• Title/Summary/Keyword: Source position detection

검색결과 93건 처리시간 0.031초

A prototype of the SiPM readout scintillator neutron detector for the engineering material diffractometer of CSNS

  • Yu, Qian;Tang, Bin;Huang, Chang;Wei, Yadong;Chen, Shaojia;Qiu, Lin;Wang, Xiuku;Xu, Hong;Sun, Zhijia;Wei, Guangyou;Tang, Mengjiao
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1030-1036
    • /
    • 2022
  • A high detection efficiency thermal neutron detector based on the 6LiF/ZnS(Ag) scintillation screens, wavelength-shifting fibers (WLSF) and Silicon photomultiplier (SiPM) readout is under development at China Spallation Neutron Source (CSNS) for the Engineering Material Diffractometer (EMD).A prototype with a sensitive volume of 180mm×192mm has been built. Signals from SiPMs are processed by the self-design Application Specific Integrated Circuit (ASIC). The performances of this detector prototype are as follows: neutron detection efficiency could reach 50.5% at 1 Å, position resolution of 3, the dark count rate <0.1Hz, the maximum count rate >200KHz. Such detector prototype could be an elementary unit for applications in the EMD detector arrays.

운전자 눈동자 위치를 이용한 이러 자동 조절 시스템 (Automatic Mirror Adjustment Systems Using the Location of the Driver`s Pupils)

  • 노광현;박기현;조준수;한민홍
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.523-531
    • /
    • 2001
  • This paper describes and automatic mirror adjustment system that rotates a pair of side mirrors and the room mirror of a car to the optimal position for a driver by using the locating of the driver\`s pupils. A stereo vision system measures 3D coordinates of a pair pupils by analyzing the input images of stereo B/W CCD cameras mounted on the instrument panel. this system determines the position angle of each mir-ror on the basis of information about the location of the pupils and rotates each mirror to the appropriate po-sition by mirror actuators. The vision system can detect the driver\`s pupils regardless of whether it is day-time or nighttime by virtue of an infrared light source. information about the pair of nostrils in used to im- prove the correctness of pupil detection. This system can adjust side mirrors and the room mirror automati- cally and rapidly by a simple interface regardless of driver replacement of driver\`s posture. Experiment has shown this to be a new mirror adjustment system that can make up for the weak points of previous mirror adjustment systems.

  • PDF

Pulsed CW 신호를 사용하는 수중 음원의 위치 추정을 위한 시간지연차 추정법 (Position Estimation of Underwater Acoustic Source Using Pulsed CW Signal)

  • 최영근;손권;도경철;김기만
    • 한국음향학회지
    • /
    • 제23권7호
    • /
    • pp.514-520
    • /
    • 2004
  • 수중에서 음원의 위치 추정을 위해 적용되어지는 기법으로써 시간지연차 (TDOA : Time Difference Of Arrival) 추정, 빔 형성 기법, 고 분해능 기법 등이 있다. 본 논문에서는 상대적으로 적은 수의 센서를 사용하여 주파수 영역에서 시간 지연차 추정에 사용되는 MCPSP (Modified Cross Power Spectrum Phase) 함수를 이용하였다. 그러나 MCPSP 함수에 기반한 방법은 CW (Continuous Wate) 신호를 대상으로 할 경우 추정 성능이 크게 떨어진다. 이에 본 논문에서는 Pulsed CW신호를 사용하는 수중 음원의 위치를 추정하기 위해 단 구간 (short-time) 에너지 검출을 이용하여 핑(ping)의 경계 영역을 포함하는 세그먼트를 구성하고 이로부터 MCPSP 함수를 구하는 방법을 제안하였다. 제안된 방법의 성능에 대한 이론적인 접근과 함께 다양한 환경 하에서 분석이 이루어졌다.

Non-conventional 센서를 이용한 MV급 전력케이블의 부분방전 측정 (Partial Discharges Detection for MV Cables using Non-conventional Sensors)

  • 김종열;이영조;조성주;남정학;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1604-1605
    • /
    • 2011
  • This paper deals with the partial discharge detection in order to recognize with three different nature of artificial defects using non-conventional HF-VHF PD sensor of which two measuring position are chosen along the 22.9kV XLPE power cable specimen. The response of the sensor under investigation has been observed be significantly affected by the cable length from the PD sources. As a result, it seems that the detecting sensor position is very important for the analysis of the nature of PD source. Moreover, it could be suggested that any standardized calibration method should be established replacing IEC 60270 as far as any type of non-conventional sensors are concerned.

  • PDF

PSD센서를 이용한 실시간 3차원 위치의 복원 (Restoration of Realtime Three-Dimension Positions Using PSD Sensor)

  • 최훈일;조용준;유영기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.507-510
    • /
    • 2003
  • In this paper, optical sensor system using PSD(Position Sensitive Detection) is proposed to obtain the three dimensional position of moving markers attached to human body. To find the coordinates of an moving marrer with stereo vision system, two different sight rays of an moving marker are required. Usually, those are acquired with two optical sensors synchronized at the same time. PSD sensor is used to measure the position of an incidence light in real-time. To get the three-dimension position of light source on moving markers, a conventional camera calibration method are used. In this research, we realized a low cost motion capture system. The proposed system shows high three-dimension measurement accuracy and fast sampling frequency.

  • PDF

머리전달함수를 이용한 로봇의 화자 위치 추정 (Detection of Speaker Position for Robot Using HRTF)

  • 황성목;박윤식;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.637-640
    • /
    • 2005
  • We propose a sound source localization method using the Head-Related-Transfer-Function (HRTF) to be implemented in a given platform. HRTFs contain not only the information regarding proper time delays but also phase and magnitude distortions due to diffraction and scattering by the shading object. Therefore, a set of HRTFs for any given platform provides a substantial amount of information as to the whereabouts of the source. In this study, we introduce new phase criterion in order to find the sound source location in accordance with the HRTF database empirically obtained in an anechoic chamber with the given platform. Using this criterion, we analyze the estimation performance of the proposed method in a household environment.

  • PDF

가스절연개폐장치의 전위감지 시스템에 대한 연구 (A study on the Potential Detection System of Gas Insulated Switchgear)

  • 최승길;백승국;김광호;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2284-2286
    • /
    • 1999
  • This paper describes the development of potential detection system in 22.9kV gas insulated switchgear. This system composed with main system and LPS can detect the source voltage by capacitive potential division which is accomplished by inserting signal electrode between main electrode and earthed metal enclosure of the switchgear. The appropriate position of signal electrode is achieved by numerical analysis using finite element method. The developed potential detection system is verified by several tests such as voltage test, swc test and others and by applicaion at site. From the results, it is concluded that potential detection system is very reliable and available to operate the switchgear safely.

  • PDF

해저 지형 정보를 이용한 다중 상태 소나의 표적 위치 측정 (Target Localization Using Underwater Objects in Multistatic Sonar)

  • 이광희;서익수;한동석
    • 전자공학회논문지
    • /
    • 제51권2호
    • /
    • pp.141-147
    • /
    • 2014
  • 본 논문에서는 사전에 알고 있는 해저 지형정보를 이용하여 송수신기의 위치와 해저 음속의 정확성을 향상시켜 탐지 범위에 따른 오차에 강인한 위치 측정 알고리듬과 최적의 수신기 개수를 제안하고자 한다. 송수신기 위치, 음속정보의 정확도는 표적 위치 측정의 성능에 영향을 미치며, 송수신기는 GPS를 통해 위치 정보를 얻는다. 그러나 GPS 오차에 의해 여전히 오차를 가지고 있으며, 음속 정보는 수온을 포함한 다양한 요인들에 의해 영향을 받는다. 먼저 송수신기 위치 오차, 음속 오차의 영향을 수학적으로 분석하고 해저 지형 정보를 이용하여 오차를 줄일 수 있는 방법을 확인한다. 컴퓨터 모의실험을 통하여 기존의 알고리듬과 제안된 기법의 성능을 비교 평가하고, 탐지 범위에 따른 최적의 수신기 개수를 확인한다.

도플러 스캐닝 기법을 이용한 이동하는 다중 음원의 상대 위치 추적 기법 (The Relative Position Estimate of the Moving Distributed Sources Using the Doppler Scanning Technique)

  • 노용주;윤종락;전재진
    • 한국음향학회지
    • /
    • 제21권5호
    • /
    • pp.446-454
    • /
    • 2002
  • 본 연구는 이동 표적체에서 주파수가 서로 다른 신호가 서로 다른 위치에서 발생할 때 도플러 주파수 편이량을 추정하여 이들의 상대적인 신호 발생 위치를 추적하는 도플러 스캐닝 기법에 관한 연구이다. 예를 들어 선박의 발전기와 프로펠러 등과 같은 탑재 기계장치들의 진동에 의해 야기되는 기계적 소음의 각 특징 주파수들의 도플러 주파수 편이는 최단근접거리 (CPA: Closest Point of Approach)에 따라 유일한 시간 정보를 갖고 각 소음원들의 위치에 관련되는 함수이다. 따라서 도플러 스캐닝 기법을 적용하면 이동 선박의 각 기계적 소음원들간의 공간적인 상대 위치 추정이 가능하다. 그러나 일반적으로 기계류 소음의 주파수는 저주파수대역이므로 도플러 주파수 편이량을 추정하기 위해서는 주파수 분해능이 높아야 하고 아울러 탑재장치의 공간분해능을 높이기 위해서는 동시에 시간 분해능이 높아야 한다. 따라서 상호 역비례 관계에 있는 이들 분해능을 동시에 높이기 위해 확장 칼만 필터 알고리즘을 적용하여 특징 신호들의 도플러 주파수 편이량을 추정하여 기계류의 상대적인 탑재 위치를 규명할 수 있음을 보인다. 먼저 수치모의 실험으로 그 가능성을 검증하고 자동차에 탑재된 스피커 음원을 사용한 실험 결과를 통해 그 성능을 확인하도록 한다.

Development of an energy and efficiency calibration method for stilbene scintillators

  • Kim, Chanho;Kim, Jaehyo;Hong, Wooseong;Yeom, Jung-Yeol;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3833-3840
    • /
    • 2022
  • A method for calibrating the energy scale and detection efficiency of stilbene scintillators is presented herein. This method can be used to quantitatively analyze the Compton continuum of gamma-ray spectra obtained using such scintillators. First, channel-energy calibration was conducted by fitting a semi-empirical equation for the Compton continuum to the acquired energy spectrum and a new method to evaluate the intrinsic detection efficiency, called intrinsic Compton efficiency, of stilbene scintillators was proposed. The validity of this method was verified by changing experimental conditions such as the number of sources being measured simultaneously and the detector-source distance. According to the energy calibration, the standard error for the estimated Compton edge position was ±1.56 keV. The comparison of the intrinsic Compton efficiencies calculated from the single- and two-source spectra showed that the mean absolute difference and the mean absolute percentage difference are 0.031 %p and 0.557%, respectively, demonstrating reasonable accuracy of this method. The feasibility of the method was confirmed for an energy range of 0.5-1.5 MeV, showing that stilbene scintillators can be used to quantitatively analyze gamma rays in mixed-radiation fields.