• Title/Summary/Keyword: Specific Flow Rate

Search Result 548, Processing Time 0.04 seconds

Performance Evaluation of Heat Sink for Cooling of LED Projector (LED 프로젝터 방열용 히트싱크의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeon, Dong-Soon;Kim, Seon-Chang;Son, Kwang-Eun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

Experimental Study of Droplet Characteristics Related to Electrospray Mode (정전분무모드에 관한 액적특성의 실험적 연구)

  • Kim, Ji Yeop;Lee, Doe Hyun;Cho, Ju Hyung;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.26-35
    • /
    • 2022
  • Electrospray is a method of atomizing fluid using high voltage supply and capable of generating continuous flow and coherent size of droplets. Electrical system and properties of fluids has enabled electrospray to have various spray modes. However, its studies have been confined only in Cone jet, which is more stable and easier to manipulate droplets' size than other spraying modes. Therefore, it is necessary to investigate and compare other spraying modes based on experimental parameters and physical properties of fluids. This research paper identified nine different spray modes. It was found out that Sauter Mean Diameter (SMD) is proportional to flow rate of fluids and maximum difference among spray modes was 1.7 times. On the other hand, SMD standard deviation had low variations on specific flow rates of fluids. Pulsed jet mode recorded the largest SMD standard deviation, while Spindle recorded the lowest.

Development of the Seepage Flow Monitoring Method by the Hydraulic Head Loss Rate (수두손실률에 의한 침투류 감시기법 개발)

  • Eam, Sung-Hoon;Kang, Byung-Yoon;Kim, Ki-Wan;Koo, Ja-Ho;Kang, Shin-Ik;Cha, Hung-Youn;Jung, Jae-Hyun;Cho, Jun-Ho;Kim, Ki-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.5
    • /
    • pp.37-48
    • /
    • 2010
  • In this study, the seepage flow monitoring method by the hydraulic head loss rate was developed for the purpose of application to offshore construction site enclosed by cofferdams in which seepage force varies periodically. The amount of the hydraulic head loss rate newly defined in this graph was in a range between 0 and 1. The zero of the rate means the existence of flow with no seepage resistance. The 1 of the rate means no seepage flow through the ground. The closer to 1 the coefficient of determinant in the hydraulic head loss graph is, the more the ground through which seepage water flows is stable. The closer to 0 the coefficient of determinant in the hydraulic head loss graph is, the more the ground through which seepage water flows was unstable and the higher the possibilities of existence of empty space or of occurrence of piping on the seepage flow pass in the ground is. The hydraulic head loss graph makes it possible to monitor sensitively the situation of seepage flow state, and the graph helps to understand easily the seepage flow state at the specific section on the whole cofferdam.

Runner Design and Internal Flow Characteristics Analysis for an Ns=200 Francis Hydro Turbine Model

  • Hwang, Yeong-Cheol;Chen, Zhenmu;Choi, Young-Do;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.8
    • /
    • pp.698-703
    • /
    • 2016
  • Francis hydro turbines have been most widely used throughout the world because of their wide range of head and flow rate applications. In most applications, they are used for high heads and flow rates. Currently, Korea is developing technology for Francis hydro turbine design and manufacture. In order to understand the internal details of Francis hydro turbines further, a new Francis turbine model runner is designed and model internal flow characteristics are investigated. The specific speed of the Francis hydro turbine model runner is $Ns=200m-kW-min^{-1}$. The runner blade is designed successfully according to the port area and one-dimensional loss analysis. The best efficiency point of the Francis hydro turbine model achieves 90% at the design condition. CFD analysis yields a hill chart of the Francis hydro turbine model for use in predicting performance.

Electrochemical Characteristics of Lithium Vanadium Oxide for Lithium Secondary Battery

  • Kim, Hyung-Sun;Cho, Byung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1267-1269
    • /
    • 2010
  • The pure crystalline $Li_{1.1}V_{0.9}O_2$ powder has been prepared by a simple solid state reaction of $Li_2CO_3$ and $V_2O_3$ precursors under nitrogen gas containing 10 mol % hydrogen gas flow. The structure of $Li_{1.1}V_{0.9}O_2$ powder was analyzed using Xray diffraction (XRD) and scanning electron microscope (SEM). The stoichiometric $Li_{1.1}V_{0.9}O_2$ powder was used as anode active material for lithium secondary batteries. Its electrochemical properties were investigated by cyclic voltammetry and constant current methods using lithium foil electrode. The observed specific discharge capacity and charge capacity were 360 mAh/g and 260 mAh/g during the first cycle, respectively. In addition, the cyclic efficiency of this cell was 72.2% in the first cycle. The specific capacity of $Li_{1.1}V_{0.9}O_2$ anode rapidly declines as the current rate increases and retains only 30 % of the capacity of 0.1C rate at 1C rate. The crystallinity of the $Li_{1.1}V_{0.9}O_2$ anode decrease as discharge reaction proceeds. However, the relative intensity of main peaks was almost recovered when the cell was charged up to 1.5 V.

Kinetics of producing ${\beta}$-carotene from Dunaliella salina by Light Limited Turbidostat Cultivation (Dunaliella salina 의 광 제한 현탁 연속배양에 의한 ${\beta}$-carotene 의 생산)

  • Park, Young-Shik;You, Ho-Keum;Ohh, Shang-Jip;Lee, Hyeon-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.4
    • /
    • pp.342-347
    • /
    • 1993
  • It was proved that the cell growth followed a photo-inhibition model in light-limited turbidostat cultivation, having 1.06 (1/h) of maximum specific growth rate and 0.00094(kcal/$cm^2$/h) and 0.063 (kcal/$cm^2$/h) as half saturation and light inhibition constants, repectively. ${\beta}$-carotene production showed a growth related porcess. And the activation energy of Dunaliella salina was roughly estimated as 12.36 (kcal/mole) in employing Arrhenius relationship. It should also point out that relatively much porduction of ${\beta}$-carotene was observed at hight light intensity with yieding 1.04 (mg-carotene/g-dry cell/day) of specific product production rate while the cell growth was decreased. The optimal conditions of producing ${\beta}$-carotene in turbiodostat cultivation were as follows: $7.5{\times}10^{-3}$(kcal/$cm^2$/h)of light intensity, 2 (mM) and 50(mM) of nitrate and sodium bicarbonate concentrations and 100(ml/h) of $CO_2$ flow rate.

  • PDF

Comparison of the Nitrification Efficiencies of Three Biofilter Media in a Freshwater System

  • Harwanto, Dicky;Oh, Sung-Yong;Jo, Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.363-369
    • /
    • 2011
  • Total ammonia nitrogen (TAN) removal efficiencies of a sand filter (SF), polystyrene microbead filter (PF), and Kaldnes bead filter (KF) media were evaluated under ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$. The volume of each filter media tested was 7 L, and the water flow rate for all filter media was 24 L/min. The specific surface areas of the SF, PF, and KF were 7,836, 3,287, and 500 $m^2/m^3$, respectively. Sand was fluidized and the other two media were trickle filtered. The volumetric TAN removal rate increased with increasing ammonia loading rate for all filter media. Mean volumetric TAN removal rates under the ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$ in SF (39.3, 168.6, and 322.7 g $m^{-3}day^{-1}$, respectively) were higher than those in PF (35.0, 157.4, and 310.5 g $m^{-3}day^{-1}$, respectively) and KF (32.1, 142.5, and 288.1 g $m^{-3}day^{-1}$, respectively). These results were related to differences in the specific surface areas of the filter media. PF was the most economic media for efficiently removing TAN.

A Study on the Performance of Home Clothes Dryer using Thermoelectric Module (열전소자를 이용한 가정용 의류 건조기의 성능에 관한 실험적 연구)

  • Lee, Min-Jae;Gong, Sang-Un;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2073-2078
    • /
    • 2007
  • This study was performed to develop a dryer for home clothes using thermoelectric module. The thermoelectric module was used as a heat source and a dehumidification device because it has heating part and cooling part at once. To design for maximizing the energy efficiency and the rate of dehumidification, the parameters of the dryer using thermoelectric module are heat capacity and air flow rate. This study showed that the thermoelectric module can be used in the clothes dryer and energy efficiency of clothes dryer be better than that of electric heating dryer.

  • PDF

Propane Reforming in Gliding Arc Plasma Reformer for SynGas Generation (합성가스 생성을 위한 글라이딩 아크 플라즈마 개질기에서 프로판 개질)

  • Yang, Yoon-Cheol;Chun, Young-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.869-875
    • /
    • 2009
  • The purpose of this paper is to investigate the optimal condition of the syngas production by reforming of propane using Gliding arc plasma reformer. The gliding arc plasma reformer in 3 phases has been newly designed and developed with a quick starting and fast response time. It can be applicable to the various types of fuels (Hydrocarbons $C_xH_y$), and it has a high conversion rate of fuels and high production of hydrogen. The parametric screening studies were carried out according to the changes of a steam feed amount i.e., steam/carbon ratio, total gas flow rate and input electric power. The optimum operating conditions were S/C ratio 2.8, total gas flow rate of 14 L/min and input electric power of 2.4 kW. The result of optimum operating conditions showed the 55 % $H_2$, 14 % CO, 15 % $CO_2$, 10 % $C_3H_8$ and 4 % $CH_4$. Also, $C_3H_8$ conversion, $H_2$ yield and $H_2$ selectivity were 90 %, 42 %, 15 %, respectively. The energy efficiency and specific energy requirements were 37 % and 334 kJ/mol respectively.

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF