• Title/Summary/Keyword: Spectral Characteristic

Search Result 290, Processing Time 0.655 seconds

Analysis of RP Power Amplifier Nonlinearity and BER Characteristics for Multi­Carrier Transmission System (다중반송 전송시스템을 위한 RF 전력증폭기의 비선형 특성과 BER관계 분석)

  • 신동환;이영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1612-1620
    • /
    • 2003
  • This papers describes a nonlinear transfer function modelling of designed GaAs FET power amplifier by measured and simulated values of designed PA amplifier for multi­carrier transmission system, With the results of PA nonlinearity characteristic, we can estimates AM­AM and AM­PM of designed PA. According to the estimated nonlinear characteristics, we can analysis the ACPR of PA for spectral regrowth, the error vector measurement(EVM) of constallation signals and bit error rate of QPSK and 64­QAM. The suggested nonlinear modelling results are used to get an accurate estimate of digital characteristics between PA amplifier and wireless multi­carrier transmission system using OFDM.

Photoluminescence Study on O-plasma Treated ZnO Thin Films

  • Cho, Jaewon;Choi, Jinsung;Yu, SeGi;Rhee, Seuk Joo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.543-547
    • /
    • 2013
  • A temperature dependent (10K-290K) photoluminescence (PL) study for two differently prepared ZnO thin films (as-grown and O-plasma treated) is presented. Four characteristic peaks were identified for both samples: (i) neutral donor-bound excitons ($D^oX$), (ii) two electron satellites (TES), (iii) phonon replica of $D^oX$ ($D^oX$-1LO), and (iv) donor-acceptor pair transition (DAP). As the sample temperature increased, $D^oX$-1LO and DAP transitions became indistinct. This was accompanied by newly-rising emission of free electron-acceptor transitions (e, $A^o$). The spectral evolution with temperature for as-grown samples also showed the optical emission from free excitons, which became dominant at higher temperatures. Some features related to O-plasma were identified in PL spectra: (i) different positions of TES transitions (28meV lower than $D^oX$ for as-grown samples and 35meV for O-plasma treated samples), (ii) the decrease of spectral intensity in both emissions of $D^oX$ and DAP after O-plasma treatment, and (iii) no noticeable transition from free excitons after the O-plasma treatment.

Evolution of Visual Pigments and Related Molecules

  • Hisatomi, Osamu;Yamamoto, Shintaro;Kobayashi, Yuko;Honkawa, Hanayo;Takahashi, Yusuke;Tokunaga, Fumio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.41-43
    • /
    • 2002
  • In photoreceptor cells, light activates visual pigments consisting of a chromophore (retinal) and a protein moiety (opsin). Activated visual pigments trigger an enzymatic cascade, called phototransduction cascade, in which more than ten phototransduction proteins are participating. Two types of vertebrate photoreceptor cells, rods and cones, play roles in twilight and daylight vision, respectively. Cones are further classified into several subtypes based on their morphology and spectral sensitivity. Though the diversities of vertebrate photoreceptor cells are crucial for color discrimination and detection of light over a wider range of intensities, the molecular mechanism to characterize the photoreceptor types remains unclear. We investigated the amino acid sequences of about 50 vertebrate opsins, and found that these sequences can be classified into five fundamental subfamilies. Clear relationships were found between these subfamilies and their characteristic spectral sensitivities. In addition to opsins, we studied other phototransduction proteins. The amino acid sequences of phototransduction proteins can be classified into a few subfamilies. Even though their spectral sensitivity is considerably different, cones fundamentally share the phototransduction protein isoforms which are different from those found in rods. It is suggested that the difference in phototransduction proteins between rods and cones is responsible for their sensitivity to light. Isoforms and their selective expression may characterize individual photoreceptor cells, thus providing us with physiological functions such as color vision and daylight/twilight visions.

  • PDF

Impedance Analysis of DGS Slot in Spectral Domain and Its Application of LPF(Low Pass Filter) (스펙트럴 영역에서 DGS 슬롯 임피던스 특성 해석 및 LPF 응용)

  • Rhee, Seung-Yeop;Kim, On;Chang, Jae-Soo;Go, Jin-Hyun;Ha, Jae-Kwon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.4
    • /
    • pp.418-426
    • /
    • 2008
  • In this paper, investigations on the impedance characteristics of a DGS(Defected Ground Structure) slot in the groud plane of microstripline are presented in spectral domain and applied to the characteristic improvement of stepped impedance microstrip low pass filter(LPF). In this method, expressions for the impedance of a DGS slot are derived from self-reaction of the angular spectrum of plane waves and the discontinuity in the modal voltage. The numerical results are compared with those of the rigorous full-wave method and are shown to produce reasonably accurate data. And the stepped impedance microstrip low pass filter is designed and fabricated with the uniform and nonuniform DGS slots for improving the frequency responses. The experiments show that the proposed filter with slots in the ground plane has a wider stopband and sharper cutoff response.

Spanwise coherent structure of wind turbulence and induced pressure on rectangular cylinders

  • Le, Thai-Hoa;Matsumoto, Masaru;Shirato, Hiromichi
    • Wind and Structures
    • /
    • v.12 no.5
    • /
    • pp.441-455
    • /
    • 2009
  • Studying the spatial distribution in coherent fields such as turbulence and turbulence-induced force is important to model and evaluate turbulence-induced forces and response of structures in the turbulent flows. Turbulence field-based coherence function is commonly used for the spatial distribution characteristic of the turbulence-induced forces in the frequency domain so far. This paper will focus to study spectral coherent structure of the turbulence and induced forces in not only the frequency domain using conventional Fourier transform-based coherence, but also temporo-spectral coherence one in the time-frequency plane thanks to wavelet transform-based coherence for better understanding of the turbulence and force coherences and their spatial distributions. Effects of spanwise separations, bluff body flow, flow conditions and Karman vortex on coherent structures of the turbulence and induced pressure, comparison between turbulence and pressure coherences as well as intermittency of the coherent structure in the time-frequency plane will be investigated here. Some new findings are that not only the force coherence is higher than the turbulence coherence, the coherences of turbulence and forces depend on the spanwise separation as previous studies, but also the coherent structures of turbulence and forces relate to the ongoing turbulence flow and bluff body flow, moreover, intermittency in the time domain and low spectral band is considered as the nature of the coherent structure. Simultaneous measurements of the surface pressure and turbulence have been carried out on some typical rectangular cylinders with slenderness ratios B/D=1 (without and with splitter plate) and B/D=5 under the artificial turbulent flows in the wind tunnel.

Comparison of Heart Rate Variability with Pulse Transit Time during General Anesthesia (전신 마취 중 심박동변이도와 맥파전달시간 변화의 비교)

  • Baik, Seong-Wan;Kim, Tae-Kyun;Kim, Jae-Hyung;Jeon, Gye-Rok;Ye, Soo-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.770-775
    • /
    • 2008
  • Autonomic nervous system of the anesthetized patients can be influenced by the many kinds of stimulations such as intubation, surgical incision and so on. The changes of the heart rates and blood pressures are surrogates of responses of the autonomic system to the external stimulations. Recently, the power spectral analysis of the heart rate variability (HRV) made it easy to know the fractions and changes of sympathetic and parasympathetic autonomic systems. In this study, the changes of pulse transit time, one of the response of vessels to stimulations, was investigated in relation to the HRV. Ten patients were examined and average age is 22.5 $\pm$ 11.04, average weight is 63 $\pm$ 14.4 kg. The patients were anesthetized only by sevoflurane inhalation. Pulse transit time is determined by calculating the difference of the time between the R peak of ECG and the characteristic point of the plethysmography. Power spectral density (PSD) of the HRV was achieved in the frequency of 0.04-0.15 (LF) and 0.15-0.4 (HF). Compared to preanesthetic period the values of LF and LF/HF ratio of HRV were decreased (p<0.05). HF and PTT was increased in anesthetic state with sevoflurane. Otherwise, after intubation, the HF was decreased and LF, LF/HF ratio and PTT were increased. PSD of the HRV is well-known for the index of the autonomic nervous activity. Not only HRV but PTT analysis also is a useful index reflecting the autonomic responses to various stimulations. And this analysis is useful in bed side monitoring because the calculating method is simple and it takes shorter processing time compared to the HRV analysis.

Ray Tracing Method Based on Spectral Distribution for Reproducing a Realistic Image (실사영상 재현을 위한 분광분포 기반의 광선추적기법)

  • Lee Myong-Young;Lee Cheol-Hee;Lee Ho-Keun;Ha Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.1
    • /
    • pp.37-46
    • /
    • 2004
  • In this paper, we propose an improved reproduction algorithm for a realistic image of the real scene based on the spectral distribution of lights and objects. The proposed method for the realistic image is focused on a more accurate reproduction of an image incident on the sight of the viewer. At first, to reproduce an image accurately incident on a sight of viewer, we used the backward ray tracing method based on spectral distribution of object and illuminant representing its physical characteristic used in real. Next, we propose utilizing the improved shading model of the reproduction algorithm of realistic image by applying Bouguer-Beer's law to consider an optical absorptive property of transparent objects. We also define a new ambient light term which is considered the diffuse reflection of neighboring objects instead of constant ambient light. The simulation results show that the proposed algorithm can reproduce the visually similar image with a scene incident on a sight of viewer.

Effect of Zirconia Core Thickness on the Tone Blocking of Discolored Tooth and Metal Post (지르코니아 코어의 두께에 따른 변색치와 메탈 포스트의 색조차단 효과)

  • O, Seon-Mi;Lee, Chae-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.327-335
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the correlation between zirconia core thickness and color tone blocking of discolored tooth and metal post. Methods: For this study, we made 20-porcelain sample and 4-metal sample( liechtenstein IPS e.max) bonded to zirconia core of different thickness with cement(Relyx ARC-3M USA)for produce discolored. We measured the color-spectral characteristics, using Shadepilot equipment(Degudent USA).We measured it with Shadepilot equipment set by automated average mode in 3 times And applied the average value obtained from 2 times of measurement in the middle of each sample. Results: As a result of analysing color-spectral characteristics on zirconia core sample, Depending on the thickness of zirconia core, the value of brightness(${\Delta}L*$:color-spectral characteristic) was increased within limited range, value of ${\Delta}a*$, ${\Delta}b*$ was decrease. Conclusion: Consequently, we obtained the following results: Changes of sample color were observed depending on the thickness of zirconia, but the range of change did not exceed the scope range of shade guide. The case of metal posts, shade guide color D2 were observed in 0.5mm of zirconia core thickness. As a result, in case of porcelain, increasing the zirconia thickness of 0.3mm or more is unnecessary for color blocking effect, in case of metal post, considering the discolored tooth, thickness of zirconia with at least 0.5mm or more is recommended.

An Approach to the Theoretical Design Standard and Effective Practice of Museum Showcase Lighting (진열장 조명의 이론적 기준과 시설에 대한 고찰)

  • Kim, Hong-Bum
    • 보존과학연구
    • /
    • s.17
    • /
    • pp.123-160
    • /
    • 1996
  • There have been many studies and experiments regarding exhibition lighting. Many experiments on photochemical damaging effect and visibility resulted in a practice limited to assigning light levels and adjusting annual exposure time. The three damaging factors to the artifacts are intrinsicsusceptibility to absorb radiant energy, spectral distribution of light source and intensity of illumination and time of exposure. Dividing all the artfacts into three categories to suggest a recommended illuminance level causes some problems. Blue wool, for example, used as the reference material for susceptibility, is not a standard material representing museum artifacts. In the most light sensitive category, ISO class I or anything below have been excluded. The exposure time of one soure can be three times more than another sourece. The spectral distribution of the light source and the relative spectral responsibility of the artifact are not considered in the practice. So in case of very light sensitive material, the recommended illuminance is only the referring value and it is indispensable to check the characteristic of susceptibility of each artifacts. Daylighting is prevailing method to solve the psychological need of the visitors. However, it sould transparent, and should not diffused, and the green-house effect must be considered. llluminance uniformity should based on the maximum illuminance to handle the limitation of exposure for the conservation of a large sensitive object such as a painting. Damage index is not absolute reference for selecting the lighting source because it is experimented from the paper of low grade then calculated. Visibility should be increased by reducing the visual noiseand by planning of appropriate luminance contrast. This paper reviews the problems with the previous studies and experiment sand the current exhibition lighting design practice. The plan for museum showcase lighting is to check the susceptibility and to raise the visibility simultaneously.

  • PDF

Contrast-Enhanced Spectral Mammography Versus Ultrasonography: Diagnostic Performance in Symptomatic Patients with Dense Breasts

  • Zhongfei Lu;Cuijuan Hao;Yan Pan;Ning Mao;Xin Wang;Xundi Yin
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.442-449
    • /
    • 2020
  • Objective: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard. Materials and Methods: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained. Results: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US. Conclusion: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.