• 제목/요약/키워드: Spinal fusion with instrumentation

검색결과 36건 처리시간 0.025초

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

Anterior Dislodgement of a Fusion Cage after Transforaminal Lumbar Interbody Fusion for the Treatment of Isthmic Spondylolisthesis

  • Oh, Hyeong Seok;Lee, Sang-Ho;Hong, Soon-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권2호
    • /
    • pp.128-131
    • /
    • 2013
  • Transforaminal lumbar interbody fusion (TLIF) is commonly used procedure for spinal fusion. However, there are no reports describing anterior cage dislodgement after surgery. This report is a rare case of anterior dislodgement of fusion cage after TLIF for the treatment of isthmic spondylolisthesis with lumbosacral transitional vertebra (LSTV). A 51-year-old man underwent TLIF at L4-5 with posterior instrumentation for the treatment of grade 1 isthmic spondylolisthesis with LSTV. At 7 weeks postoperatively, imaging studies demonstrated that banana-shaped cage migrated anteriorly and anterolisthesis recurred at the index level with pseudoarthrosis. The cage was removed and exchanged by new cage through anterior approach, and screws were replaced with larger size ones and cement augmentation was added. At postoperative 2 days of revision surgery, computed tomography (CT) showed fracture on lateral pedicle and body wall of L5 vertebra. He underwent surgery again for paraspinal decompression at L4-5 and extension of instrumentation to S1 vertebra. His back and leg pains improved significantly after final revision surgery and symptom relief was maintained during follow-up period. At 6 months follow-up, CT images showed solid fusion at L4-5 level. Careful cage selection for TLIF must be done for treatment of spondylolisthesis accompanied with deformed LSTV, especially when reduction will be attempted. Banana-shaped cage should be positioned anteriorly, but anterior dislodgement of cage and reduction failure may occur in case of a highly unstable spine. Revision surgery for the treatment of an anteriorly dislodged cage may be effectively performed using an anterior approach.

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

Accuracy of Freehand versus Navigated Thoracolumbar Pedicle Screw Placement in Patients with Metastatic Tumors of the Spine

  • De La Garza Ramos, Rafael;Echt, Murray;Benton, Joshua A.;Gelfand, Yaroslav;Longo, Michael;Yanamadala, Vijay;Yassari, Reza
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권6호
    • /
    • pp.777-783
    • /
    • 2020
  • Objective : To compare the accuracy and breach rates of freehand (FH) versus navigated (NV) pedicle screws in the thoracic and lumbar spine in patients with metastatic spinal tumors. Methods : A retrospective review of adult patients who underwent pedicle screw fixation in the thoracic or lumbar spine for metastatic spinal tumors between 2012 and 2018 was conducted. Breaches were assessed based on the Gertzbein and Robbins classification and only screws placed >4 mm outside of the pedicle wall (lateral or medial) were considered breached. Results : A total of 62 patients received 547 pedicle screws (average 8 per patient) - 34 patients received 298 pedicle screws in the FH group and 28 patients received 249 screws in the NV group. There were 40/547 breaches, corresponding to a breach and accuracy rate of 7.3% and 92.7%, respectively. The breach rate was 9.7% in the FH group and 4.4% in the NV group (chi-squared test, p=0.017); this corresponded to an accuracy rate of 90.3% and 95.6%, respectively. Only one patient from the overall cohort (in the FH group) required revision surgery due to a medial breach abutting the spinal cord (1.6% of all patients; 2.9% of FH patients); no patient suffered organ, vessel, or neurological injury from screw breaches. Conclusion : Navigated pedicle screw placement in patients with metastatic spinal tumors has a significantly higher radiographic accuracy compared to the FH technique. However, the revision surgery was low and no patient suffered from clinically-relevant breach. Navigation also offers the advantage of real-time localization of spinal tumors and aids in targeting and resection of these lesions.

Expandable Cage for Cervical Spine Reconstruction

  • Zhang, Ho-Yeol;Thongtrangan, Issada;Le, Hoang;Park, Jon;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권6호
    • /
    • pp.435-441
    • /
    • 2005
  • Objective : Expandable cage used for spinal reconstruction after corpectomy has several advantages over nonexpendable cages. Here we present our clinical experience with the use of this cage after anterior column corpectomy with an average of one year follow up. Methods : Ten patients underwent expandable cage reconstruction of the anterior column after single-level or multilevel corpectomy for various cervical spinal disorders. Anterior plating with or without additional posterior instrumentation were performed in all patients. Functional outcomes, complications, and radiographic outcomes were determined. Results : There was no cage-related complication. Functionally, neurological examination revealed improvement in 7 of 10 patients and no patient had neurological deterioration after the surgery. Immediate stability was achieved and maintained throughout the period of follow-up. There was minimal subsidence [<2mm] noticeable in three of the cases that underwent a two-level corpectomy. Subsidence was noted in osteoporotic patients and patients undergoing multi-level corpectomies. Average pre-operative kyphotic angle was 9 degrees. This was corrected to an average of 5.4 degrees in lordosis postoperatively. Conclusion : In conclusion, expandable cages are safe and effective devices for vertebral body replacement after cervical corpectomy when used in combination with anterior plating with or without additional posterior stabilization. The advantages of using expandable cages include its ability to easily accommodate itself into the corpectomy defect, its ability to tightly purchase into the end plates after expansion and thus minimizing the potential for migration, and finally, its ability to correct kyphosis deformity via its in vivo expansion properties.

Usefulness of Oblique Lateral Interbody Fusion at L5-S1 Level Compared to Transforaminal Lumbar Interbody Fusion

  • Mun, Hah Yong;Ko, Myeong Jin;Kim, Young Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권6호
    • /
    • pp.723-729
    • /
    • 2020
  • Objective : The use of oblique lateral interbody fusion at the L5-S1 level (OLIF51) is increasing, but no study has directly compared OLIF51 and transforaminal lumbar interbody fusion (TLIF) at the L5-S1 level. We evaluated the usefulness of OLIF51 by comparing clinical and radiologic outcomes with those of TLIF at the same L5-S1 level. Methods : We retrospectively reviewed and compared 74 patients who underwent OLIF51 (OLIF51 group) and 74 who underwent TLIF at the L5-S1 level (TLIF51 group). Clinical outcomes were assessed with the visual analogue scale for back pain and leg pain and the Oswestry Disability Index. Mean disc height (MDH), foraminal height (FH), disc angle (DA), fusion rate, and subsidence rate were measured for radiologic outcomes. Results : The OLIF51 group used significantly higher, wider, and larger-angled cages than the TLIF51 group (p<0.001). The postoperative MDH and FH were significantly greater in the OLIF51 group than in the TLIF51 group (p<0.001). The postoperative DA was significantly larger in the OLIF51 group than in the TLIF51 group by more than 10º (p<0.001). The fusion rate was 81.1% and 87.8% at postoperative 6 months in the OLIF51 and TLIF51 groups, respectively, and the TLIF51 group showed a higher fusion rate (p<0.05). The subsidence rate was 16.2% and 25.3% in the OLIF51 and TLIF51 groups, respectively, and the OLIF51 group showed a lower subsidence rate (p<0.05). Conclusion : OLIF51 was more effective for the indirect decompression of foraminal stenosis, providing strong mechanical support with a larger cage, and making a greater lordotic angle with a high-angle cage than with TLIF.

Surgical Treatment of Craniovertebral Junction Instability : Clinical Outcomes and Effectiveness in Personal Experience

  • Song, Gyo-Chang;Cho, Kyoung-Suok;Yoo, Do-Sung;Huh, Pil-Woo;Lee, Sang-Bok
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권1호
    • /
    • pp.37-45
    • /
    • 2010
  • Objective : Craniovertebral junction (CVJ) consists of the occipital bone that surrounds the foramen magnum, the atlas and the axis vertebrae. The mortality and morbidity is high for irreducible CVJ lesion with cervico-medullary compression. In a clinical retrospective study, the authors reviewed clinical and radiographic results of occipitocervical fusion using a various methods in 32 patients with CVJ instability. Methods : Thirty-two CVJ lesions (18 male and 14 female) were treated in our department for 12 years. Instability resulted from trauma (14 cases), rheumatoid arthritis (8 cases), assimilation of atlas (4 cases), tumor (2 cases), basilar invagination (2 cases) and miscellaneous (2 cases). Thirty-two patients were internally fixed with 7 anterior and posterior decompression with occipitocervical fusion, 15 posterior decompression and occipitocervical fusion with wire-rod, 5 C1-2 transarticular screw fixation, and 5 C1 lateral mass-C2 transpedicular screw. Outcome (mean follow-up period, 38 months) was based on clinical and radiographic review. The clinical outcome was assessed by Japanese Orthopedic Association (JOA) score. Results : Nine neurologically intact patients remained same after surgery. Among 23 patients with cervical myelopathy, clinical improvement was noted in 18 cases (78.3%). One patient died 2 months after the surgery because of pneumonia and sepsis. Fusion was achieved in 27 patients (93%) at last follow-up. No patient developed evidence of new, recurrent, or progressive instability. Conclusion : The authors conclude that early occipitocervical fusion to be recommended in case of reducible CVJ lesion and the appropriate decompression and occipitocervical fusion are recommended in case of irreducible craniovertebral junction lesion.

흉요추 방출성 압박골절의 Z-plate를 이용한 고정술후 추적검사 결과 (Follow-up Results of Z-plate Fixation in the Thoracolumbar Burst Fracture)

  • 심병수;김근수;이정청
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권6호
    • /
    • pp.763-771
    • /
    • 2000
  • Objectives : Thoracolumbar burst fractures(TBLF) result in not only compressive deformity of vertebral body but also spinal cord compression by bony fragments. Many thoracolumbar burst fractures demand both anterior decompression and intervertebral fusion. Most of spinal surgeons use anterior instrumentation for anteior intervertebral bony fusion. The use of Z-plate has been increased recently, however there has been only a few reports regarding its clinical long-term strength. We studied nineteen patients with TBLF to find out the long-term stability of Z-plate. Methods : We have operated 19 patients from March 1996 to August 1998. They were treated with anterior decompression through either a transthoracic, retroperitoneal extrapleural or retroperitoneal approach. Retropulsed bony fragments were removed completely by corpectomy. Iliac bone graft was used for interbody fusion in all of the cases. They were evaluated by plain X-ray films including flexion and extention lateral films. Cobbs angle was used to evaluate kyphotic and lateral wedging deformity. Results : Burst fractured sites were T11 in two, three T12, nine L1, and five L2. Mean follow-up duration was fifteen months. Preoperative average kyphotic angle was 23.7 degree. Immediate postoperative kyphotic angle was 10.2 degree. Follow-up resluts of average kyphotic angles revealed 14 degrees. Four patients(21%), including two spinal 3-column injury, showed increasement of kyphotic angle more than 5 degree or breakage of intrumentation. Two patients showed the difference of kyphotic angle more than 3 degree. Five patients(26%) revealed lateral wedging deformity more than 3 degrees. Postoperative complications were two meralgia parestheticas, one pulmonary atelectasis and two donor site infections. Four of the eight patients, who initially showed incomplete spinal cord deficits, were nerologically improved by Frankel's grade. Conclusion : Z-plate fixation and iliac bone graft after anterior decompression in thoracolumbar burst fractures is a safe and easy method. Immediate postoperative results revealed excellent correction of posttraumatic kyphosis, but long-term follow-up evalution showed insufficient strength. Therefore we believe that use of Z-plate should be carefully decided, especially in the case of large lumbar fracture or 3-column injury.

  • PDF

Association between Asymptomatic Urinary Tract Infection and Postoperative Spine Infection in Elderly Women : A Retrospective Analysis Study

  • Lee, Seung-Eun;Kim, Kyoung-Tae;Park, Yong-Sook;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권4호
    • /
    • pp.265-270
    • /
    • 2010
  • Objective : The purpose of this study is to identify the relationship between asymptomatic urinary tract infection (aUTI) and postoperative spine infection. Methods : A retrospective review was done in 355 women more than 65 years old who had undergone laminectomy and/or discectomy, and spinal fusion, between January 2004 and December 2008. Previously postulated risk factors (i.e., instrumentation, diabetes, prior corticosteroid therapy, previous spinal surgery, and smoking) were investigated. Furthermore, we added aUTI that was not previously considered. Results : Among 355 patients, 42 met the criteria for aUTI (Bacteriuria ${\geq}\;10^5\;CFU/mL$ and no associated symptoms). A postoperative spine infection was evident in 15 of 355 patients. Of the previously described risk factors, multi-levels (p<0.05), instrumentation (p<0.05) and diabetes (p<0.05) were proven risk factors, whereas aUTI (p>0.05) was not statistically significant. However, aUTI with Foley catheterization was statistically significant when Foley catheterization was added as a variable to the all existing risk factors. Conclusion : aUTI is not rare in elderly women admitted to the hospital for lumbar spine surgery. The results of this study suggest that aUTI with Foley catheterization may be considered a risk factor for postoperative spine infection in elderly women. Therefore, we would consider treating aUTI before operating on elderly women who will need Foley catheterization.

경추에 발생한 거대 세포종 - 증례 보고 - (Giant Cell Tumor of the Cervical Spine - Case Report -)

  • 안기찬;정경칠;김윤준
    • 대한골관절종양학회지
    • /
    • 제12권1호
    • /
    • pp.57-62
    • /
    • 2006
  • 척추의 거대 세포종은 진단이 어려운 경우가 많고, 고도의 악성도로 인해서 수술이 불가능한 경우가 많다. 척추의 거대 세포종은 높은 재발율과 함께 척수의 기계적 압박 가능성으로 인해 방사선 치료가 근간이었으나, 최근에는 근치적 절제술과 함께 기구를 이용한 전후방 고정술을 시행 하여 좋은 결과를 보고 하고있다. 본 정형외과학교실에서는 경부 동통을 유발하며 제3경추를 침범한 거대세포종에 대해서 근치적 절제술과 함께 후방 기기술을 통한 융합을 시행 하였으며, 추시 관찰상 우수한 치료 결과를 보였기에 문헌 고찰과 함께 보고하는 바이다.

  • PDF