• Title/Summary/Keyword: Spectrum Analyzer

Search Result 261, Processing Time 0.026 seconds

Determination of Spectrum-Exposure Rate Conversion Factor for a Portable High Purity Germanium Detector (휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자의 결정)

  • Kwak, Sang-Soo;Park, Chong-Mook;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.29-40
    • /
    • 1988
  • A spectrum-exposure rate conversion operator G(E) for a portable HPGe detector used for field environmental radiation survey was theoretically developed on the basis of a space distribution function of gamma flux emitted from a disk source and an areal efficiency of the detector. The radiation exposure rates measured using this G(E) and the portable HPGe. detector connected to a portable multichannel analyzer were compared with those measured by a 3' ${\phi}\;{\times}$3' NaI(Tl) scintillation detector with the reported G(E) and a pressurized ionization chamber. A comparison of the three results showed that the result obtained using the HPGe detector was lower than those determined using the NaI(Tl) detector and ionization chamber by 17% to 29%, The difference obtained is close to that reported in literature. The method developed here can be easily applicable to obtain a G(E) factor suitable to any detector for detecting the exposure rate of environmental gamma radiation, since the spectrum-exposure rate conversion operator can be calculated by a hand calculator.

  • PDF

Synthesis of Silver Nanocrystallites by a New Thermal Decomposition Method and Their Characterization

  • Lee, Don-Keun;Kang, Young-Soo
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.252-256
    • /
    • 2004
  • We formed silver nanocrystallites by the thermal decomposition of a $Ag^{+1}$-oleate complex, which was prepared by a reaction with $AgNO_{3}$ and sodium oleate in a water solution. The resulting monodispersed silver nanocrystallites were produced by controlling the temperature (290$^{\circ}$C). Transmission electron microscopic (TEM) images of the particles showed a 2-dimensional assembly of the particles with a diameter of $9.5{\pm}0.7nm$, demonstrating the uniformity of these nanocrystallites. An energy-dispersive X-ray (EDX) spectrum and X-ray diffraction (XRD) peaks of the nanocrystallites showed the highly crystalline nature of the silver structure. We analyzed the decomposition of the $Ag^{+1}$-oleate complex using a Thermo Gravimetric Analyzer (TGA) and observed the crystallization process using XRD.

  • PDF

Insulation Diagnosis Study of Power XLPE Cable by Used Atenna (안테나를 이용한 전력용 케이블의 절연진단 연구)

  • Lee, H.C.;Choie, U.H.;Park, K.S.;Yoon, D.H.;Jee, S.W.;Lee, S.H.;Kim, C.N.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1805-1807
    • /
    • 2004
  • This simulated partial discharge caused by 22.9[kV] power cable using XLPE(Peroxide Crosslinkable Polyethylene) insulation having the outside damage. Asone of the insulation diagnostic method a radiated electromagnetic waves were measured by an UHF method using a BiconiLog antenna(EMCO-3142) and a spectrum analyzer used to measure EMl, EMC. From results of this study, It was confirmed that discharge progress were possible to be estimated by the proposed method.

  • PDF

A Study on the Design of VCO Used in the Spectrum Analyzer (스펙트럼 분석기용의 전압제어발진기에 관한 연구)

  • Sakong, Sug-Jin;Choe, Han-Gyu;Cha, Gyun-Hyeon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 1985
  • The modulo PLL was applied to the implementation of frequency synthesis with the narrow channel spacing, many channels and three different frequency bands. So , VCO (voltage controlled oscillator) designed In this paper is suitable for the device with three different frequency bands 10Hz, 40Hz, 400Hz channel spacing, and 512 channels.

  • PDF

Automatic Sweep Flattening for Wavelength Sweeping Laser of SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 자동 스위프 평탄화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • In this paper, the automatic sweep flattening for wavelength swept laser of SS-OCT has implemented. Through its performance test applied to the laser, 50 nm flat sweeping range, ${\pm}0.5dB$ fluctuation range, 22 sec the time required, and 10 mW average optical power were obtained. This shows that the realized automatic process can replace the inconvenient manual operation used for polarization control of current sweeping laser. Additionally it cuts costs for optical spectrum analyzer necessary to sweep monitoring.

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

A Study on Conducted EMI Emission Characteristics in 3-Phase PWM Converter (3상 PWM 컨버터의 전도성 EMI 특성에 관한 연구)

  • 채영민;고재석;목형수;최규하;홍순찬;백수현;이은웅
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.41-48
    • /
    • 1997
  • Nowadays, EMI emission characteristics, which causes harmful effect on power distribution system and other equipments, have been studied in field of Power electronics, vigoriously. So, in this paper, the conducted EMI emission is measured and compared for 3-phase diode rectifier and PWM converter according to switching frequency variation and current control method change using LISN(Line Impedance Stabilization Network) and spectrum analyzer.

  • PDF

A Study on Electromagnetic Radiation of Neon Sign by ON/OFF (점멸에 의한 네온사인의 방사전자파 특성에 관한 연구)

  • 김인식;이동인;이광식
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.23-31
    • /
    • 1995
  • As a study on electromagnetic radiation emission from the neon signs, this paper has investigated the characteristics of frequency bands and spectra intensities under the operations of the sign's OFF, ON/OFF and continuous ON states. Also we have studied the above characteristics when a distance between the sign and the antenna is varied. All data were obtained in the range of 0.1∼1,000[MHz] by using spectrum analyzer along with the loop, biconical and log periodic antenna. As the result, we found that the radiated electromagnetic waves of the sign at continuous ON states were measured only in the range of 30∼400[MHz] but those of the sign at ON/OFF states were appeared widely in the range of 2∼1,000[MHz].

  • PDF

Development of Portable Arrhythmia Moniter Using Microcomputer(I) (마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로-)

  • 이명호;안재봉
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

금성통신연구소 - 세계 제일 기업되고자 연구개발

  • 한국발명진흥회
    • 발명특허
    • /
    • v.13 no.1 s.143
    • /
    • pp.36-37
    • /
    • 1988
  • 경기도 안양시 호계동 럭키금성 제1연구단지 내에 위치한 금성통신연구소는 지하1층, 지상 3층(대지 4천 4백 55평, 건평 1천 2백 96평)의 규모로 적극적으로 첨단과학기술의 흡수 및 확산을 목적으로 신설한 연구단과 이러한 신기술을 기업여건에 적합하게 응용하는 개발단을 재편성하여 유선통신단말기를 개발하는 개발 1실, 무선통신단말기를 개발하는 개발 2실, 컴퓨터주변기기를 개발하는 개발 3실, 의료기 및 정보통신기를 개발하는 개발 4실 및 연구개발업무의 효율화를 지원하는 연구관리부 등 현재 2백 20명의 연구원이 연구개발에 매진하고 있다. 또한 CAD실, 전산실, 음향측정실, 키폰 종합실험실, MF실, 기술자료실, 시작실과 Mini Computer, CV Model CAD System, MOS, 음향측정장비, Spectrum Analyzer등 7백여점의 연구기자재를 갖추어 놓고 연구개발업무를 수행하고 있다.

  • PDF