22.9 kV XLPE 전력케이블에서 부분방전 측정을 위한 Planar Patch Sensor 설계 및 제작 연구 (A Study on the Design and Fabrication for Partial Discharge Measurement in 22.9kV XLPE Power Cable using Planar Patch Sensor)

  • 임광진;양상현;;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.265-266
    • /
    • 2008
  • The objective of this paper is to effectively detect partial discharges in XLPE power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar patch types for XLPE power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Patch Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

항공 계기착륙 디지털 송수신 모듈 설계 (Design of Digital Transmitter and Receiver Modules in ILS)

  • 최종호
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.264-271
    • /
    • 2011
  • 항공기의 계기착륙을 유도하는 시스템인 ILS(Instrument Landing System)는 1947년 ICAO(International Civil Aviation Organization)에서 국제표준으로 채택되어 현재는 상용시스템으로 출시되고 있다. 본 논문에서는 통합형 ILS 디지털 송수신 모듈의 설계방법을 제안하였다. 새롭게 제안한 것은 FPGA를 이용한 디지털 이중 AM 변복조기, 샘플링 클럭 생성을 위한 DDS(Direct Digital Synthesizer), DDC(Digital Down converter) 구조의 복조기, DSP 칩을 이용한 AM 스펙트럼 분석기의 디지털 설계 기법이다. 제안한 설계 방법의 유용성을 모듈 개발 및 실험을 통해 확인한 결과, 성능이 우수한 상용 시스템으로의 활용이 가능함을 확인하였다.

저온 동시소성 세라믹을 이용한 적층형 VCO의 설계 및 제작 (Design and Manufacture of Multi-layer VCO by LTCC)

  • 박귀남;이헌용;김지균;송진형;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.291-294
    • /
    • 2003
  • The circuit substrate was made from the Low Temperature Cofired Ceramics(LTCC) that a $\varepsilon_\gamma$ was 7.8. Accumulated Varactor and the low noise transistor which were a Surface Mount Device-type element on LTCC substrate. Let passive element composed R, L, C with strip-line of three dimension in the multilayer substrate circuit inside, and one structure accumulate band-pass filter, resonator, a bias line, a matching circuit, and made it. Used Screen-Print process, and made Strip-line resonator. A design produced and multilayer-type VCO(Voltage Controlled Oscillator), and recognized a characteristic with the Spectrum Analyzer which was measurement equipment. Measured multilayer structure VCO is oscillation frequency 1292[MHz], oscillation output -28.38[dBm], hamonics characteristic -45[dBc] in control voltage 1.5[V], A phase noise is -68.22[dBc/Hz] in 100 KHz offset frequency. The oscillation frequency variable characteristic showed 30[MHz/V] characteristic, and consumption electric current is approximately 10[mA].

  • PDF

둥근형 무전극 형광램프의 자계 분포 특성 (Magnetic Field Distribution Characteristics of Ring-Shaped Electrodeless Fluorescent Lamp)

  • 최용성;조재철;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.53-57
    • /
    • 2006
  • In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 kHz and some specific conditions. The electromagnetic field in the ferrite core was shown to be high and symmetric. An LS-100 luminance meter and a Darsa-2000 spectrum analyzer were used in the experiment. According to data on the lamp tested using high magnetic field ferrite, the optical and thermal wave fields were shown to be high around the ring-shaped electrodeless fluorescent lamp. The optical or light field was high at the center of the bulb rather than around the ferrite core. The light conditions of the bulb were assumed to be complex, depending on the condition of the filler gas, the volume of the bulb, and the frequency of the inverter. Our results have shown coupling between the gas plasma and the field of the light emitted to be nonlinear.

  • PDF

Bioimpedance Changes in Rats with CCl4-Induced Liver Fibrosis

  • Heo, Jeong;Jung, Dong-Keun
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.71-76
    • /
    • 2011
  • To characterize the relationship between the stage of hepatic fibrosis and bioimpedance, several electric parameters were estimated in rats with $CCl_4$-induced liver fibrosis. Thirty three Sprague-Dawley rats were intraperitoneally injected with a $CCl_4$-mineral oil mixture (1:1, 0.2 mL/100 g) twice a week for 8 weeks. The resistance(R), reactance(X), impedance(Z), and dissipation factor(D) between 1 kHz and 100 kHz were then evaluated in the livers of the rats under pentobarbital anesthesia using an HP4294A Impedance Analyzer. The rats were killed 2, 4, 6, and 8 weeks later, and their livers were classified in accordance with Ishak's scoring system. R, X, and Z changed in accordance with the progression of hepatic fibrosis and the changes were greater at lower frequencies than at higher frequencies. In comparison, the D spectrum was biphasic; D increased initially then decreased with increasing frequency. All of the parameters(R, X, Z, and D) changed in accordance with the stage of fibrosis in the livers, but D changed specifically with the progression of fibrosis. These results indicate that hepatic fibrosis may be evaluated by determining the changes in D.

친환경 가스 중 전극과 고체절연체의 불량접촉에 관한 절연진단연구 (Study on Insulation Diagnosis of Poor Contact between Electrode and Solid Insulator in Eco-Gas)

  • 임동영;최은혁;배성우;최상태;이광식;최병주
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.97-103
    • /
    • 2015
  • This paper presents the characteristics of partial discharge and radiated electromagnetic waves in the existence of a poor contact for the insulation diagnosis of eco-friendly power equipment. AC surface discharge experiment was conducted to simulate the poor contact between a hive voltage electrode (anode) and a solid insulator in $N_2/O_2$ mixture gas under a non-uniform field. The partial discharge voltage to be measured at 0.3MPa increased with the increase of the poor contact gap and was saturated with the gap. In addition to the partial discharge characteristics, it was verified that the defect of the poor contact can be diagnosed using the radiated electromagnetic waves due to the partial discharge, which measured by a biconical EMC antenna and a spectrum analyzer.

모의 GIS의 전기적 이상에 따른 방사전자파의 특성과 절연진단용 UHF 센서 설계 (Characteristics of Radiated Electromagnetic Waves in Model GIS with Electrical Trouble and Design of Insulted Diagnosis UHF Sensor)

  • 박광서
    • 조명전기설비학회논문지
    • /
    • 제22권5호
    • /
    • pp.47-52
    • /
    • 2008
  • 본 논문에서는 모의 GIS 내부에 도전성 파티클, 미소돌기, 연면방전을 모의함으로 전하의 축적과 전계의 집중이 용이하도록 하여 부분방전을 모의하였다. 이때 부분방전 발생과 진전에 따른 방사전자파를 스펙트럼 분석기와 EMI EMC 측정용 안테나($30{\sim}2,000[MHz]$)를 사용하여 측정 분석하였다. 이러한 결과를 바탕으로 0.3[GHz]에서 1.7[GHz]대역에서 UHF법을 활용한 절연진단이 가능한 UHF 구형 센서를 설계하였다. 이러한 연구결과는 $SF_6$를 사용하는 실제 GIS 및 전력설비의 UHF 절연진단 시스템에 적용 가능한 UHF 진단센서로 활용할 수 있을 것이다.

22.9kV급 지중전력케이블의 부분방전 측정을 위한 평면루프센서 설계 및 제작 연구 (A Study on the Design and Fabrication for Partial Discharge Measurment in 22.9kV Underground Power Cable using Planar Loop Sensor)

  • 신동훈;임광진;;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.210-211
    • /
    • 2007
  • The objective of this paper is to effectively detect partial discharges in underground power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar loop types for underground power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Loop Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

ALA 및 ALA-Methylester의 투여에 따른 종양조직 및 정상조직에의 분포양상에 대한 연구 (Distribution Patterns in the Tumor Tissue and Normal Tissue according to the Administration Methods of ALA and ALA-Methylester)

  • 정필상;정상운;안진철;이상준;윤준식
    • 대한두경부종양학회지
    • /
    • 제19권1호
    • /
    • pp.21-24
    • /
    • 2003
  • Objectives: In this report, we confirmed the distributed pattern of ALA and ALA-methylester in normal and tumor-bearing region. Materials and Methods: ALA and ALA-methylester were administered to nude mouse by intratumoral, subcutaneous and intravenous injection. After injection, the fluorescence in normal and tumor region was measured by LESA (laser electronic spectrum analyzer). Results: The tumor-specificity of ALA and ALA-methylester was shown in the case of intratumoral injection. In all case, the fluorescence caused by ALA and ALA-methylester was maximally increased in 2 hours after injection. Then while the fluorescence level was rapidly decreased to control level in normal region, it was still remained in tumor region. Conclusion: According to this result, The intratumoral injection was more efficient administration method for PDT/PDD than subcutaneous and intravenous injection.

광섬유 브래그 격자 센서의 변형률 감지도 (Strain Sensitivity of Fiber Optic Bragg Grating Sensor)

  • 권일범;최만용;김민수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.237-243
    • /
    • 1999
  • Recently, there has been considerable interest in the development of fiber-optic sensors based on fiber Bragg gratings (FBGs), which can be made into Ge-doped fiber's core by UV phase mask or holographic methods. A good sensitivity and small size of this sensor make it an ideal candidate for distributed sensing in smart structures or other structural monitoring applications. In this study, fiber optic Bragg grating sensor, which could be applied to measure the absolute strains, was constructed and the strain sensitivity of this sensor was investigated in order to apply to the structural health monitoring. Fiber Fabry-Perot (FFP) filter has been used to detect the optical signals instead of optical spectrum analyzer. It has been convenient to determine the structural strains from the output signal of FBGs. The fiber optic Bragg grating sensor was attached on the aluminum beam near the electrical strain gage to measure the same strain. The relationship between strain and fiber signal was linearly fitted. The strain sensitivity of the fiber optic Bragg grating sensor was determined as $l.57{\mu}{\varepsilon}/{\mu}sec$ from the aluminum beam test.

  • PDF