• 제목/요약/키워드: Sparkover voltage

검색결과 16건 처리시간 0.025초

Optimal Design of a Follow Current Disconnector for DC Arresters in Traction Vehicles

  • Wang, Guoming;Kim, Sun-Jae;Park, Seo-Jun;Kil, Gyung-Suk;Ji, Hong-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권5호
    • /
    • pp.289-292
    • /
    • 2016
  • This paper dealt with the optimal design of a follow current disconnector for DC arresters used in electric traction vehicles. The disconnector separates the ground lead from an arrester to prevent a line-to-ground fault of an aged arrester and should not affect the operation and function such as the reference and the clamping voltage of the connected arrester. The designed disconnector is composed of a resistor, a spark gap, and a cartridge. The results showed that the sparkover voltage increased with the gap distance whereas the reference voltage was almost the same as that without the disconnector. The sparkover voltage was 3.95 kV when the gap distance was 0.5 mm. Regardless of the gap distance, the reference and the clamping voltage of the assembled disconnector with an arrester were measured to be the same as those of the arrester alone.

Reynolds Number를 변수로한 유동공기의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge in Flowing Air with Reynolds Number's Variable)

  • 김영훈;이동인;이광식;김상구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.41-46
    • /
    • 1990
  • This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re to 10.52$\times$104(Re). Also, we investigated changes of dis-charge pattern for constant input power by adjustment of the Re. The important results obtained from this paper are as followers. The maxinum sparkover voltage of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Re.

  • PDF

Flowing Gas의 방전특성에 관한 연구 (A Study on Sparkover Discharge Characteristics of Flowing Gas)

  • 오재열;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.296-299
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing gas ranging from 0[m/s] to 30[m/s] under the needle-rod gap. The important results obtained from this paper are as followers. 1. The maximum sparkover voltage of flowing gas are about 3.1[kv](d=1[cm], 5.4[kv](d=2[cm]), 8.1[kv](d=3[cm]) higher than those of static gas 2. The empirical equation obtained from this experiment is [%]$\frac{Vs}{Re}=A\;log_{10}\;Re+B$ where A=$-7.79{\times}10$ B=$5.60{\times}10^2$ 3. The duration time of sparkover decreases with increasing the Reynolds number. 4. The discharge pattern can be controlled by adjustment of the Reynolds number

  • PDF

Reynolds Number를 변수(變數)로한 유동공기(流動空氣)의 방전특성(放電特性)에 관한 연구 (Characteristics of Sparkover Discharge in Flowing Air with Reynolds Numbers' Variable)

  • 김영훈;오재열;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.286-288
    • /
    • 1990
  • This paper reports the characteristics of sparkover discharge in flowing air ranging from 0[m/s] to 30 [m/s] under the needle-needle gap. Flowing air duct of this investigation is circular tube. The important results obtained form this study are as follows. 1. the ratio of sparkover voltage to the Reynolds number decreases with increasing the Reynolds number. 2. The duration time of sparkover(t) decreases with increasing the Reynolds number. 3. the empirical equation obtained form this experiment is [ %]${\frac{Vs}{Re}}$ = A + $B{\varepsilon}^{C.Re}$ where A = 10.2 b = 125 c = -4.66 ${\times}$ $10^{-5}$

  • PDF

이용률을 이용한 과냉질소 냉각시스템용 절연가스의 절연특성에 관한 연구 (A Study on the Dielectric Characteristics of Insulation Gases for a Sub-cooled Liquid Nitrogen System)

  • 강형구;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.52-55
    • /
    • 2010
  • A sub-cooled liquid nitrogen system is known as a promising method to develop high voltage superconducting apparatuses such as superconducting fault current limiters (SFCLs) and superconducting cables. To develop a high voltage superconducting machine adopting the sub-cooled liquid nitrogen system with a constant pressure. injecting a non-condensable gas is indispensable. In this study. the dielectric characteristics of insulation gases are investigated and analyzed by using electric utilization factors ($\xi$). It is found that the maximum electric field at sparkover that occurs with 50 % probability. $E_{MAX.50%}$ exponentially decreases as the S increases. This means that the $E_{MAX.50%}$ at sparkover can be estimated with the $E_{MAX.50%}$

Reynolds Number를 변수로한 유동공기의 방전특성 (Characteristics of Sparkover Discharge in Flowing Air with the variation of Reynolds Number)

  • 김영헌;이광식;이동인
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제5권2호
    • /
    • pp.37-48
    • /
    • 1991
  • 본 연구에서는 Reynold수가 $0-10.52{\times}10^4$의 범위에서 유동공기중의 전로파괴의 특성을 연구하였다. 또한 일정한 입력전력에서 Reynold수의 조정에 의한 방전 Pattern의 변화를 연구하였다. 그리고 실험에 사용된 유로는 원통관이다. 측정부에서의 흐름은 완전히 발달한 층류로 이루어졌다. 본 연구에서 얻은 중요한 결과는 다음과 같다. 유동공기중의 전로파괴는 공기의 흐름장 이론에 의해 분석이 가능하며 전로파괴전압은 Reynold수가 $3{\times}10^2$-$4{\times}10^4$의 범위에서 거의 최대값을 나타낸다. 유동 공기중의 최대전로파괴전압은 정지시보다 평굼 6.3[kV]높게 나타났다. 방전 pattern은 Reynold수의 조정에 의하여 제어할 수 있었다.

  • PDF

Sparkover Voltage Estimation of Standard Sphere Gaps for Negative Polarity by Calculation of Ionization Index

  • Nishikori, Yasuo;Kojima, Soji;Kouno, Teruya
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권2호
    • /
    • pp.45-50
    • /
    • 2004
  • The field utilization factor (equation omitted) (the mean electric field / the maximum electric field) of standard sphere gaps was calculated by the charge simulation method, taking into account the ground plane and shanks. n changes mainly with g/r and slightly with 1$_1$, 1$_2$ and 1, where D=2r is the sphere diameter, g is the gap length, 1$_1$ and 1$_2$, respectively, are the lengths of the upper and lower shank, and t is the shank diameter. Generally, (equation omitted) increases as 1$_1$,1$_2$ and t each becomes larger. IEC standard 60052(2002) limits t$\leq$0.2D 1$_1$$\geq$1D and prescribes A=1$_2$+D+g where A is the height of the spark point on the upper sphere. Therefore, (equation omitted) is the largest when A=9D and the smallest when A=3D. The simple equation of a straight line, (equation omitted)=1- (g/3r), can generally be used as a representative value of (equation omitted) for a wide variety of sphere diameters that are permitted by the IEC standard. The maximum electric field E$_{m}$ at sparkover of standard air gaps has also been calculated by the relation E$_{m}$=V/(equation omitted)g). E$_{m}$ describes a U-curve for g/r, up to the sphere diameter of 1 m. Moreover, for 1.5-m and 2-m diameters and especially .for negative polarity, sparkover voltages have been calculated by integration of the ionization index.index.

온도변화를 고려한 유동기체의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge In Flowing Gas with Variation of Temperature)

  • 김상구;오재열;송현직;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.310-313
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing air with variation of Temperature(T). Also, We studied changes of discharge pattern for constant input power by adjustment of the Reynolds number(Re) and T. The essentiales of this paper are as followers. The invaluable equation obtained from this experiment is [%]$\frac{Vs}{Re}$=A+B${\varepsilon}^{c{\cdot}Re}$ where A=10.5 B=120 $C=-3.00{\times}10^{-5}$ Breakdown Voltage for Variation of temperature in static air is given by expression Vs = K (23.98 ${\rho}$d+6.8 ${\sqrt}{{\rho}d}$)[kV] The discharge pattern can be controlled by adjustment of the Reynolds number.

  • PDF

온도변화를 고려한 유동공기의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge In Flowing Air With Variation of Temperature)

  • 김상구;오재열;송현직;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.28-32
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing air with variation of Temperature(T). Also, We studied changes of discharge pattern for constant input power by adjustment of the reynolds number(Re) and T. the essentials of this paper are as followers. The invaluable equation obtained from this experiment is [%] {{{{ { Vs} over {Re } = A·LOG10 Re + B}}}} w here A,B : constant Breakdown Voltage for variation of temperature at 1[m/s] is given by expression Vs = K(23.98 pd + 6.8{{{{ SQRT { pd} }}}}) [kV] where K = 0.331 The discharge pattern can be controlled by adjustment of the Reynolds number

  • PDF

PST측면에서의 과전류 보호용PTC 소자의 개념 정립 및 Failure-Mode 분석 (The Conception & Fail-Mode Analysis of PTC Thermistor for Over-Current Protection)

  • 박준호
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 춘계학술대회
    • /
    • pp.67-75
    • /
    • 2001
  • Circuitry to be connected to a Telecommunication Network consists of SELV CIRCUITS or TNV CIRCUITS. So International Standards, like as ITU-T Recommendation K.11, UL 1950, CSA C22.2 950 have been taken to reduce the risk that the Overvoltages from the power lines and from electrictraction lines, that may be received from the telecommunication network. Legal requirements may exist regarding permission to connect equipment having PTC components to a telecommunication network. Surge suppressors that bridge the insulation shall have a minimum d.c. sparkover voltage of 1.6 times the rated voltage or 1.6 times the upper voltage of the tared voltage range of the equipment. If left in place during electric strength testing of insulation, they shall not be damaged. In this work, The Conception & Fail-Mode Analysis of PTC components for Over-Current Protection is proposed. It guarantees the protection for PL Claim about this Subject.

  • PDF