성;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.737-742
    • /
    • 1997
  • In this paper the effect of tie wire in lap spliced bars is investigated by experiment. The variables considered in the beam behaviors are beam dimension, lapped splice length and numbers of tie wire. 3 test pieces having the same variables consist one series and a total of 6 series ar tested. The test results show the beam behavior is not affected by numbers of tie wire but by the manner of tie. It was revealed hat the load bearing capacity of the beam is increased when the tie wire is extended to top bar.

  • PDF

기존 교각의 FRP 원통관을 이용한 내진보강의 실험연구 (The Experimental Study on the Seismic Strengthening Effect of FRP Circular Tube on the Circular Bridge Piers)

  • 황윤국;윤순종;김정호;최영민;박경훈;권태규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.973-978
    • /
    • 2003
  • This paper describes the experimental study on seismic strengthening effect of circular bridge columns with poor lap-splice details using FRP(Fiber Reinforced Plastic) wrapping, The as-built column suffered brittle failure due to the deterioration of lap-spliced longitudinal reinforcement without developing its flexural capacity or any ductility, The strengthening columns using FRP wrapping showed significant improvement in seismic performance due to FRP's confinement effect.

  • PDF

프리캐스트 세그먼트 거더의 비선형거동 특성에 관한 연구 (A Study on Nonlinear Behavior Characteristics of Precast Segmental Gider)

  • 홍성남;고병순;김광수;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.89-92
    • /
    • 2004
  • Precast Segmental method was developed in germany 1950's. This method has been adoptted in long span girder mainly owing to easy construction effect. But, so far, The limit exists that this method is constructed in a portion of span and hard conveyance and foundation. This study was performed to analysis behavior difference of two rectangular section girder, spliced girder that was jointed 5-sliced 0.8m segment and monolithic girder that was produced in one body 4m span.

  • PDF

Experimental study on all-bolted joint in modularized prefabricated steel structure

  • Wu, Zhanjing;Tao, Zhong;Liu, Bei;Zuo, Heng
    • Structural Engineering and Mechanics
    • /
    • 제73권6호
    • /
    • pp.613-620
    • /
    • 2020
  • The research study is focuses on a form of all-bolted joint with the external ring stiffening plate in the prefabricated steel structure. The components are bolted at site after being fabricated in the factory. Six specimens were tested under cyclic loading, and the effects of column axial compression ratio, concrete-filled column, beam flange sub plate, beam web angle cleats, and spliced column on the failure mode, hysteretic behavior and ductility of the joints were analyzed. The results shown that the proposed all-bolted joint with external ring stiffening plate performed high bearing capability, stable inflexibility degradation, high ductility and plump hysteretic curve. The primary failure modes were bucking at beam end, cracking at the variable section of the external ring stiffening plate, and finally welds fracturing between external ring stiffening plate and column wall. The bearing capability of the joints reduced with the axial compression ratio increased. The use of concrete-filled steel tube column can increase the bearing capability of joints. The existence of the beam flange sub plate, and beam web angle cleat improves the energy dissipation, ductility, bearing capacity and original rigidity of the joint, but also increase the stress concentration at the variable section of the external reinforcing ring plate. The proposed joints with spliced column also performed desirable integrity, large bearing capacity, initial stiffness and energy dissipation capacity for engineering application by reasonable design.

마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능 (Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers)

  • 황현종;박홍근;홍건호;김갑득;최세진
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.387-397
    • /
    • 2015
  • 본 연구에서는 시공성 향상을 위해 데크플레이트와 비정질강섬유 콘크리트를 적용하여 현장 무배근 슬래브 시스템을 연구하였다. 제안한 슬래브에서는 온도철근을 강섬유로 대체하였다. 본 연구는 연속슬래브에서 상부 철근이 연속되지 않는 경우 슬래브의 상부 균열 제어를 주로 고려하였다. 실험변수로 비정질강섬유 혼입량, 강섬유 종류, 데크플레이트 종류, 연속구간의 철근 이음을 고려하였으며, 수직하중을 받는 2경간 슬래브를 실험하였다. 슬래브의 균열저항성능을 평가하기 위하여 연속슬래브의 하중에 따른 균열폭을 계측하였다. 실험결과, 상부 이음철근을 사용하지 않더라도 합성슬래브의 높은 휨강성으로 인하여 균열을 억제할 수 있는 것으로 나타났다.

구조물 모니터링을 위한 헤테로 코어형 광센싱 시스템 (Hetero-core Spliced Fiber Optical Sensing System for an Environment Monitoring)

  • 김영복;이권순;와타나베카즈히로;사사키히로유키;최용운
    • 한국해양공학회지
    • /
    • 제21권3호
    • /
    • pp.46-51
    • /
    • 2007
  • A multi-purpose environmental monitoring system has been developed as a commercially available standard using the technique of hetero-core spliced fiber optic sensors, for the purposes of monitoring large-scale structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition, in view of the full-scale operation at actual sites to be monitored. Additionally, the developed system in this work conveniently provides us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. Two channels of optical fiber line were monitored in each channel, three displacement sensor modules were connected in series, in order to examine the performance to a pseudo-cracking experiment in the outdoor situation and to clarify temperature influences an the system, in terms of the coupling of optical connectors and the OTDR stability. The results from the pseudo-cracking experiment agreed with the actual cracks, by means of calculation, based an the detected displacement values and their geometrical arrangement of the used sensor modules. The temperature change, ranging from 10 to $20^{\circ}C$ resulting from the 10-days free running operation, was found to influence the system stability of ${\pm}10{\mu}m$, primarily due to the coupling instability of the used optical connectors. It was found that fusion splicing, rather than the use of connectors, reduced the fluctuation dawn to ${\pm}2{\mu}m$. The specification and performance of various option modules have been demonstrated to show the capability of inspecting various physical quantities by use of the single system, which would be suitable for multi-purpose environmental monitoring.