• Title/Summary/Keyword: Spin-echo image

Search Result 96, Processing Time 0.028 seconds

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression (발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법)

  • Cho, Kyung Eun;Yoon, Choon-Sik;Song, Ho-Taek;Lee, Young Han;Lim, Daekeon;Suh, Jin-Suck;Kim, Sungjun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.110-122
    • /
    • 2013
  • Purpose : To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression. Materials and Methods: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher's exact test and Pearson's chi-squared test were used to compare the ligament traceability. Results: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA SPAIR showed the higher CR only in F-T (p = 0.04), whereas VISTA showed higher CR in f-T (p = 0.005), f-C (p = 0.005) and f-L (p = 0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes. Conclusion: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament.

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Differential Diagnosis of Bicornuate and Septate Uterus : Is Comparison of Septal Signal Intensity on MR Image Useful\ulcorner (양각 자궁과 중격 자궁의 감멸 진단: 자기공명영상에서 자궁 격막 신호 강도의 비교는 유용한가\ulcorner)

  • 김종철;변재영;백승연
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.107-112
    • /
    • 2000
  • Purpose : To evaluate the usefulness of comparison of the signal intensity of uterine septum in the differential diagnosis of bicornuate and septate uterus on magnetic resonance (MR) imaging. Materials and methods : Preoperative MR imaging findings of surgically proven 5 bicornuate and 6 septate uteri were retrospectively analyzed. Because preoperative differential diagnosis of both was possible in all cases in terms of the intercornual distance, external contour of uterine fungus, and divergent angle of two uterine cavities, these criteria were excluded in this study. The signal intensity of uterine septum in patients with bicornuate and septate uterus was analyzed on T1-weighted and fast spin echo T2-weighted images obtained in the axial and coronal planes, using a 1.5-T MR scanner. The signal intensity of uterine septum especially on T2-weighted images was compared with that of myometrium or junctional zone. Results : The signal intensity of uterine septum in patients with bicornuate uterus (n=5) and septate uterus (n=6) was similar to that of myometrium in all cases on T1-weighted images. The septum of bicornuate uterus (n=5) on fast spin echo T2-weighted images was isointense with myometrium in three and hypointense in two cases. The uterine septum of septate uterus (n=6) on T2-weighted images was isointense with myometrium in two, hypointense in two, and isointense with or more hypointense than junctional zone in two cases. No patient showed different signal intensity between upper and lower uterine septum. Conclusion : Because the MR signal intensity of the uterine septum in bicornuate or septate uterus is variable, it should not be used alone in the differential diagnosis of them. In these clinically important differentiation, therefore, comprehensive analysis of MR findings in terms of the external contour of uterine fundus, intercornual distance, divergent angle of two uterine cavities, in addition to the signal intensity of the uterine septum, should be considered.

  • PDF

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

MR Imaging Findings of Uterine Cervical Adenocarcinoma (자궁경부 선암종의 자기공명영상 소견)

  • 김종철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • Purpose : Because adenocarcinomas of the uterine cervix have lower 5-year survival rate than squamous cell carcinomas due to early lymph node metastasis and local extension, scrutiny of lymph node metastasis and local extension by radiologic examination is necessary in case of clinically diagnosed or suspected adenocarcinomas. The purpose of this study is to evaluate whether there are specific findings of these tumors, compared with squamous cell carcinomas, through the analysis of magnetic resonance (MR) imaging findings. Materials and Methods : Of 21 pathologically proven cervical adenocarcinomas, MR imaging findings of 18 tumors (histologic staging : two Ib, four IIa, two IIb, one IIIa, and one IIIb) were retrospectively analyzed and compared with those of 40 wquamous cell carcinoma in consecutive patients as a control group. T1-wetighted and fast spin echo T2-weighted images were obtained on the axial and sagittal planes, using a 1.5-T MR scanner. The largest diameter, location, signal intensity and degree of contrast enhancement contour, shape and longitudinal extent of the tumor and associated findings on MR image were analyzed. Results : The largest diameters of cervical adenocarcinomas ranged from 0.8 to 4.1 cm(mean, 2.2 cm). Of 18 adenocarcinomas, nine were of endocervical type. All adenocarcinomas were isointense to surrounding cervical stroma on T1-weighted images and hyperintense(homogeneous in ten, inhomogeneous in eight) on fast spin echo T2-weighted images. Adenocarcinomas enhanced on contrast study in all patients (homogeneous in six, inhomogeneous in 12 with hyperintese enhnacing rim in two). Eight adenocarcinomas had smooth contours and ten had irregular ones. The shape of adenocarcinoma was irregular in eight patients, barrel shape in six, papillary/polypod in three, and nodular in one. All adenocarcinomas involved lower half of the uterine cervix and six tumors extended up to the upper half. Pelvic lymph nodes of more than 1.5cm in diameter in two adenocarcinomas pateints and no detectable small pelvic lymph nodes on MR imaging in one patient were pathologically positive. Hydrometra was associated in two adenocarcinomas patients, and hematometra in one patient. Compared with squamous cell carcinomas, more frequent MR findings of endocervical type and barrel shape in cervical adenocarcinomas were statistically significant. Conclusion : Cervical adenocarcinomas had more frequent MR findings of endocervical type and barrel shape, compared with wquamous cell carcinomas. Adenocarcinoma of the uterine cervix may be suspected on MR imaging, when a cervical carcinoma is of barrel shape along the endocervical canal and tends to involve lymth nodes in earlier stages.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

Gadoteridol's Signal Change according to TR, TE Parameters in T1 Image (T1영상에서 TR, TE 매개변수에 따른 Gadoteridol의 신호강도 변화)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Nam, Ki Chang;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, we introduce how to control TR, TE physical MR parameters for managing $H_1$ spin's SI(Signal Intensity) which is combined with gadolinium following administration MR agent in T1 effect for diagnostic usefulness. we used MRI phantom made with 0.5 mol Gadoteridol. This phantom was scanned by FSE sequence with different TR, TE parameters. In this study, to make T1 effect, TR was 200, 250, 300, 350, 400, 450, 500, 550, 600 msec. In addition to, TE was 6.2, 12.4, 18.6, 21.6 msec. The results were as follows ; Each RSP(Reaction Starting Point) was 100, 50, 40, 30 mmol in TE 6.2, 12.4, 18.6, 21.6 msec being irrelevant to TR. In MPSI(Max Peak Signal Intensity), 4 mmol was showed in TR 200 msec while peak signal was decreased to low concentration mol in TR 250-600 msec. In terms of RA(Reaction Area), the highest SI was TE 6.2 msec in TR 200-600msec. According to the study, we are able to recognize it is possible to control enhance rates by managing TR and TE of MR parameters; moreover, we expect that enhanced T1 image in MR clinical field can be performed in a practical way with this quantitative data.

Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging (뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구)

  • Lee, Hoo-Min;Kim, Ham-Gyum;Kong, Seok-Kyo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • The purpose of this research is to seek SPAIR's reversal time (TI) which satisfies two conditions ; maintaining the suppression ability of fat tissue and simultaneously minimizing the inhomogeneity of fat tissue in T2 high-speed spin echo 3.0T magnetic resonance image (MRI) of the brain, and to compare SPAIR with STIR which is fat-suppression technique. The reversal times (TI) of SPAIR protocol are set to 1/2, 1/3, 1/6 and 1/12 of SPAIR TR (420 msec), namely 210 msec (8 people), 140 msec (26 people), 70 msec (26 people) and 35 msec (18 people) and STIR TI is set with 250 msec (26 people). With these parameter sets, we acquired the axis direction 104 images of the brain. In ROI ($50\;mm^2$) of output image, signal intensities of the fatty tissue, the muscular tissue, and the background were measured and the CNRs of fatty tissue and the muscular tissue were calculated. The inhomogeneity of the fatty tissue is SD/mean, where SD is the standard deviation and 'mean' is a average fatty tissue signal. Consequently, SPAIR TI is determined on either 1/3 or 1/6 of TR (420 ms) ; 140 ms or 70 ms. Because the difference of statistics in fat-suppression ability and inhomogeneity of fatty tissue is very small (p < 0.001), Selecting 140 ms seems to be better choice for the image quality. Meanwhile, Comparing SPAIR (TI : 140 ms) with STIR, the fat-suppression is not able to be considered statistically (p < 0.252), but the image quality is able to be considered statistically (p < 0.01). In conclusion, SPAIR is better than STIR in the image quality.

  • PDF