Objectives : The purpose of this study was to investigate inhibitory effects of steamed Polygonatum odoratum extract (POE) on differentiation and adipogenesis in 3T3-L1 adipocytes. Methods : Polygonatum odoratum (P. odoratum) extract was extracted with ethyl acetate. Total phenolic and flavonoid contents in POE were measured for antioxidant activity. The spectrophotometric method was used to determine the DPPH and ABTS radical scavenging activity and ferric-reducing antioxidant potential (FRAP). MTT assay was examined for cell toxicity, oil red O staining was performed for intracelluar adipogenesis in differentiated 3T3-L1 adipocytes. Western blot analysis for measurement of CCAAT/enhancer-binding protein ${\alpha}$ ($C/EBP{\alpha}$), peroxisome proliferator-activated receptor${\gamma}$ ($PPAR{\gamma}$) and AMP-activated protein kinase (AMPK) expressions were performed. Results : The results revealed that POE has antioxidant activities. Contents of total polyphenolics and flavonoids were $50.83{\pm}1.52$ GAE mg/100g dry weight of POE and $17.05{\pm}2.47$ RE mg/100g dry weight of POE, respectively. DPPH radical scavenging activity, and FRAP in 10 mg/ml concentration were $92.1{\pm}0.6%$, $244.8{\pm}9.0{\mu}M$ Fe(II) and ABTS inhibition in 5 mg/ml concentration was $84.8{\pm}4.1%$. Treatment of POE in adipocytes inhibited the differentiation and adipogenesis of 3T3-L1 adipocytes compared to those of vehicle control. Additionally, protein expressions of $C/EBP{\alpha}$ and $PPAR{\gamma}$, major transcription factor for the adipogenic genes, were significantly decreased compared to those of vehicle control (p<0.05). Futhermore, phosphorylation of AMPK was increased in 3T3-L1 adipocytes treated with POE compared to that of vehicle control (p<0.05). Conclusions : we demonstrate that steamed P. odoratum extract (POE) has potentiating antioxidant activities, inhibits differentiation and lipid accumulation and also induces energy expenditure in adipocytes, which may contribute to antiobesity property.
Mineral trioxide aggreagate는 치수 치료제로서 많이 사용되고 있는 재료중 하나이다. 그 중 가장 널리 쓰이고 있는 Proroot white $MTA^{(R)}$는 치아 변색을 일으킨다는 단점이 있다. 이번 연구에서는 MTA 기반 재료들인 Proroot $wMTA^{(R)}$, $Biodentine^{(R)}$, $Endocem^{(R)}$, $RetroMTA^{(R)}$를 치수강에 각각 채워넣어 시간에 따른 치경부의 변색을 비교하고자 하였다. 교정적인 이유로 발치된 75개의 소구치를 사용하여 무작위로 4개의 실험군(n = 60)과 한 개의 대조군(n = 15)으로 나누었다. 치아는 CEJ 하방 2 mm로 수평절단 하였다. 각각의 재료들을 제조사의 지시에 따라 준비한 후 치수강에 채워넣고 입구를 레진을 이용하여 봉인하였다. 치아 색조 측정은 국제조명위원회(Commission International de I'Eclairage, CIE)의 CIE $L^*a^*b^*$ system을 사용하였다. 색조는 분광 광도계를 사용하여 재료를 넣기 전, 재료를 넣고 1일, 1주, 2주, 4주, 8주, 12주, 16주 후로 총 8번 측정하였다. 이원 변량 분산분석(Two way repeated ANOVA)을 사용하여 시간에 따른 CIE $L^*$, $a^*$, $b^*$와 ${\Delta}E$값을 비교 평가하였고 실험군과 대조군과의 통계적 유의성과 상호관계는 본페로니 검정으로 사후 검정하여 p 값이 0.05이하일 때 통계학적으로 유의하다고 간주하였다. Proroot $wMTA^{(R)}$는 시간에 따라 계속적인 $L^*$값의 감소를 보였고, $Endocem^{(R)}$은 재료를 넣은 직 후 육안으로 인지 불가능한 약간의 회색조 변색을 보였으며, $Biodentine^{(R)}$과 $RetroMTA^{(R)}$는 상대적으로 다른 재료보다 색 안정성을 보였다. 결론적으로, 방사선 불투과성 물질로서 산화 비스무스가 포함된 Proroot $wMTA^{(R)}$와 $Endocem^{(R)}$은 치관 변색을 보인 반면, 방사선 불투과성 물질로서 산화 지르코늄이 포함된 $Biodentine^{(R)}$과 $RetroMTA^{(R)}$는 시간에 따른 유의한 색 변화를 보이지 않았다.
흐름 주입 누석법에 의한 알루미늄 이온의 최적 부석 조건을 확립하였다. Eriochrome Cyanine R(ECR) 염료는 pH 6.0에서 알루미늄과 반응하여 535nm에서 최대 흡광도를 갖는 착화합물을 형성한다. 이 반응을 흐름 주입 분석법으로 도입하기 위해 혼합 및 반응 코일이 길이, 아세트산 완충용액의 놀도 및 pH, 온도, 시료 주입 부피를 포함한 반응 조건을 최적화 하였다. 그 결과 혼합 및 반응코일의 길이는 각각 0.5 m와 4 m,아세트산 완충용액의 pH와 농도는 각각 0.6 및 1M,ECR의 농도는 0.56 mM, 반응온도는 40$^{\circ}C$,시료 주입량은 300 ${\mu}L$,최대흡수 파장은 535nm 이었다. 이런한 조건하에서 알루미늄 이론의 검출한계는 0.05mg/L 이하이었고, 반복성은 1%이하로 우수하였다. 시료 측정 주기는 시간당 24회 주입이 가능하였다. 또한 $F^-$, HP$O_4^{2-}$, $Fe^{2+}$, $Fe^{3+}$, $Mn^{2+}$ 이온 및 그타 음이온류의 공존시 방해 현상을 알아본 결과 1,000 mg/L까지는 방해를 일으키지 않았고 $SO_4^{2-}$ 이온은 2,000 mg/L까지도 거의 방해를 일으키지 않았다. 또한 이 방법을 이용하여 전주 및 고창 지역의 상수 및 지하수 중 알루미늄의 농도를 분석한 결과 전주 지역 상수 중에는 평균 0.478 mg/L, 고차지역 상수 중에는 0.278 mg/L로서 전주 지역이 높게 나타났고, 지하수는 전주지역이 0.386 mg/L로서 전주지역이 더 낮게 나타났다.
콜레스테롤의 신속하고 정확한 새로운 분석방법을 모색하기 위하여 본 연구에서는 전기적 전도성이 우수한 MWCNT를 이용하여 전극을 제작하였고, 여러 가지 효소고정화 방법을 통해 전기화학적 감응도 분석을 실시하였다. MWCNT의 전도성을 향상시키기 위해 아민기를 도입한 MWCNT-$NH_2$를 제조하였고, MWCNT-$NH_2$/GCE에 PB를 점착하여 작업전극을 제조하였다. 제조한 작업전극은 0.5~500 ${\mu}M$$H_2O_2$ 농도 범위에서 농도가 증가함에 따라 전류가 비례적으로 증가하였고, 검출한계는 0.1 ${\mu}M$로 나타나 전극이 높은 감도를 가지고 있음을 확인하였다. 또한 콜레스테롤 검출을 위해 적합한 효소 반응기를 제작하기 위해 담체인 aminopropyl glass beads, CNBr-activated sepharose, Na-alginate, toyopearl beads에 cholesterol oxidase를 고정화시켜 바이오센서의 콜레스테롤 표준용액에 대한 감응도를 측정한 결과, aminopropyl glass beads과 CNBr-activated sepharose는 1~100 ${\mu}M$ 범위에서 선형관계를 보였으며, Na-alginate는 5~50 ${\mu}M$의 범위에서, toyopearl beads는 1~50 ${\mu}M$ 범위에서 선형관계를 나타내었다. 검출한계는 제작된 효소반응기 모두 1 ${\mu}M$로 나타나 콜레스테롤에 대한 높은 검출력을 보여주었으나, 특히 CNBr-activated sepharose와 Na-alginate를 이용한 효소반응기가 높은 coupling efficiency와 감응도를 보여 콜레스테롤 검출을 위한 본 바이오 센서 시스템에 적합한 것으로 나타났다.
UV-Vis 분광광도법과 시간분해 레이저 유도 형광분광법(TRLFS)을 이용하여 흄산의 모사 리간드로 사용한 2,6-Dihydroxybenzoate(DHB)와 U(VI)의 착물형성반응을 조사하였다. U(VI)-DHB 착물 고유의 전하이동 흡수 스펙트럼을 분석한 결과, 착물형성반응은 우라늄-리간드 비가 1:1 또는 1:2 착물을 형성하는 이중 평형반응이며, 산도에 따라 착물종의 분포가 변한다는 것을 밝혔다. 계산된 착물형성상수 (log $K_1$ and log $K_2$)는 $12.4{\pm}0.1$과 $11.4{\pm}0.1$이다. 이에 더하여, TRLFS 방법으로 조사한 결과, DHB는 U(VI) 화학종들의 형광 소광제(quencher)로서 역할을 한다는 것을 확인하였다. 특히, 확인된 U(VI) 화학종 모두(${UO_2}^{2+}$, $(UO_2)_2{(OH)_2}^{2+}$과 $(UO_2)_3(OH)_5{^+})$에서 정적 (static) 및 동적 (dynamic) 소광작용이 공존하는 것으로 관찰되었다. 시간분해 형광 스펙트럼으로부터 리간드 농도에 따른 U(VI) 화학종의 형광세기와 형광수명을 측정하였으며, Stern-Volmer 식을 이용하여 분석하였다. 결정된 정적소광계수(KS)는 ${UO_2}^{2+}$, $(UO_2)_2{(OH)_2}^{2+}$ 과 $(UO_2)_3(OH)_5+$에 대하여 각각 $4.2{\pm}0.1$, $4.3{\pm}0.1$ 과 $4.34{\pm}0.08$이다. Stern-Volmer 식을 이용한 분석 결과, 단일 또는 이중 배위자 구조(mono- and bi-dentate)의 U(VI)-DHB 착물이 모두 정적소광효과에 관여하는 바닥상태 착물임을 확인하였다.
다목적실용위성(KOMPSAT-3A: Korea Multi-Purpose Satellite 3A)으로부터 산출된 지표 반사도 성과의 검정 작업을 위하여 분광 반사도 측정값을 제공하고 있는 포털인 Radiometric Calibration Network(RadCalNet)에서 제공하는 4 개의 사이트 자료 중에서 중국 바오터우(Baotou: BTCN) 데이터를 이용한 실험을 수행하였다. 실험을 위한 반사도 성과는 대기 반사도와 지표 반사도를 일괄적으로 처리할 수 있도록 재설계하고 구현한 오픈소스 Orfeo ToolBox(OTB)의 확장 프로그램(Extension)을 이용하여 생성하였다. 절대 대기 보정에 적용되는 두 가지의 센서 모델 변수를 고려하여 2016년, 2017년, 2018년 자료 1개씩 총 3개의 영상 자료를 실험에 적용하였다. 한편 각각 USGS LaSRC 알고리즘과 SNAP Sen2Cor 프로그램을 이용하여 Landsat-8과 Sentinel-2B 영상정보로부터 산출한 반사도 성과와의 비교 검증 작업을 수행하여 센서 별 차이를 확인하고자 하였다. 대기 반사도와 지표 반사도를 대상으로 절대 대기 보정을 위한 필수 입력 값인 Gain과 Offset에 대한 센서 모델 변수 값을 적용한 결과로, 2019년에 발표된 변수 값을 사용한 성과에 비하여 2017년 변수 값을 사용한 성과가 RadCalNet BTCN 자료에 비교적 잘 부합되는 것으로 나타났다. RadCalNet BTCN 자료를 기준으로 KOMPSAT-3A 영상정보의 지표 반사도 성과와의 차이는 밴드 별로 B 밴드(-0.031 ~ 0.034), G 밴드(-0.001 ~ 0.055), R 밴드(-0.072 ~ 0.037), NIR 밴드(-0.060 ~ 0.022)로 일치도가 높은 것으로 나타났고, Landsat-8 영상과 Sentinel-2B 영상의 지표 반사도의 경우도 KOMPSAT-3A 영상의 지표 반사도 성과의 정확도와 유사한 수준인 것으로 나타났다. 이번 연구 결과는 고해상도 위성에서 지표 반사도 값에 대한 분석 대기 데이터(Analysis Ready Data: ARD) 적용 가능성을 확인한 것에 의미가 있다.
연구목적: 인간은 누구나 아름다움을 추구하는 욕망을 가지고 있으며 치의학 분야에서도 심미란 중요한 치료목적 중의 하나이다. 최근에는 부하를 많이 받는 구치부에까지 심미적 요구가 증가됨에 따라 지르코니아를 이용한 코아의 사용이 증가되고 있다. 기본적으로 zirconium oxide의 색상은 흰색-상아색이며, 만약 하부구조물이 이미 인접치의 색조와 조화되어 있다면 색조 부여에 훨씬 유리할 것이며, 원하는 색상을 내기 위하여 필요한 도재층의 두께를 감소시킬 수 있어 더 많은 치질을 보존할 수 있을 것이다. 연구재료 및 방법: 이 연구에서는 현재 임상에서 사용되고 있는 3가지 지르코니아 시스템의 코아 색조 부여 유무와 도재층의 두께가 전부도재관의 색조에 미치는 영향을 알아보기 위하여, 각 시스템의 코아에 색조 부여를 한 실험군과 부여하지 않은 실험군으로 구분하여 코아에 축성한 도재층의 두께에 따른 각각의 색조를 분광측색장치를 이용하여 CIE $L^{*}a^{*}b^{*}$ 색체계를 사용하여 색차를 비교, 분석하였다. 결과: 도재층 0.5 mm 축성시 Lava Frame Zirconia 군과 KaVo Everest Zirconia 군은 코아의 색조 부여 유무에 따라 육안으로 인지 가능한 색조 차이를 보이지 않았으나, Digident CAD/CAM Zirconia 군의 경우 육안으로 인지 가능한 색조차이를 보여 하부 코아의 색조가 충분히 피개되지 못하는 것으로 나타났다. 또한 도재층의 두께를 0.4 mm로 감소시켰을 때 코아 자체에 색조를 부여한 Lava Frame Zirconia 군과 KaVo Everest Zirconia 군의 경우 육안으로 인지 가능한 색조의 차이를 보이지 않았으나, 불투명 도재를 도포한 Digident CAD/CAM Zirconia 군의 경우 육안으로 인지 가능한 색조의 차이를 보였다. 결론: 코아 자체에 색조를 부여할 경우 지르코니아 코아 자체의 색을 피개하기 위해 도포하는 불투명 도재층 축성에 필요한 두께를 감소시킬 수 있어 색조 재현에 더욱 유리하며, 치아의 삭제량을 감소시킬 수 있을 것으로 판단되었다.
Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.
연구배경: 흉수의 원인을 규명하는 방법으로는 임상소견, 흉수 분석, 그리고 흉막생검 등이 있다. 그러나 이와 같은 적극적인 검사에도 불구하고 약 20%의 환자에서 흉수의 원인을 모르는 것으로 알려져 있다. 결핵성 흉막염은 우리나라에서 가장 흔히 보는 흉막질환이지만 흉수에서 결핵균 양성율은 20-30%에 불과하고 흉막생검 양성율도 50%를 넘지 않아 감별진단이 어려운 경우를 임상에서 종종 경험하게 된다. 본 연구에서는 흉수의 감별진단에 있어 흉수에서의 ADA(adenosine deaminase) 및 동종효소의 활성도 측정의 유용성을 평가하고자 하였다. 방 법: 1996년 1월 부터 6월까지 단국대병원 내과에 흉수로 입원한 54명의 환자들의 흉수와 혈청에 대해 ADA 및 동종효소의 활성도를 측정하였다. 흉수의 원인으로는 결핵성 흉수가 25명, 부폐렴성 흉수가 10명, 악성 흉수가 14명, 여출성 흉수가 5명이었으며, 이들 중 소방형 흉수를 보인 경우는 결핵성 흉수가 5명, 부폐렴성 흉수가 6명이었다. 총 ADA 활성도와 동종효소 활성도 측정은 spectrophotometry로 시행하였으며, ADA2 동종효소의 활성도 측정은 ADAl의 강력한 억제제인 EHNA(erythro-9-(2-hydroxy-3-nonyl) adenine)을 이용하여 측정하였다. 결 과: 결핵성 흉수에서의 총ADA 활성도는 악성 흉수보다 높았으나 (p<0.l), 결핵성 흉수와 부폐렴성 흉수사이에는 유의한 차이가 없었다(결핵성 흉수 : $148.9{\pm}89.9IU/L$, 부폐렴성 흉수 : $129.0{\pm}119.4IU/L$, 악성흉수 : $60.7{\pm}17.8%$). 흉수에서 총 ADA에 대한 ADA2 동종효소의 활성도의 비 (ADA2%)는 결핵성 흉수에서 부폐렴성 흉수에 비해 유의하게 놓았으나(p<0.05), 결핵성 흉수와 악성 흉수 사이에는 유의한 차이가 없었다(결핵성 흉수: $57.2{\pm}10.7%$, 부폐렴성 흉수 : $35.9{\pm}17.8%$, 악성 흉수 : $60.7{\pm}17.8%$). 소방형 흉수의 경우 총 ADA 활성도는 결핵성흉수와 부폐렴성 흉수 사이에 유의한 차이가 없었으나(결핵성 흉수 : $157.8{\pm}100.8$ IU/L, 부폐렴성 흉수 : $164.3{\pm}132.3$ IU/L), ADA2% 는 결핵성 흉수에서 부폐렴성 흉수보다 유의하게 높았다(p<0.005)(결핵성 흉수 : $53.3{\pm}3.9%$, 부폐렴성 흉수 : $27.8{\pm}7.9%$). 결 론: 흉수에서 ADA동종효소의 측정은 결핵성 흉수와 부폐렴성 흉수의 감별진단에 유용하며 특히 소방형 흉수의 경우와 같이 임상적으로 강별이 용이치 않은 경우에 더욱 유용할 것으로 생각된다
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.