To investigate the visual acuity of the women middle and high school students, the visual acuity test was performed the object and subject methods. The results were as follows; 1. The eye types were 96.7% positive for myopia, 2.5% for emmetropia, and 0.8% for hyperopia, respectively. 2. The abnormal refraction eyes were 61% positive for simple myopia, 35.2% for myopitic compound astigmatism, 3% for myopic simple astigmatism, and 0.8% for simple presbyopia, respectively. 3. The asix of astigmatism were 95% positive for irregular astigmatism axis, 3% for regular astigmatism axis, and 2% for oblique astigmatism axis, respectively. 4. On the total myopic spheric power, the -0.50
Purpose: This study is aimed at finding the conditions of ametropia of adults in the Philippines and the South Korean. Methods: The study objects were 7,695(15,390 eyes) Koreans and 2,256(4,512 eyes) Philippines who visited optic clinics and took refraction test. The distributions of their hypermetropias and myopias about astigmatisms were examined, using the method of equivalent spherical power. When astigmatisms were marked in S-C, cylinder lens diopter and astigmatism axis, presbyopic additions and pupillary distances were analyzed by comparison respectively. Results: Among ametropias of Koreans myopias and hypermetropias were 93.69% and 6.31% respectively and about ametropias of Philippines myopia and hypermetropias were 73.43% and 26.57% respectively. As for spherical equivalent power about Koreans, the results showed that Koreans marked -3.352 D about myopia and Philippines marked -2.213 D about it. There is a gap of -1.139 D between them. About hypermetropia Koreans marked 1.147 D and Philippines, 1.251 D and their gap is 0.104 D. As for ametropia of Koreans there is 49.86% in middle myopia, 32.28% about low myopia, 11.55% about high myopia, and 5.54% about low hypermetropia, 0.75% about middle hypermetropia. As for it about Philippines there is 44.53% in low myopia, 25.11% about middle myopia, 3.79% high myopia and 23.03% low hypermetropia, and 3.51% low hypermetropia respectively. As for cylinder lens there is differences of 0.194 D and 0.22 D between Korean and Philippine for both sexes. Totally Koreans have higher cylinders of 0.175 D than Philippines. As for astigmatism, Koreans have direct astigmatism, inverse astigmatism, and oblique astigmatism in their suffering sequence. As for Philippines, they have direct astigmatism, inverse stigmatism, and oblique astigmatism in their abnormal sequence, and they have higher oblique stigmatism than Koreans. As for presbyopic addition, Philippines have higher distributions than Koreans, and 0.296 D is higher in average. As for pupillary distance, Koreans have longer distance of 0.97 mm in man and 0.63 mm in women than Philippines. Conclusions: As for ametropia, Koreans and Philippines have more myopias than hypermetropias, but Philippines have more rates of hypermetropias than Koreans. And Philippines have more presbyopic additions. Koreans have higher morbidity of inverse astigmatism, and Philippines have higher morbidity of oblique astigmatism comparatively. As for pupillary distance, Koreans have longer length in the body characteristics. This shows that geographical circumstances have much to do with refraction conditions of eyes.
The results of effective irradiation swelling in a wide range of burnup levels are numerically obtained for an inert matrix fuel, which are verified with DART model. The fission gas swelling of fuel particles is calculated with a mechanistic model, which depends on the external hydrostatic pressure. Additionally, irradiation and thermal creep effects are included in the inert matrix. The effects of matrix creep strains, external hydrostatic pressure and temperature on the effective irradiation swelling are investigated. The research results indicate that (1) the above effects are coupled with each other; (2) the matrix creep effects at high temperatures should be involved; and (3) ranged from 0 to 300 MPa, a remarkable dependence of external hydrostatic pressure can be found. Furthermore, an explicit multi-variable mathematic model is established for the effective irradiation swelling, as a function of particle volume fraction, temperature, external hydrostatic pressure and fuel particle fission density, which can well reproduce the finite element results. The mathematic model for the current volume fraction of fuel particles can help establish other effective performance models.
Purpose: To research the study of abnormal refraction eye on women population of university students in South - East Korea. Methods: Between March 2007 and October 2007, the refraction test of eye glasses wearer was evaluated on women population (367 students, aged 19~22 years) of university in living on Kyung-Nam and Pusan province. Data was analysed with T-test. Results: On the abnormal refraction status, Compound Myopic Astigmatism was 76.72%, simple myopia was 10.90%, mixed astigmatism was 6.27%, respectively. On the prevalence of myopic power, low was 59.57%, moderate was 24.93%, high was 15.49%, respectively. On the myopic equivalent power, the right eye had more increase to compare to left eye. but these was not a statically significant correlation (p<0.5) between the right and left eyes. On the anisometropia of spherical equivalents and cylinder power, most subjects was under 1.0 diopter. On the other hand, the type of astigmatic axis was with-the rule (70.79%), against -the rule (18.41%), and oblique (10.80%). Conclusions: This study identify that the refraction status of abnormal refraction eye on women population in university students in South-East Korea have been more increased prevalence the myopia and astigmatism.
The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.
This research reviewed that 83 male subjects. 89 female subjects of middle and high school visited D Optical shop at the downtown of Daegu more than twice from January, 1999 to January, 2003 and obtained the following results by using the visual acuity prescription of them for which D Optical shop was keeping. 1. The classification of correction power for 190 myopia eyes was examined (87 male eyes, 103 female eyes) showed 89 eyes(46.82%) between $0.25D{\leq}3.00D$, 86 eyes(45.26%) between $3.25D{\leq}6.00D$, 15 eyes(7.89%) for over 6.25D. 2. The kind of 154 astigmatism subjects(79 male eyes, 75 female eyes) was direct astigmatism 83.77%, reverse astigmatism 11.69%, oblique astigmatism 4.55%. The cylindrical correction power for astigmatic eyes was 61 eyes(39.61%) between $0.25D{\leq}0.50D$, 60 eyes(38.96%) between 0.50D<1.00D, 121 eyes(78.57%) for less than 1.06D, 6 eyes(0.65%) for over 3.00D. 3. The variation of spherical power showed 161 eyes(46.80%) between $0.00D{\leq}0.50D$, 109 eyes(31.69%) between $0.51D{\leq}1.00D$, 17 eyes(4.94%) for over 2.01D variation. 4. The variation of astigmatic power showed 92 eyes(59.74%) between $0.00D{\leq}0.50D$, 39 eyes(25.32%) between $0.26D{\leq}0.50D$, 10eyes (6.49%) between $0.51D{\leq}0.75D$, 13 eyes(8.44 %) for over 0.76D astigmatic variation. 5. The variation of equivalent spherical power showed 137 eyes(39.83%) between $0.00D{\leq}0.50D$, 126 eyes(36.63%) between $0.51D{\leq}1.00D$, 40 eyes(11.63%) between $1.01D{\leq}1.50D$, 21 eyes(6.10%) between $1.51D{\leq}2.00D$, 20 eyes(5.81%) for over 2.01D variation.
Transactions of the Korean Society of Mechanical Engineers A
/
v.35
no.5
/
pp.549-554
/
2011
Recently, technical advances have been made in high efficiency gas turbine power plants. In domestic gas turbine facilities, the material properties of the blade and vane are degraded by the daily start-stop operations arising from the thermo mechanical cycle. We surveyed the time dependent degradation of the HP blade and vane to gather basic data for life assessment and damage analysis. The EOH(equivalent operating hours) of the blades were 23,686, 27,909, and 52,859 and the EOH of the vanes were 28,714 and 52,859, respectively. With increased operating hours, the shape of the primary ${\gamma}$' precipitate transformed from cubic to spherical, and its average size also increased. The leading edge area of the blades and the center of the vanes had the worst morphology, and this tendency agrees with the microhardness results. The thickness of the thermally grown oxide at the outer surface of the bond coat increased with increased operating hours.
Lee, Hun;Kang, David Sung Yong;Ha, Byoung Jin;Choi, Jin Young;Kim, Eung Kweon;Seo, Kyoung Yul;Kim, Tae-im
Yonsei Medical Journal
/
v.59
no.9
/
pp.1115-1122
/
2018
Purpose: To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. Materials and Methods: In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. Results: This study included 217 eyes of 118 participants (20-81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20-44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased CorvisIOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20-44 years, and over 44 years). Conclusion: We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.
Park, Mijung;Ahn, Young Joo;Kim, Soo Jung;You, Jiyoung;Park, Kyung Eun;Kim, So Ra
Journal of Korean Ophthalmic Optics Society
/
v.19
no.2
/
pp.253-260
/
2014
Purpose: The present study was conducted to investigate whether near work with smartphone could induce the change of accommodative function. Methods: Total 63 subjects(26 male and 37 female) in their 20s were firstly examined their visual functions related to accommodation and uncorrected spherical equivalent power as the control. After that, the subjects were asked to read a book for 30 min and sequentially watch a movie on smartphone for the same time after 30 min-break under the indoor light or as it was in the reverse order to avoid time-ordered effect. Their accommodative functions, 1) accommodative amplitude, 2) accommodative facility, 3) relative positive/negative accommodation, and 4) accommodative lag and their uncorrected spherical equivalent power were examined again following each task and compared with the control values. Results: The monocular accommodative amplitude was significantly decreased after smartphone watching compared with it after reading. The monocular and binocular accommodative facilities were tended to reduce after smartphone watching and book reading but were not significantly different. Neither significant change in positive relative accommodation was determined after smartphone watching nor book reading. Negative relative accommodation after smartphone watching was almost unchanged unlike reading a book. The accommodative lag after smartphone work was significantly higher than after book reading. Conclusions: The near work with a smartphone for 30 min induced the change of some accommodative functions, which was significantly greater than when reading under the same working environment.
Choi, Hae Jung;Cha, Jung Won;Park, Moon Chan;Chen, Ko Hsein
Journal of Korean Ophthalmic Optics Society
/
v.3
no.1
/
pp.103-113
/
1998
Until now, the study of eye refractive error examination for high school students are a few report that in Korea. In particular, there is few report about the visual power for same group during several years. We compared the study of refractive error done this year with that reported three years ago at the same high school. From the these data, the distribution of ammetropia was investigated. The study of refractive error for high school students was also compared with those reported before for the Adults and the middle school student. When the visual power is refered to spherical equivalent, the 36% of the whole students examined above had emmetropia and the other part of them fumed out to be ammetropia which is classify to 60.6% belonged to myopia and 4.4% belonged to hyperpia. The ratio of myopia for this year students is increased in comparision with the students in 1995. The ratio of emmetropia for this year students is 7.4% higher, and the ratio of myopia for this year students is 4% higher, but the ratio of hyperopia is very lower than that for the adults in 1997. In the kind of refractive error, it is classified that a simple myopia is shown to highest ratio as a 28.6% of 1212 eyes examined, a compound myopic astigmatism to the next high ratio as a 22.4%, a simple myopic astigmatism as 14.4%, a simple hyperopic astigmatism as 3.1%, a mixed astigmatism as a 1.7%, a simple astigmatism as 1.2%, a compound hyperopic astigmatism as 1.2%, respectively. The percentage of an astigmatism is a 76.7% of total eyes examined if Cyl-0.25 Dptr is included to an astigmatism. On the other hand, The percentage of an astigmatism is a 45.6% of total eyes examined if Cyl-0.25 Dptr is excluded to an astigmatism. In the kind of astigmatism, the number of students had an astigmatism with the rule is about 4.5 times than that of astigmatism against the rule. From the result of comparision the right eye with the left eye, the right eye of the students had more a myopic refractive error than the left eye, which is same as adults' case, there is no difference in a refractive error between the boy students and the girl students.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.