• Title/Summary/Keyword: Space scan

Search Result 263, Processing Time 0.032 seconds

Developing a method of processing terrestrial laser scan data for efficient extraction of tunnel cross sections (효율적인 터널 내공 단면 추출을 위한 지상 레이저 스캔 자료 처리기법 개발)

  • Han, Soo-Hee;Cho, Seong-Ha;Kim, Sang-Min;Heo, Joon;Sohn, Hong-Gyoo;You, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.239-245
    • /
    • 2010
  • The present study is about an efficient extraction of tunnel cross sections from huge point cloud achieved by a terrestrial laser scanner. A method, using a hash-based data structure, is introduced, by which point clouds, potentially composing cross sections, are extracted along a tunnel center line. The center line is estimated by linking points which are drawn in the middle of pseudo cross sections based on the hash-based data structure. Point clouds of a same thickness are extracted at a same interval along the center line. In result, it took less than 3 seconds and 124 MB of memory to extract, out of the 7.5 million points, the point clouds of 1 m interval and 0.1 m thickness. A manual operation, however, was needed to fix the outliers on the center line and to select both start and end points on it.

A new efficient algorithm for test pattern compression considering low power test in SoC (SoC환경에서의 저전력 테스트를 고려한 테스트 패턴 압축에 대한 효율적인 알고리즘)

  • 신용승;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.85-95
    • /
    • 2004
  • As the design complexity increases, it is a major problem that the size of test pattern is large and power consumption is high in scan, especially system-on-a-chip(SoC), with the automatic test equipment(ATE). Because static compaction of test patterns heads to higher power for testing, it is very hard to reduce the test pattern volume for low power testing. This paper proposes an efficient compression/decompression algorithm based on run-length coding for reducing the amount of test data for low power testing that must be stored on a tester and be transferred to SoC. The experimental results show that the new algorithm is very efficient by reducing the memory space for test patterns and the hardware overhead for the decoder.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Morgagni Hernia in a 3-year Old Boy - a Case Report - (3세 남아에서 발생한 Morgagni 탈장 - 1예 보고 -)

  • Jeong, Hye-Yeon;Kim, Ae-Suk;Choi, Sung-Min;Park, Jin-Young
    • Advances in pediatric surgery
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2007
  • A 3-year-old boy with purulent otitis media received a chest radiograph as the part of a routine work up. The patient was normal appearing, in no acute distress. The patient's lung and heart sounds were clear and normal. The patient's abdomen was soft, non-distended, and non-tender. An anterior cardiophrenic mass was incidentally identified on the lateral chest radiograph. A computed tomography scan demonstrated a diaphragmatic hernia with bowel loops in the retrosternal space. An exploratory operation revealed a diaphragmatic defect (4 cm in diameter) on the left side of the falciform ligament, through which transverse colon was protruded. There was no hernia sac, and the defect was closed with interrupted No. 2 silk sutures. The child was discharged on the 8th postoperative day without any complications. During 6 months of follow-up period, recurrence was not noticed.

  • PDF

Crystal Structure of Byakangelicin ($C_{17}H_{18}O_{7}$)

  • Kim, Yang-Bae;Oh, Yong-Ho;Park, Il-Yeung;Shin, Kuk-Hyun
    • Archives of Pharmacal Research
    • /
    • v.25 no.3
    • /
    • pp.275-279
    • /
    • 2002
  • The crystal structure of byakangelicin, one of furanocoumarin aldose reductase inhibitors, was determined by X-ray diffraction method. The crystal is triclinic, with a=8.114(1), b=10.194(1), $c=11.428(1)\AA,{\;}{\alpha}=111.50(1),{\}{\beta}=95.57(1),{\}{\gamma}=112.52(1)^{circ},{\;}D_x=1.41,{\;}D_m=1.39{\;}g/cm^3$, space group P1 and Z=2. The intensity data were collected by ${\omega}-2{\theta}$ scan method with $CuK_{a}$ radiations. The structure was solved by direct method and refined by full matrix least-squares procedure to the final R-value of 0.056. There are two molecules with different conformations in an asymmetric unit. The molecules are kept by two intermolecular O-HO type hydrogen bonds and van der Waal's forces in the crystal. The absolute configuration of the molecules was estimated to S-form by the 'Eta refinement' procedure.

A MAP Estimate of Optimal Data Association in Multi-Target Tracking (다중표적추적의 최적 데이터결합을 위한 MAP 추정기 개발)

  • 이양원
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.3
    • /
    • pp.210-217
    • /
    • 2003
  • We introduced a scheme for finding an optimal data association matrix that represents the relationships between the measurements and tracks in multi-target tracking (MIT). We considered the relationships between targets and measurements as Markov Random Field and assumed a priori of the associations as a Gibbs distribution. Based on these assumptions, it was possible to reduce the MAP estimate of the association matrix to the energy minimization problem. After then, we defined an energy function over the measurement space that may incorporate most of the important natural constraints. To find the minimizer of the energy function, we derived a new equation in closed form. By introducing Lagrange multiplier, we derived a compact equation for parameters updating. In this manner, a pair of equations that consist of tracking and parameters updating can track the targets adaptively in a very variable environments. For measurements and targets, this algorithm needs only multiplications for each radar scan. Through the experiments, we analyzed and compared this algorithm with other representative algorithm. The result shows that the proposed method is stable, robust, fast enough for real time computation, as well as more accurate than other method.

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

Effectual Method FOR 3D Rebuilding From Diverse Images

  • Leung, Carlos Wai Yin;Hons, B.E.
    • 한국정보컨버전스학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.145-150
    • /
    • 2008
  • This thesis explores the problem of reconstructing a three-dimensional(3D) scene given a set of images or image sequences of the scene. It describes efficient methods for the 3D reconstruction of static and dynamic scenes from stereo images, stereo image sequences, and images captured from multiple viewpoints. Novel methods for image-based and volumetric modelling approaches to 3D reconstruction are presented, with an emphasis on the development of efficient algorithm which produce high quality and accurate reconstructions. For image-based 3D reconstruction a novel energy minimisation scheme, Iterated Dynamic Programming, is presented for the efficient computation of strong local minima of discontinuity preserving energyy functions. Coupled with a novel morphological decomposition method and subregioning schemes for the efficient computation of a narrowband matching cost volume. the minimisation framework is applied to solve problems in stereo matching, stereo-temporal reconstruction, motion estimation, 2D image registration and 3D image registration. This thesis establishes Iterated Dynamic Programming as an efficient and effective energy minimisation scheme suitable for computer vision problems which involve finding correspondences across images. For 3D reconstruction from multiple view images with arbitrary camera placement, a novel volumetric modelling technique, Embedded Voxel Colouring, is presented that efficiently embeds all reconstructions of a 3D scene into a single output in a single scan of the volumetric space under exact visibility. An adaptive thresholding framework is also introduced for the computation of the optimal set of thresholds to obtain high quality 3D reconstructions. This thesis establishes the Embedded Voxel Colouring framework as a fast, efficient and effective method for 3D reconstruction from multiple view images.

  • PDF

The Crystal and Molecular Structure of Thiamphenicol

  • Shin, Whan-chul;Kim, Sang-soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.2
    • /
    • pp.79-83
    • /
    • 1983
  • The structure of thiamphenicol, one of the congeners of chloramphenicol which is a well-known antibiotic, has been determined by single crystal x-ray diffraction techniques. The crystal structure was determined using diffractometer data obtained by the $2{\theta}:{\omega}$ scan technique with $MoK{\alpha}$ radiation from a crystal having space group symmetry $P2_{1}2_{1}2_{1}$, and unit cell parameters a = 5.779, b = 15.292 and c = 17.322 ${\AA}$ . The structure was solved by direct methods and refined by least squares to an R = 0.070 for the 2116 reflections. The overall V-shaped conformation of thiamphenicol revealed in this study is consistent with those from the crystallographic studies and the proposed models from the theoretical and nmr studies of chloramphenicol. However there is no intramolecular hydrogen bond and the propanediol moiety is fully extended in the thiamphenicol molecule, while the crystal structures of chloramphenicol show the existence of the hydrogen bond between the two hydroxyl groups of the propanediol moiety forming an acyclic ring. All of the thiamphenicol molecules in the crystal are linked by a threedimensional hydrogen bonding network.

The Crystal Structure of Cholesteryl Aniline

  • Park, Young-Ja;Kim, Sang-Soo;Lee, Seung-Bun
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.5
    • /
    • pp.427-430
    • /
    • 1990
  • Cholesteryl aniline ($C_{33}H_{51}N$) is monoclinic, space group $P2_1$, with a = 9.020(3), b = 6.000(1), c = 27.130(9)${\AA},\;{\beta} = 98.22(2)^{\circ}$, Z = 2, Dc = 1.06 g/cm$^3$ and Dm = 1.04 g/cm$^3$. A diffraction data set was collected with Mo-$K_{\alpha}$ radiation (${\lambda} = 0.7107 {\AA}$) on a diffractometer with a graphite monochromator to a maximum 2${\theta}$ value of 50$^{\circ}$, by the ${\omega}-2{\theta}$ scan technique. The coordinates of the non-hydrogen atoms and their anisotropic temperature factors were refined by full-matrix least-squares methods to final R of 0.058. In cholesteryl group, bond distances were normal except in tail part, where high thermal vibration resulted in apparent shortening of the C-C distances. The crystal structure consists of bilayers of thickness $d_{001} = 27.13 {\AA}$, in each of which there is the tail to tail arrangement of molecules aligned in the unit cell with their long axes approximately parallel to the [104] axis. The two halves of the double layer are related to each other by the screw axis.