• Title/Summary/Keyword: Spectral broadening

Search Result 26, Processing Time 0.019 seconds

The Solvent Effect on the Chemical Changes in Binary Mixture : i.e. THF-H2O System (Ⅰ) (이성분 혼합용매에서 화학변화에 미치는 용매의 영향 : THF-$H_2O$ (제1보). 용매화된 전자의 흡수스펙트럼)

  • Yu-Chul Park;Sang Oh;P. Krebs;U. Schindewolf
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.371-379
    • /
    • 1980
  • The spectral properties of the solvated electrons in tetrahydrofuran(THF)-water binary system have been investigated. In this study, the solvated electrons have been produced by applying nsec Q-switch Nd(YAG) laser photolysis technique. The experimental method photolysis were schematically described. The solvent and the temperature effects on the absorption spectrum of solvated electrons have also been studied. The observation of the spectrum with increasing THF content and temperatue showed a trend that the former shifted to longer wavelength and the other showed broadening effect. The half-life of solvated electrons were also increased with THF content. The absorption maxima of the mixtures were always observed in the middle of that of pure water and THF. The correlation between the volume and the absorption energy of solvated electrons were discussed from the results.

  • PDF

Implementation of the Wavelength-Swept-Source and Signal Processing for the Frequency Domain Optical Coherence Tomography (주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원 및 신호처리계의 구현)

  • Lee, Eung-Je;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.309-316
    • /
    • 2007
  • We demonstrate the wavelength swept source and signal processing for the frequency domain optical coherence tomography. The laser output performance is improved by using a semiconductor optical amplifier with a booster amplifier. The laser generates 14 mW of average power of which wavelength shift in the lasing spectral shape is compensated. Adopting a Fabry-Perot etalon and digital signal processing, the broadening of the beat frequency due to the variance of wavelength-sweep-velocity is calibrated. The optical coherence tomography system shows 154.4 kHz of axial scanning speed, 0.95mm of depth range, and $12{\pm}0.37{\mu}m$ of axial resolution.

Color Doppler Ultrasonogram for the Peripheral Vascular disease in Diabetes Patients (당뇨병 환자의 하지 혈관 질환 검사에서 색도플러 초음파의 이용)

  • Lee, Kyung-Tai;Choi, Yun-Sun;Young, Ki-Won;Bae, Sang-Won;Lee, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.80-85
    • /
    • 2002
  • Purpose: This study is to assess the involvement of vessels in lower extremity in diabetics, using color doppler ultrasonogram. Materials and Methods: Arteries of both lower extremities were divided into 3 groups-large vessel (above-knee arteries), popliteal vessel, and small vessel(below-knee arteries) -, and evaluated using color doppler ultrasonogram in 60 diabetics. In color doppler ultrasonogram, the wave forms of all vessels were divided into 5 grades; grade I was triphasic wave form, grade II was spectral broadening form, grade III was monophasic wave form, grade IV was pulsus tardus et parvus form, grade V was absence of wave. Grade III, IV, V were grouped into vessel obstruction. We reviewed the correlationships among the degree of the peripheral vascular involvement, duration of dibetes, existence of bilaterality, types of dibetes. Results: Bilateral involvement was high in both lower extremity. Luminal stenosis, vascular calcification and vessel obstruction were high incidence in the patients over ten years of diabetic duration. Prevalence of vascular calcification and vessel obstruction were high in the small vessel of ankle level. But, insulin injection was not related to the incidence of vascular abnormality. Conclusion: Color doppler ultrasonogram seems to be useful for evaluation of peripheral vascular status, decision making for necessity of additional test, periodic follow -up tool in diabetes patients.

  • PDF

A Study on Dye Variation Extracted from Dyed Textile with Gardenia degraded at HIgh temperature after X-ray Irradiation (X-선 조사 후 고온 열화된 치자 염직물에서 추출한 색소 변이 연구)

  • Da Young Youn;Hae Jin Park;Se Eun Park;Seon Hong Heo;Su Bin Lim;Yong Jae Chung
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.53-61
    • /
    • 2024
  • This study explores the effects of X-ray irradiation for biological control and high-temperature degradation on dye stability in dyed textiles with Gardenia. To evaluate this study, optimal extraction solvents for these textiles were identified by comparing them with a crocin standard solution. Extraction using pyridine closely matched crocin. The study then assessed the stability of X-ray irradiation and high-temperature degradation on these textiles. Transparent yellow dyes were observed in all samples. Color differences were found to increase at higher irradiation doses and longer degradation periods. While UV spectroscopy spectra showed broadening and lowering trends with higher irradiation doses and longer degradation periods, suggesting a reduction in colorant transition, mass spectrometry revealed minimal chemical changes. In conclusion, both X-ray irradiation and high-temperature degradation induced spectral changes without complete dye decomposition. Major colorants were consistently detected.

Optical Properties of Oxotitanium (Ⅳ) Meso-tetrakis(4-sulfonatophenyl)porphyrin Intercalated into the Layered Double Hydroxides (LDH) Studied by Laser Spectroscopy

  • Ryu, Su-Young;Yoon, Min-Joong;Choy, Jin-Ho;Hwang, Sung-Ho;Frube, Akihiro;Asahi, Tsuyoshi;Hiroshi, Masuhara
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.4
    • /
    • pp.446-452
    • /
    • 2003
  • Some new nanohybrid materials have been synthesized by intercalating the oxotitanium(IV) meso-tetrakis(4- sulfonatophenyl) porphyrin$(O=Ti^{(IV)} TSPP)$ into the Zn/Al layered double hydroxides (LDHs), and their structures and photophysical properties have been investigated by various laser spectroscopic techniques. According to the XRD pattern of the synthesized nanohybrid materials, the macrocycle plane of $O=Ti^{(IV)}$ TSPP are grafted perpendicular to the LDH layers. The $O=Ti^{(IV)}$ TSPP-intercalated LDH exhibits band broadening of the absorption spectrum and a blue shift of Q-band as compared to that observed in solution. Resonance Raman spectral measurements demonstrate that the positively charged LDHs give rise to a slight decrease of the electronic density of the porphyrin ring accompanying a small change of the electronic distribution of the $O=Ti^{(IV)}$ TSPP. Consequently the LDH environment affects the energies of the two highest occupied molecular orbitals (HOMOs) of the $O=Ti^{(IV)}$) TSPP, $a_{1u}$ and $a_{2u}$, producing a mixed orbital character. Being consistent with these electronic structural changes of $O=Ti^{(IV)}$ TSPP in LDH, both the fluorescence spectral change and the fsdiffuse reflectance transient measurements imply that the photoexcitation of the $O=Ti^{(IV)}$ TSPP intercalated into LDH undergoes fast relaxation to the O=Ti(IV) $TSPP^+-LDH^- $charge transfer (CT) state within a few picoseconds, followed by a photoinduced electron transfer between the O=Ti(IV) TSPP and LDHs with a rate constant greater than %1×10^{10}S^{-1}$. No evidence is found for back electron transfer. In conclusion, the $O=Ti^{(IV)}$ TSPP intercalated LDH seems to be a possible candidate for an artificial reaction center for an efficient solar energy conversion system.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.