• 제목/요약/키워드: Spectral range

검색결과 948건 처리시간 0.025초

TGS 초전검출기 제작 및 성능검사 (Fabrication and Performance Test of TGS Pyroelectric Detectors)

  • 김석원
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.230-234
    • /
    • 1989
  • Pyroelectric TGS(triglycine sulfate) detectors, whose thicknesses are 0.1mm and 0.2 mm, are fabricated using the grown TGS crystals from aqueous solution. The outut power and noise from these detectors are measured as a function of chopping frequency in the range from 10Hz to 160Hz with the interval of 10Hz. Response time, responsivity and detectivity are derived from the measured output power and noise of the detectors. The results show that the response time is about 15ms, resposivity is 100V/W at 10Hz and the detectivity at the maximum spectral wavelength D{{{{ lambda }}P* is about 10 cmHz1/2w-1.

  • PDF

분광반사특성을 이용한 벼의 생장량 추정 (Estimation of Paddy Rice Growth Increment by Using Spectral Reflectance Signature)

  • 홍석영;이정택;임상규;정원교;조인상
    • 대한원격탐사학회지
    • /
    • 제14권1호
    • /
    • pp.83-94
    • /
    • 1998
  • 분광반사 특성을 이용한 벼 군락의 생육시 기별 생장량을 추정하기 위하여 분광방사계 (GER Inc. SFOV : 0.35~2.5 $\mu\textrm{m}$)를 이용하여 이앙기부터 수확기가지 매 1주 또는 2주 간격으로 분광반사 특성을 조사하였다. Landsat TM 동등 밴드의 평균반사율을 계산하여 엽면적지수와 건물량과 같은 벼의 중요한 생장량 관련 변수와의 관계를 살펴 보았다. 생육단계에 따른 벼 군락의 질적변화(출수. 개화, 등숙 등)와 건물량이나 엽면적의 증감에 따른 양적변화에 따라 분광반사 광량이 달라지는데 가시광선대(0.4~0.7 $\mu\textrm{m}$)의 경우 청색능.녹색능.적색능에서 모두 출수기까지는 생장량이 많을수록 반사율은 낮아졌으며, 출수 후 이삭이 성숙하면서 반사율은 높아졌는데 특히 적색능의 반사율은 다른 두 가시광선 파장 영역에 비하여 더 높아지는 경향이었다. 근적외선대(0.7~1.1 $\mu\textrm{m}$)의 경우 생장량이 많을수록 반사율은 약 45 %까지 높아졌다가 유수분화기 후 감소하여 등숙기에는 약 20 %로 낮아졌다. 또한 출수 이전의 분광반사 특성과 벼의 생장량 관련 변수와의 상관계수 값이 출수 이후보다 높게 나타났다. 한편, TM 동등 밴드의 평균반사율($\bar{p}$$_{TMi}$) 또는 밴드간 비율값 RV(Ratio Value ; $\bar{p}$$_{TMi}$/$\bar{p}$$_{TMi}$)와 엽면적지수 및 건물량과의 상관관계를 살펴본 바, 엽면적지수와 건물량은 가시광 영역의 $\bar{p}$$_{TMi}$, $\bar{p}$$_{TM1}$, $\bar{p}$$_{TM2}$, $\bar{p}$$_{TM3}$과 밴드간 비율값 중 $\bar{p}$$_{TM4}$/$\bar{p}$$_{TM3}$, $\bar{p}$$_{TM4}$/$\bar{p}$$_{TM2}$, $\bar{p}$$_{TM4}$/$\bar{p}$$_{TM1}$, log($\bar{p}$$_{TM4}$/$\bar{p}$$_{TM3}$) 등과 상관이 높게 나타났다.

아연섭취에 따른 적상추의 분광학적 반응: 중금속 오염토양에서의 반응실험 (Spectral Response of Red Lettuce with Zinc Uptake: Pot Experiment in Heavy Metal Contaminated Soil)

  • 신지혜;유재형;김지은;고상모;이범한
    • 자원환경지질
    • /
    • 제52권2호
    • /
    • pp.129-139
    • /
    • 2019
  • 본 연구는 적상추(Lactuca sativa var crispa L.)가 아연을 축적함에 따라 발생하는 분광학적 반응특성을 고찰하기 위해, 대조군(T0)과 1 mM(ZnT1), 5 mM(ZnT2), 10 mM(ZnT3), 50 mM(ZnT4), 100 mM(ZnT5)로 처리된 실험군을 제작하여 분실험을 실시하였다. 대조군의 아연함량은 134-181 mg/kg의 범위로 오염되지 않은 농작물이 갖는 정상수준의 아연함량을 보였다. 그러나 아연용액의 주입농도가 증가하고 시간이 경과함에 따라 실험군 내 아연함량은 증가하였다. 적상추의 분광반사도는 적색밴드에서 안토시아닌에 의한 높은 피크, 적외선 대역에서 세포구조의 산란효과로 인한 높은 반사도, 그리고 물에 기인한 흡광특성이 관찰되었다. 적상추 내 아연이 고농도로 축적됨에 따라 녹색과 적색밴드에서는 반사도가 증가하고 적외선 대역에서는 반사도가 감소하였다. 아연함량과 분광반사도 사이의 상관관계 분석결과는 700-1300 nm의 파장대역이 아연함량과 유의한 음의 상관관계를 가짐을 보여주었다. 해당 파장대역은 잎 중의 세포구조와 밀접한 관계가 있는 파장대역으로 아연함량이 증가함에 따라 잎 중의 세포구조가 파괴됨을 지시한다. 특히 적외선 대역 중 700-800 nm은 아연함량과 가장 강한 상관관계를 보여주었다. 본 연구는 적상추의 중금속 오염을 분광학적으로 인지하여 광업 및 농업지역 주변 토양 내 중금속 오염을 조사하는데 활용 가능할 것으로 판단된다.

대향 타겟식 스퍼티링법을 이용한 저저항 투명전도 다층박막의 제작 (Preparation of Low Resistivity Transparent Conductive multilayer Thin Films by The Facing Targets Sputtering)

  • 김상모;박용서
    • 반도체디스플레이기술학회지
    • /
    • 제13권2호
    • /
    • pp.13-16
    • /
    • 2014
  • We prepared the ITO/Ag multilayer thin films on soda-lime glass substrate by the Facing Target Sputtering System (FTS) at room temperature. To confirm the effect of Ag layer in ITO/Ag multilayer thin films, we have prepared various range of Ag layer in its thickness and investigated prior to the setting of ITO/Ag multilayer thin films. The thickness of Ag layer was controlled by the sputtering deposition time. Properties of as-prepared samples were investigated by using a four-point probe, UV-Visual spectrometer with a spectral visual range (400 - 800 nm) and X-ray diffractometer (XRD). As a result, the transmittance of as-prepared samples turned out to be very low in the visible range due to light-scattering on the surface of thin film as the thickness of Ag layer got increased. However, reduction of phenomenon of light-reflection in visual range was observed around 20nm of Ag thickness. We prepared the ITO/Ag multilayer thin film with a resistivity of about $8{\times}10^{-5}[{\Omega}-cm]$ and a transmittance of more than 80 % at 550 nm.

SOUND SPECTROGRAPH를 이용한 개교환자의 한국어 자${\cdot}$모음의 발성에 관한 연구 - 주파수 분석을 중심으로 - (A SOUND SPECTROGRAPHICAL STUDY ON THE KOREAN VOWELS AND CONSONANTS PRONOUNCED BY OPENBITE PATIENTS - Frequency Analysis -)

  • 김기달;양원식
    • 대한치과교정학회지
    • /
    • 제15권1호
    • /
    • pp.55-66
    • /
    • 1985
  • The study was undertaken to ascertain the speech defect of patients with malocclusion, especially of openbite patients, by means of the spectral analysis method. The experimental group was composed of ten female openbite patients and their mean age was 13.8 yrs. The control group was also composed of ten female girls and their mean age was 13.7 yrs. As for the speech material, eight Korean monophthrongs and two Korean fricatives and two affricatives were used. Speeches were recorded and then analyzed by a Kay 7800 digital sonagraph. Formant frequency level or range was used as a phonemic parameter. The results were as follows: 1. Among Vowels /a:/ : $F_1,\;F_3\;and\;F_1/F_2$ showed abnormality. /o:/ and $/w:/:F_2,\;F_2-F_1\;and\;F_1/F_2$ showed abnormality. 2. Among Consonants /S/ and /h/ : The upper and lower borders of the frequency range showed abnormality. (equation omitted) : The lower border of the frequency range showed abnormality. $/C^{h}/$ : The upper and lower borders of the frequency range and concentration point showed abnormality.

  • PDF

무인차량 라이다용 CMOS 듀얼채널 자동 이득조절 트랜스임피던스 증폭기 어레이 (A Dual-Channel CMOS Transimpedance Amplifier Array with Automatic Gain Control for Unmanned Vehicle LADARs)

  • 홍채린;박성민
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.831-835
    • /
    • 2016
  • In this paper, a dual-channel feed-forward transimpedance(TIA) array is realized in a standard $0.18-{\mu}m$ CMOS technology which exploits automatic gain control function to provide 40-dB input dynamic range for either detecting targets nearby or sensing imminent danger situations. Compared to the previously reported conventional feed-forward TIA, the proposed automatic-gain-control feed-forward TIA(AFF-TIA) extends the input dynamic range 25 dB wider by employing a 4-level automatic gain control circuit. Measured results demonstrate the linearly varying transimpedance gain of 47 to $72dB{\Omega}$, input dynamic range of 1:100, the bandwidth of $${\geq_-}670MHz$$, the equivalent input referred noise current spectral density of 6.9 pA/${\surd}$HZ, the maximum sensitivity of -26.8 dBm for $10^{-12}BER$, and the power consumption of 27.6 mW from a single 1.8-V supply. The dual-channel chip occupies the area of $1.0{\times}0.73mm^2$ including I/O pads.

인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구 (Development of Radiation Thermometer using InSb Photo-detector)

  • 황병옥;이원식;장경영
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠 (Seismic attenuation from VSP data in methane hydrate-bearing sediments)

  • 송도 윤
    • 지구물리와물리탐사
    • /
    • 제10권1호
    • /
    • pp.29-36
    • /
    • 2007
  • 최근의 탄성파 탐사들은 퇴적층에 메탄 하이드레이트가 존재할 경우 탄성파 진폭 감쇠에 큰 영향을 미치는 것을 보여주고 있다. 이 논문에서는 일본 중부 토카이(Tokai) 해역의 난카이 트러프 (Nankai Trough) 탐사정에서 얻은 수직탄성파자료를 이용하여 30$\sim$110 Hz 주파수 대역에서 메탄 하이드레이트 부존층에서의 P 파 감쇠를 측정하였다. 두 개의 다른 측정방법들 (스펙트럼비 (spectral ratio) 방법과 중심 주파수 이동방법 (centroid frequency shift method))을 이용하여 감쇠 측정의 유효성을 조사하였다. 또한 감쇠 측정의 안정성을 증명하기 위해 측정 심도구간, 시추공의 불규칙 변화, 주파수 구간에 따른 감쇠 분석의 민감도를 조사하였다. 탄성파 주파수 대역에서는 메탄 하이드레이트 부존층에서 P 파의 큰 진폭 감쇠는 발견되지 않았다. 육안으로 보기에는 탄성파 주파수 대역에서의 최대 감쇠는 저포화도의 가스층에 발생한다. 그와는 반대로 같은 시추공에서 얻어진 음파검층의 주파수 대역 $(10{\sim}20\;kHz)$에서는 가장 높은 P 파의 진폭 감쇠가 메탄 하이드레이트 부존층과 관련이 있었다. 그러므로 이 연구는 메탄 하이드레이트 부존 퇴적층의 진폭 감쇠가 주파수에 의존함을 보여주고 있다. 메탄 하이드레이트 부존층은 탄성파 주파수 대역보다는 음파검층 주파수 대역에서 진폭 감쇠를 유발함을 알 수 있다. $30{\sim}110\;Hz$의 탄성파 주파수 대역이 메탄 하이드레이트 부존에 영향을 받지 않는 이유 중의 하나로서 메탄 하이드레이트 지역의 얇은층 들로 이루어진 층서구조의 영향을 제시하였다.

Identification of MgII Absorbers in the Quasar Lines of Sight

  • Shim, Hyunjin
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.75.3-75.3
    • /
    • 2015
  • Large area infrared surveys are often accompanied with follow-up optical spectroscopic surveys that has a significant legacy value even for other areas of research. Using these spectral database, we have performed a search for MgII absorption lines in the optical spectrum of background quasar. Over the ~4deg2 of AKARI North Ecliptic Pole survey field and Spitzer First Look Survey field, 18 and 16 MgII absorber systems are identified respectively. The redshift range for the background quasars was 1.0<$z_{qso}$<3.4, while the redshift range for the absorber was 0.6<$z_{abs}$<1.6. Galaxies responsible for MgII absorptions are identified in the deep optical images (CFHT r-band), yet the identification still remains ambiguous for 60% of the systems due to the limited image depth and the source crowdedness. The impact parameter ranges 20-60kpc, and the rest-frame equivalent width of MgII absorption ranges $0.7-4{\AA}$. The most critical part in the identification of MgII absorber galaxies is the existence of deep optical images in addition to the high S/N quasar spectrum with R>3000.

  • PDF

Dielectric and Transport Properties of Acetonitrile at Varying Temperatures: a Molecular Dynamics Study

  • Orhan, Mehmet
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권5호
    • /
    • pp.1469-1478
    • /
    • 2014
  • Use of acetonitrile in electrolytes promotes better operation of supercapacitors. Recent efforts show that electrolytes containing acetonitrile can also function in a wide range of operating temperatures. Therefore, this paper addresses the dielectric relaxation processes, structure and dynamic properties of the bulk acetonitrile at various temperatures. Systems of acetonitrile were modeled using canonical ensemble and simulated by employing Molecular Dynamics method. Results show that interactions among the molecules were correlated within a cut-off radius while parallel and anti-parallel arrangements are observed beyond this radius at relatively high and low temperatures respectively. Furthermore, effects of C-C-N and C-H bending modes were greatly appreciated on the power spectral density of time rate change of dipole-dipole correlations whereas frequency shifts were observed on all modes at the lowest temperature under consideration. Linear variations with temperature were depicted for reorientation times and self-diffusion coefficients. Shear viscosity was also computed with a good accuracy within a certain range of the temperature as well.