• Title/Summary/Keyword: Spectrum Analyzer

Search Result 259, Processing Time 0.019 seconds

The Analysis of Acoustic Emission Spectra in a 36 kHz Sonoreactor (36kHz 초음파 반응기에서의 원주파수 및 파생주파수의 음압 분포 분석)

  • Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.128-134
    • /
    • 2016
  • Acoustic emission spectra was analyzed to investigate the distribution of sound pressure in a 36 kHz sonoreactor. The sound pressure of fundamental frequency (f: 36 kHz), harmonics (2f: 72 kHz, 3f: 108 kHz, 4f: 144 kHz, 5f: 180 kHz, 6f: 216 kHz), and subharmonics (1.5f: 54 kHz, 2.5f: 90 kHz, 3.5f: 126 kHz, 4.5f: 162 kHz, 5.5f: 198 kHz, 6.5f; 234 kHz) was measured at every 5 cm from the ultrasonic transducer using a hydrophone and a spectrum analyzer. It was revealed that the input power of ultrasound, the application of mechanical mixing, and the concentration of SDS affected the sound pressure distributions of the fundamental frequency and total detected frequencies frequencies significantly. Moreover a linear relationship was found between the average total sound pressure and the degree of sonochemical oxidation while there was no significant linear relationship between the average sound pressure of fundamental frequency and the degree of sonochemical oxidation.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

A Generalized Calorie Estimation Algorithm Using 3-Axis Accelerometer

  • Choi, Jee-Hyun;Lee, Jeong-Whan;Shin, Kun-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.301-309
    • /
    • 2006
  • The main purpose of this study is to derive a regression equation that predicts the individual differences in activity energy expenditure (AEE) using accelerometer during different types of activity. Two subject groups were recruited separately in time: One is a homogeneous group of 94 healthy young adults with age ranged from $20\sim35$ yrs. The other subject group has a broad spectrum of physical characteristics in terms of age and fat ratio. 226 adolescents and adults of age ranged from $12\sim57$ yrs and fat ratio from $4.1\sim39.7%$ were in the second group. The wireless 3-axis accelerometers were developed and carefully fixed at the waist belt level. Simultaneously the total calorie expenditure was measured by gas analyzer. Each subject performed walking and running at speeds of 1.5, 3.0, 4.5, 6.0, 6.5, 7.5, and 8.5 km/hr. A generalized sensor-independent regression equation for AEE was derived. The regression equation was developed fur walking and running. The regression coefficients were predicted as functions of physical factors-age, gender, height, and weight with multivariable regression analysis. The generalized calorie estimation equation predicts AEE with correlation coefficient of 0.96 and the average accuracy of the accumulated calorie was $89.6{\pm}7.9%$.

Dynamic Modulus of Three-Layer Boards with Different Furnish and Shelling Ratio

  • Rofii, Muhammad Navis;Prayitno, Tibertius Agus;Suzuki, Shigehiko
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.274-282
    • /
    • 2016
  • This aims of this study were to investigate the relationship between non-destructive evaluation (NDE) and actual bending properties of particleboard, and to predict the bending properties of three-layer particleboard. Three kinds of raw materials, i.e. Hinoki (Chamaecyparis obtusa Endl.) strand, knife-milled Douglas-fir (Pseudotsuga manziesii (Mirb) Franco), and hammer-milled matoa (Pometia spp.) obtained from wooden industry, were utilized as furnish for experimental panel with methylene diphenyl diisocyanate (MDI) resin as binder. The NDE test was conducted by hit sounds using an FFT analyzer according to the spectrum peak of wave frequency, while the static bending test was conducted according to JIS A-5908. The results reveal that the dynamic Young's modulus as an NDE test has a potential for being used to predict the elastic bending of particleboards by a specific equation for adjusting its proper values. The values of NDE and static test are significantly different with a deviation range at 3-20%. The bending stiffness of three-layer particleboards manufactured from different wood species is predictable by observing the bending stiffness of two elements based on the thickness of its layers. The predicted values of bending stiffness and static test are significantly different with a deviation range at 5-24%.

Thermal Emissivity of Nuclear Graphite as a Function of Its Oxidation Degree (1) -Effects of Density, Porosity, and Microstructure-

  • Seo, Seung-Kuk;Roh, Jae-Seung;Kim, Eung-Seon;Chi, Se-Hwan;Kim, Suk-Hwan;Lee, Sang-Woo
    • Carbon letters
    • /
    • v.10 no.3
    • /
    • pp.225-229
    • /
    • 2009
  • Thermal emissivity of commercial nuclear graphites (IG-110, PCEA, IG-430 and NBG-18) following changes in oxidation degrees were examined. Specimens were oxidized to 0%, 5%, and 10% in air flow of 5l/min at $600^{\circ}C$ using a furnace, and the thermal emissivities were measured using an infrared spectrum analyzer. The measuring temperatures for the thermal emissivity were $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$ $500^{\circ}C$. Also density and porosity of the specimens were observed to compare with thermal emissivity. Results showed that emissivity increased with oxidation, and the 10% oxidized NBG-18 showed the highest emissivity (0.890) which value is larger for 24% than the value of as-received specimen. Investigation of factors affecting the emissivity revealed that increases in the surface roughness and porosity due to oxidation were responsible for the increase in emissivity after oxidation.

THE SEA NOISE OF THE MOVING TRAWL NET (예망어구에서 발생되는 수중음에 관한 연구)

  • YOON Gab Dong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 1975
  • The sea noise of moving trawl net was recorded by an underwater tape recorder which was set wireless, and was analyzed by a sound level meter and an octave-band analyzer. The frequency distribution of sea noise of the moving otter trawl net ranged from DC to 5000 Hz, and the dominant frequency zone ranged from 500 Hz to 700 Hz, and the maximum sound pressure is about 22 dB at the otter trawl net. The main sound source of the sea noise from the moving trawl net was found to be sea noise due to the resistance of the ground rope against the sea bottom.

  • PDF

A Study on the Measurement of Vibration Mode Shape using Holographic interferometry (홀로그래픽 간섭법을 이용한 진동모드의 계측에 관한 연구)

  • 김광래
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.130-135
    • /
    • 2000
  • In this study the vibration behavior of the stiffened double cylinder was experimently analyzed. Due to the complex structure of the double cylinder the outside cylinder frequency responses to the exciting forces applied on various posi-tions were analyzed by using spectrum analyzer in conjunction with an accelerometer and the natural frequencies were obtained. The technique of time-averaged holographic interferometry is applied to study the vibration characteristics of outside cylinder with stiffening T frame. The experimental data showed that the T frame had salient effect of damping on the testing structure at most of resonances. however the experimental results also revealed interesting phenomenon. At some particular frequencies the T frame. The experimental data showed that the T frame had salient effect of damping on the testing structure at most of resonances. However the experimental results also revealed interesting phenomenon. At some particular frequencies the T frame seemed to behave as a transmitter. In addition it has been successfully demon-started that optical method such as holographic interferometry is well suited for the identification of mode shapes. They can give us a whole-field non-contact measurement instead of the point-wise measurement by accelerometer in classical modal testing.

  • PDF

A Straightforward Estimation Approach for Determining Parasitic Capacitance of Inductors during High Frequency Operation

  • Kanzi, Khalil;Nafissi, Hanidreza R.;Kanzi, Majid
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.339-353
    • /
    • 2014
  • A straightforward method for optimal determining of a high frequency inductor's parasitic capacitance is presented. The proposed estimation method is based on measuring the inductor's impedance samples over a limited frequency range bordering on the resonance point considering k-dB deviation from the maximum impedance. An optimized solution to k could be obtained by minimizing the root mean squared error between the measured and the estimated impedance values. The model used to provide the estimations is a parallel RLC circuit valid at resonance frequency which will be transferred to the real model considering the mentioned interval of frequencies. A straightforward algorithm is suggested and programmed using MATLAB which does not require a wide knowledge of design parameters and could be implemented using a spectrum analyzer. The inputs are the measured impedance samples as a function of frequency along with the diameter of the conductors. The suggested algorithm practically provides the estimated parameters of a real inductance model at different frequencies, with or without design information. The suggested work is different from designing a high frequency inductor; it is rather concentration of determining the parameters of an available real inductor that could be easily done by a recipe provided to a technician.

A study on development of Power Cable countermeasuring EFT IEC801-4 (EFT IEC801-4 대책용 전원케이블의 개발에 관한 연구)

  • 김형근;배대환;민경찬;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 1995
  • Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( $C_y$ type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.

  • PDF

Realization of CAT Interface supporting Multitask (다중처리를 지원하는 CAT 인터페이스에 관한 연구)

  • 전동근;노승환;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.12
    • /
    • pp.1423-1436
    • /
    • 1992
  • In the paper, a CAT interface supporting multitask is realized. To interface a computer with measuring instruments, a GPIB card is designed and implemented. Controlling and displaying software using OOP and GUI are programmed with C++. A spectrum analyzer and a power meter are chosen as object instrument to be controlled. Total 9 modules are configured to manage the various resources and each module in integrated system. Also in case that several instruments are used, the system is realized to be capable of multitasking to exchange the data mutually. The multitasking is implemented under the time-sharing DOS environment. Thread-based method is used for processing, and Round Robin method for scheduling. Provided proper software modules for other object instruments are integrated, the system can control more measuring instruments simultaneously by the computer. Users can save the time and errors even without expert knowledge.

  • PDF