• Title/Summary/Keyword: Spectral range

Search Result 949, Processing Time 0.022 seconds

Landsat TM Image Compression Using Classified Bidirectional Prediction and KLT (영역별 양방향 예측과 KLT를 이용한 인공위성 화상데이터 압축)

  • Kim Seung-Jin;Kim Tae-Su;Park Kyung-Nam;Kim Young-Choon;Lee Kuhn-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • We propose an effective Landsat TM image compression method using the classified bidirectional prediction (CBP), the classified KLT and the SPIHT. The SPIHT is used to exploit the spatial redundancy of feature bands selected in the visible range and the infrared range separately. Regions of the prediction bands are classified into three classes in the wavelet domain, and then the CBP is performed to exploit the spectral redundancy. Residual bands that consist of difference values between the original band and the predicted band are decorrelated by the spectral KLT Finally, the three dimensional (3-D) SPIHT is used to encode the decorrelated coefficients. Experiment results show that the proposed method reconstructs higher quality Landsat TM image than conventional methods at the same bit rate.

초석잠(Stachys sieboldii MIQ.) 줄기와 뿌리 추출물의 특성분석과 아질산염 소거능에 대한 고찰

  • Song, Seung-Gu;Baek, Hong-Seok;Jang, Ji-Yeong;Ryu, Byeong-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.489-493
    • /
    • 2003
  • This study was to search antioxidant constituents of ethyl acetate extract from Stachys siebodlii MIQ. The test of nitrite scavenging abilities were performed on the extracts of methanol, hexane, chloroform, ethyl acetate, butanol, and water, Ethyl acetate extract, The most promising one was fractionated on a silical gel column using elution solvent(chloroform:methanol:water=70:30:5 lower phase) at a flow rate 1.0ml/min. UV-VIS spectral data of each fraction showed adsorption maxima in the range of $284{\sim}330nm$ which is the characteristic range of $210{\sim}290nm$ and $300{\sim}550nm$ phenolic compounds. These results suggested that Stachys siebodlii MIQ. shows natural antioxidant activity. The nitrite scavenging abilities reached the maxium at pH 1.2 and the ethyl acetate fraction of root showed stronger scavenging ability.

  • PDF

MEAT SPECIATION USING A HIERARCHICAL APPROACH AND LOGISTIC REGRESSION

  • Arnalds, Thosteinn;Fearn, Tom;Downey, Gerard
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1245-1245
    • /
    • 2001
  • Food adulteration is a serious consumer fraud and a matter of concern to food processors and regulatory agencies. A range of analytical methods have been investigated to facilitate the detection of adulterated or mis-labelled foods & food ingredients but most of these require sophisticated equipment, highly-qualified staff and are time-consuming. Regulatory authorities and the food industry require a screening technique which will facilitate fast and relatively inexpensive monitoring of food products with a high level of accuracy. Near infrared spectroscopy has been investigated for its potential in a number of authenticity issues including meat speciation (McElhinney, Downey & Fearn (1999) JNIRS, 7(3), 145-154; Downey, McElhinney & Fearn (2000). Appl. Spectrosc. 54(6), 894-899). This report describes further analysis of these spectral sets using a hierarchical approach and binary decisions solved using logistic regression. The sample set comprised 230 homogenized meat samples i. e. chicken (55), turkey (54), pork (55), beef (32) and lamb (34) purchased locally as whole cuts of meat over a 10-12 week period. NIR reflectance spectra were recorded over the wavelength range 400-2498nm at 2nm intervals on a NIR Systems 6500 scanning monochromator. The problem was defined as a series of binary decisions i. e. is the meat red or white\ulcorner is the red meat beef or lamb\ulcorner, is the white meat pork or poultry\ulcorner etc. Each of these decisions was made using an individual binary logistic model based on scores derived from principal component or partial least squares (PLS1 and PLS2) analysis. The results obtained were equal to or better than previous reports using factorial discriminant analysis, K-nearest neighbours and PLS2 regression. This new approach using a combination of exploratory and logistic analyses also appears to have advantages of transparency and the use of inherent structure in the spectral data. Additionally, it allows for the use of different data transforms and multivariate regression techniques at each decision step.

  • PDF

MEAT SPECIATION USING A HIERARCHICAL APPROACH AND LOGISTIC REGRESSION

  • Arnalds, Thosteinn;Fearn, Tom;Downey, Gerard
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1152-1152
    • /
    • 2001
  • Food adulteration is a serious consumer fraud and a matter of concern to food processors and regulatory agencies. A range of analytical methods have been investigated to facilitate the detection of adulterated or mis-labelled foods & food ingredients but most of these require sophisticated equipment, highly-qualified staff and are time-consuming. Regulatory authorities and the food industry require a screening technique which will facilitate fast and relatively inexpensive monitoring of food products with a high level of accuracy. Near infrared spectroscopy has been investigated for its potential in a number of authenticity issues including meat speciation (McElhinney, Downey & Fearn (1999) JNIRS, 7(3), 145 154; Downey, McElhinney & Fearn (2000). Appl. Spectrosc. 54(6), 894-899). This report describes further analysis of these spectral sets using a hierarchical approach and binary decisions solved using logistic regression. The sample set comprised 230 homogenized meat samples i. e. chicken (55), turkey (54), pork (55), beef (32) and lamb (34) purchased locally as whole cuts of meat over a 10-12 week period. NIR reflectance spectra were recorded over the wavelength range 400-2498nm at 2nm intervals on a NIR Systems 6500 scanning monochromator. The problem was defined as a series of binary decisions i. e. is the meat red or white\ulcorner is the red meat beef or lamb\ulcorner, is the white meat pork or poultry\ulcorner etc. Each of these decisions was made using an individual binary logistic model based on scores derived from principal component or partial least squares (PLS1 and PLS2) analysis. The results obtained were equal to or better than previous reports using factorial discriminant analysis, K-nearest neighbours and PLS2 regression. This new approach using a combination of exploratory and logistic analyses also appears to have advantages of transparency and the use of inherent structure in the spectral data. Additionally, it allows for the use of different data transforms and multivariate regression techniques at each decision step.

  • PDF

Synergism Between Zinc and Taurine in the Visual Sensitivity of the Bullfrog's Eye

  • Kim, Hyun-Jung;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.7 no.3
    • /
    • pp.115-121
    • /
    • 2000
  • Although there are high concentrations of zinc and taurine in ocular tissue, their exact role and correlation in the visual process are not clear. The purpose of present study was to clarity this point using electroretinogram (ERG) recording and spectrophotometer measurements before and after zinc and taurine treatment in bullfrog's eye. The optimal zinc concentration used in this study was 10$^{-2}$ M ZnCl$_2$120 ${mu}ell$/12$m\ell$ ringer solution while the optimal turine concentration was 10$^{-2}$ M taurine 12${mu}ell$/12$m\ell$ ringer solution. For the effects of zinc and taurine on the retinal function, the changes of ERG parameters (especially threshold and b-wave) and absorption spectra were observed before and after treatment. It is noteworthy that high concentrations of zinc and taurine present in the retinal pigment epithelium and the retina. Our results indicate that dark-adapted ERG threshold became elevated and the peak amplitude of b-wave was increased with zinc and taurine treatment. Furthermore there are some synergism effects between zinc and taurine as a result of co-treatment. In spectral scan, absorbance increment due to zinc and taurine treatment was shown over the whole range of spectral range (300-750 nm) with some differences in absorbance increment depending on the case of treatment. As the results of above we believe that zinc and taurine, which are abundant in the retinal pigment epithelium and the retina particularly, may be essential factors for visual process, have some synergism with each other and be required to improve the visual sensitivity during visual adaptation.

  • PDF

OPTICAL DESIGN OF THE FAR ULTRAVIOLET IMAGING SPECTROGRAPH (원자외선 영상/분광 측정기 광학설계)

  • ;;;Jerry Edelstein
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.359-371
    • /
    • 1998
  • We present the design specifications and the performance estimation of the FUVS (Far Ultraviolet Spectrograph) proposed for the observations of aurora, day/night airglow and astronomical objects on small satelltes in the spectral range of $900~1750AA$. The design of FUVS is carried out with the full consideration of optical characteristics of the grating and the aspheric substrate. Two independent methods, ray-tracing and the wave front aberration theory, are employed to estimate the performance of the optical design and it is verified that both procedures yield the resolution of $2~5AA$ in the entire spectral range. MDF (Minimum Detectable Flux) is also estimated using the known characteristics of the reflecting material and MCP, to study the feasibility of detection for faint emission lines from the hot interstellar plasmas. The results give that the observations from 1 day to 1 week, depending on the line intensity, can detect such faint emission lines from diffuse interstellar plasmas.

  • PDF

Photonic Microwave Notch Filter with Negative Coefficient Using Reflective Semiconductor Optical Amplifier (반사형 반도체 광 증폭기를 이용한 음계수를 가지는 광 마이크로파 노치 필터)

  • Kwon, Won-Bae;Choi, Yong-Kyu;Kim, Junsu;Kim, Kyung-Ho;Jeong, Min-A;Lee, Seong Ro;Park, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.5
    • /
    • pp.418-424
    • /
    • 2014
  • We propose and experimentally demonstrate a photonic microwave notch filter with a negative coefficient. The negative coefficient is obtained by using cross gain modulation (XGM) in a reflective semiconductor optical amplifier (RSOA). When the RSOA is operated in saturated region, the signal carried on the pump wavelength is inversely copied to the probe wavelength by the XGM effect, showing a negative coefficient. Time delay between pump signal and probe signal is provided by single mode fiber (SMF) with wavelength dependent time delay. The proposed microwave notch filter shows notch dips of more than 35.1 dB and free spectral range (FSR) of about 380.6 MHz.

Ultrahigh-Resolution Spectral Domain Optical Coherence Tomography Based on a Linear-Wavenumber Spectrometer

  • Lee, Sang-Won;Kang, Heesung;Park, Joo Hyun;Lee, Tae Geol;Lee, Eun Seong;Lee, Jae Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • In this study we demonstrate ultrahigh-resolution spectral domain optical coherence tomography (UHR SD-OCT) with a linear-wavenumber (k) spectrometer, to accelerate signal processing and to display two-dimensional (2-D) images in real time. First, we performed a numerical simulation to find the optimal parameters for the linear-k spectrometer to achieve ultrahigh axial resolution, such as the number of grooves in a grating, the material for a dispersive prism, and the rotational angle between the grating and the dispersive prism. We found that a grating with 1200 grooves and an F2 equilateral prism at a rotational angle of $26.07^{\circ}$, in combination with a lens of focal length 85.1 mm, are suitable for UHR SD-OCT with the imaging depth range (limited by spectrometer resolution) set at 2.0 mm. As guided by the simulation results, we constructed the linear-k spectrometer needed to implement a UHR SD-OCT. The actual imaging depth range was measured to be approximately 2.1 mm, and axial resolution of $3.8{\mu}m$ in air was achieved, corresponding to $2.8{\mu}m$ in tissue (n = 1.35). The sensitivity was -91 dB with -10 dB roll-off at 1.5 mm depth. We demonstrated a 128.2 fps acquisition rate for OCT images with 800 lines/frame, by taking advantage of NVIDIA's compute unified device architecture (CUDA) technology, which allowed for real-time signal processing compatible with the speed of the spectrometer's data acquisition.

Empirical ground motion model for Vrancea intermediate-depth seismic source

  • Vacareanu, Radu;Demetriu, Sorin;Lungu, Dan;Pavel, Florin;Arion, Cristian;Iancovici, Mihail;Aldea, Alexandru;Neagu, Cristian
    • Earthquakes and Structures
    • /
    • v.6 no.2
    • /
    • pp.141-161
    • /
    • 2014
  • This article presents a new generation of empirical ground motion models for the prediction of response spectral accelerations in soil conditions, specifically developed for the Vrancea intermediate-depth seismic source. The strong ground motion database from which the ground motion prediction model is derived consists of over 800 horizontal components of acceleration recorded from nine Vrancea intermediate-depth seismic events as well as from other seventeen intermediate-depth earthquakes produced in other seismically active regions in the world. Among the main features of the new ground motion model are the prediction of spectral ordinates values (besides the prediction of the peak ground acceleration), the extension of the magnitudes range applicability, the use of consistent metrics (epicentral distance) for this type of seismic source, the extension of the distance range applicability to 300 km, the partition of total standard deviation in intra- and inter-event standard deviations and the use of a national strong ground motion database more than two times larger than in the previous studies. The results suggest that this model is an improvement of the previous generation of ground motion prediction models and can be properly employed in the analysis of the seismic hazard of Romania.

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.