초전도여자기를 이용한 초전도전원장치의 설계.제작 및 특성해석 (Design, Manufacture and Characteristic Experiment of a Superconducting power Supply with Superconducting Excitation Coil)

  • 추용;김호민;윤용수;고태국;한태수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.14-18
    • /
    • 2000
  • This paper describes a series of experiments to investigate the operational characteristics of a superconducting power supply with superconducting excitation coil. In this experiment, the superconducting excitation coil is introduced to control the pole-flex in the air gap of the machine. The operating current of the superconducting powder supply is designed to have the value of 300 [A] for the rotational speed of 600 rpm. Sensors installed on the Nb sheet yield the information on the spatial and temporal behaviors of the magnetic field in spot and on the characteristics of the superconducting power supply.

  • PDF

지뢰탐지를 위한 ECR 플라즈마에서 타깃에 고전압 DC 펄스 인가시 전압-전류 특성 분석 (I-V Characteristics of Negatively DC Pulsed Target in ECR Plasma for Landmine Detection)

  • 김성봉;이희재;박승일;유석재;조무현;한승훈;임병옥
    • 한국표면공학회지
    • /
    • 제47권1호
    • /
    • pp.53-56
    • /
    • 2014
  • I-V characteristics of a cylindrical target in an ECR plasma were studied for sheath spatial evolutions when the target was pulsed biased to a high negative potential. The magnetic field effects on sheath thickness and sheath boundary speed were investigated by comparison between the experimental results and the theoretical results using the Child-Langmuir sheath model. The results showed that the magnetic field suppressed electron motion away from the target so that sheath thickness and sheath boundary speed decreased.

Laser Thomson Scattering Measurements and Modelling on the Electron Behavior in a Magnetic Neutral Loop Discharge Plasma

  • Sung, Youl-Moon;Kim, Hee-Je;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권4호
    • /
    • pp.107-112
    • /
    • 2001
  • Laser Thomson scattering measurements of electrom temperature and density in a neutral loop discharge (NLD) plasma were performed in order to reveal the electron behavior around the neutral loop (NL). The experimental results were examined by using a simulation model that included effects of a three dimensional electromagnetic field with spatial decay of the RF electric field, and the limitation of the spatial extent of the electron motion and collision effect. From the experiments and modeling of the electron behavior, it was found that NLD plasma posses the electron temeprature $T_{e}$ and density ne peaks around the NL is essential for the formation of plasma. Also, the optimum condition of plasma production could be simply estimated by the calculation of $U_{av}$ and $F_{0}$././.

  • PDF

Modeling of a Scan Type Magnetic Camera Image Using the Improved Dipole Model

  • Hwang Ji-Seong;Lee Jin-Yi
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1691-1701
    • /
    • 2006
  • The scan type magnetic camera is proposed to improve the limited spatial resolution due to the size of the packaged magnetic sensor. An image of the scan type magnetic camera, ${\partial}B/{\partial}x$ image, is useful for extracting the crack information of a specimen under a large inclined mag netic field distribution due to the poles of magnetizer. The ${\partial}B/{\partial}x$ images of the cracks of different shapes and sizes are calculated by using the improved dipole model proposed in this paper. The improved dipole model uses small divided dipole models, the rotation and relocation of each dipole model and the principle of superposition. Also for a low carbon steel specimen, the experimental results of nondestructive testing obtained by using multiple cracks are compared with the modeling results to verify the effectiveness of ${\partial}B/{\partial}x$ modeling. The improved dipole model can be used to simulate the LMF and ${\partial}B/{\partial}x$ image of a specimen with complex cracks, and to evaluate the cracks quantitatively using magnetic flux leakage testing.

자기공명영상 시스템의 양자화잡음 분석 (Analysis of Quantization Noise in Magnetic Resonance Imaging Systems)

  • 안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권1호
    • /
    • pp.42-49
    • /
    • 2004
  • 목적 : 자기공명영상시스템에서 양자화잡음을 분석하였다. 신호대양자화잡음비를 이론적으로 유도하였고 다양한 자기공명영상시스템에서 신호대양자화잡음비를 계산하였다. 이러한 계산으로부터 고자장영상시스템에서는 양자화잡음이 전체시스템의 신호대잡음비를 결정짓는 주된 잡음원이 될 수 있음을 보였다. 하드웨어의 교체없이 양자화잡음을 줄일 수 있는 방법들을 제시하였다. 대상 및 방법 : 자기공명영상에서 사용되는 Fourier 영상기법에서는 위상 및 주파수 인코딩 방법으로 자기공명신호를 공간주파수 형태의 신호로 변환하여 측정하게 된다. 따라서 공간주파수 영역에서 발생하는 양자화잡음을 재구성된 영상에서의 신호대양자화잡음비로 나타내었다. 컴퓨터 시뮬레이션 및 실험을 통하여 유도된 식의 타당성을 보였다. 결과 : 유도된 식을 이용하여 다양한 주 자장 및 수신 시스템에 대하여 신호대양자잡음비를 계산하였다. 양자화잡음은 신호의 크기에 비례하여 증가하므로 상대적으로 신호가 큰 고자장 시스템에서 보다 큰 문제점으로 부각될 수 있다. 많은 수신 시스템에서 채택하고 있는 16 bits/샘플 양자기로는 양자화 잡음이 고자장 시스템에서 기대되는 신호대잡음비의 향상을 제한할 수 있는 주된 잡음원이 될 수 있음을 보였다. 결론 : fMRI나 spectroscopy를 위하여 자기공명영상의 주 자장은 지속적으로 높아지고 있다. 고자장에서는 신호가 커지고, susceptibility와 스펙트럼의 분리가 커져서 fMRI 나 spectroscopy에 유리한 면이 많다. 양자화잡음은 신호의 크기에 비례하여 증가하기 때문에 만약 양자기의 변환 비트가 충분히 크지 않을 경우 양자화잡음이 커져 신호의 증가에 비례하는 신호대잡음비의 향상을 이룰 수 없다. 이 논문에서는 신호대양자화잡음비를 이론적으로 유도하고, 다양한 자장의 세기 및 수신 시스템에 대하여 신호대양자화잡음비를 계산함으로써 고자장에서, 특히 상대적으로 신호가 큰 3차원영상에서 , 양자화잡음이 전체 시스템의 신호대잡음비를 제한할 수 있는 주된 잡음원이 될 수 있음을 보였다. 근원적인 해결책은 아닐 수 있으나 oversampling과 에코의 센터를 비껴가는 샘플링으로 하드웨어의 향상없이 양자화잡음을 줄일 수 있는 방법을 제시하였다.

  • PDF

부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법 (Fast MR Imaging Technique by Using Locally-Linear Gradient Field)

  • 양윤정;이종권
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF

저온 증착된 불소도핑 주석 산화 박막의 광학적·전기적 특성 (Optical and Electrical Properties of Fluorine-Doped Tin Oxide Prepared by Chemical Vapor Deposition at Low Temperature)

  • 박지훈;전법주
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.517-524
    • /
    • 2013
  • The electrical and optical properties of fluorine-doped tin oxide films grown on polyethylene terephthalate film with a hardness of 3 using electron cyclotron resonance plasma with linear microwave of 2.45 GHz of high ionization energy were investigated. Fluorine-doped tin oxide films with a magnetic field of 875 Gauss and the highest resistance uniformity were obtained. In particular, the magnetic field could be controlled by varying the distribution in electron cyclotron deposition positions. The films were deposited at various gas flow rates of hydrogen and carrier gas of an organometallic source. The surface morphology, electrical resistivity, transmittance, and color in the visible range of the deposited film were examined using SEM, a four-point probe instrument, and a spectrophotometer. The electromagnetic field for electron cyclotron resonance condition was uniformly formed in at a position 16 cm from the center along the Z-axis. The plasma spatial distribution of magnetic current on the roll substrate surface in the film was considerably affected by the electron cyclotron systems. The relative resistance uniformity of electrical properties was obtained in film prepared with a magnetic field in the current range of 180~200A. SEM images showing the surface morphologies of a film deposited on PET with a width of 50 cm revealed that the grains were uniformly distributed with sizes in the range of 2~7 nm. In our experimental range, the electrical resistivity of film was able to observe from $1.0{\times}10^{-2}$ to $1.0{\times}10^{-1}{\Omega}cm$ where optical transmittance at 550 nm was 87~89 %. These properties were depended on the flow rate of the gas, hydrogen and carrier gas of the organometallic source, respectively.

INTENSITY AND DOPPLER VELOCITY OSCILLATIONS IN PORE ATMOSPHERE

  • Cho, Kyung-Suk;Bong, Su-Chan;Nakariakov, Valery;Lim, Eun-Kyung;Park, Young-Deuk;Chae, Jongchul;Yang, Heesu;Park, Hyung-Min;Yurchyshyn, Vasyl
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.98-98
    • /
    • 2014
  • Due to the simple vertical structure of magnetic field, pores can be exploited to study the transport of mechanical energy by waves along the magnetic field to the chromosphere and corona. For a better understanding of physics of pores, we have investigated chromospheric traveling features running across two merged pores from their centers at the speed about 55 km s-1, in the active region AR 11828. The pores were observed on 2013 August 24 by using high time, spatial, and spectral resolution data from the Fast Imaging Solar Spectrograph (FISS) of the 1.6 meter New Solar Telescope (NST). We infer a LOS velocity by applying the bisector method to the Ca II $8542{\AA}$ band and $H{\alpha}$ band, and investigate intensity and the line-of-sight velocity changes at different wavelengths and different positions at the pores. We find that they have 3 minutes oscillations, and the intensity oscillation from the line center is preceded by that from the core ($-0.3{\AA}$) of the bands. There is no phase difference between the intensity and the LOS velocity oscillations at a given wavelength. The amplitude of LOS velocity from near the core spectra is greater than that from the far core spectra. These results support the interpretation of the observed wave as a slow magnetoacoustic wave propagating along the magnetic field lines in the pores. The apparent horizontal motion and a sudden decrease of its speed beyond the pores can be explained by the projection effect caused by inclination of the magnetic field with a canopy.

  • PDF

Thrust Performance and Plasma Acceleration Process of Hall Thrusters

  • Tahara, Hirokazu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.262-270
    • /
    • 2004
  • Basic experiments were carried out using the THT-IV low-power Hall thruster to examine the influences of magnetic field shape and strength, and acceleration channel length on thruster performance and to establish guidelines for design of high-performance Hall thrusters. Thrusts were measured with varying magnetic field and channel structure. Exhaust plasma diagnostic measurement was also made to evaluate plume divergent angles and voltage utilization efficiencies. Ion current spatial profiles were measured with a Faraday cup, and ion energy distribution functions were estimated from data with a retarding potential analyzer. The thruster was stably operated with a highest performance under an optimum acceleration channel length of 20 mm and an optimum magnetic field with a maximum strength of about 150 Gauss near the channel exit and with some shape considering ion acceleration directions. Accordingly, an optimum magnetic field and channel structure is considered to exist under an operational condition, related to inner physical phenomena of plasma production, ion acceleration and exhaust plasma feature. A new Hall thruster was designed with basic research data of the THT-IV thruster. With the thruster with many considerations, long stable operations were achieved. In all experiments at 200-400 V with 1.5-3 mg/s, the thrust and the specific impulse ranged from 15 to 70 mN and from 1100 to 2300 see, respectively, in a low electric power range of 300~1300 W. The thrust efficiency reached 55 %. Hence, a large map of the thruster performance was successfully made. The thermal characteristics were also examined with data of both measured and calculated temperatures in the thruster body. Thermally safe conditions were achieved with all input powers.

  • PDF

셀룰라 휴대폰에 의한 인체 두부의 SAR 해석 (Analysis of SAR in a Human Head for a Cellular Phone)

  • 이애경;최형도;김진석
    • 한국전자파학회논문지
    • /
    • 제9권6호
    • /
    • pp.776-787
    • /
    • 1998
  • 835 MHz에서 동작하는 셀룰라 휴대폰에 의한 인체 두부내의 1 g 및 10 g 평균 비홉수율(specific absorption rate, SAR)을 해석한다. 사용되는 수치방법은 총 전자기장 유한차분 시간영역(finite-difference time-domain, FDTD) 기법이다. 전화기는 도체박스, 플라스틱 케이스 그리고 모노폴 안테나와 나선형 안테나 로 구성된 whip 안테나로 모의되었다. 공간 정밀도 3 mm의 이산적 인체두부 모델은 MRI(Magnetic Resonance Imaging), CT(computerized tomography) 그리고 해부학적 이미지에 기초한 것이다 안테나를 뽑은 전화기와 접은 전화기에 대한 근역장 및 원역장 복사 패턴이 분석되었다. SAR 평가를 위한 재현성 있는 기법을 제공하기 위해 조직내의 1 g 또는 10 g의 질량을 갖는 체적을 취하는 두 가지 방법을 제안하고 비교 한다.