• Title/Summary/Keyword: Source of loss

Search Result 1,216, Processing Time 0.029 seconds

Performance Analysis of Chained Amplifier Systems for Metropolitan Optical Network Applications

  • Lee, Jong-Hyung;Choi, Byeong-Yoon
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.377-382
    • /
    • 2009
  • In this paper, theoretical analysis for metropolitan optical networks is performed. First, analytical optical SNR is derived assuming each node consists of an EDFA, an optical filter, an optical switch, and a VOA, and then the relationship between OSNR and BER is studied. In a metropolitan optical network, an optical signal can be dropped to deliver data, and we also studied the effect of drop loss on system performance. When the drop loss is relatively small, the receiver structure of the node can be treated as a preamplifier receiver which is widely used in long-haul systems. In that case, ASE noise from EDFAs is the dominant noise source in the receiver. However, system performance is relatively insensitive to OSNR when the drop loss is significant because of the noise sources in the receiver (thermal and shot noise).

Dependence of Round type electrodeless lamp according to Ferrite shape (페라이트 형상에 따른 둥근형 무전극 램프의 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.465-466
    • /
    • 2007
  • In electrode-less lamp, The key point in creating an efficient light source based on RF discharge is to minimize the RF power loss in the RF coupler which for Anderson's type of RF lamp is due to losses in the ferrite core. This loss depends on the particular ferrite material, its size, geometry, frequency in this kind of inductive lamp shows that the correct choice of discharge current has a crucial effect on the core loss. In this study, we measured Ferrite temperature in normal state, then analyzed electrical and optical characteristics according to ferrite shape. We were able to know that was ferrite of the antenna had relate closely with temperature and luminous of the lamp. Also we appraised temperature and electrical, optical properties during turn on the lamp.

  • PDF

Insertion Loss by Noise Barrier on the Discontinuous Ground (불연속 지면위의 방음벽에 의한 삽입손실에 관한 연구)

  • Kim, Ye-Hyun;Kim, Dong-Ill;Jang, Ho-Kyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.114-121
    • /
    • 1995
  • Outdoor experimental study is presented the insertion loss caused by barrier considering discontinuous ground condition. Measurements ware made in 1/3 octave band over the frequency range 315 Hz~3150 Hz with the various geometry of the source, receiver and barriers. The frequency range of the interference pattern depends on the phase difference between path from the edge of barrier to receiver, and hence on the acoustical properties of the ground on the receiver side of the barrier. The insertion loss by barrier, in addition to diffraction, is shown to be dependent on the ground characteristic.

  • PDF

Prediction of A Rise in Temperature Distribution of Mold Transformer for Power Distribution System (배전용 몰드변압기에 대한 상승 온도 분포 예측)

  • Lee, Jeong-Keun;Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.391-394
    • /
    • 2009
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 2 MVA distribution mold transformer using finite element method (FEM). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage winding and low-voltage winding of mold transformer and Joule's loss of core for improvement these life, forecasted heat source, and high-voltage winding and low-voltage winding of mold transformer and rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the result Also, calculated temperature rise limit of mold transformer and permission maximum temperature using analysis by electron miracle heat source alculate and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

  • PDF

Contribution of production and loss terms of fission products on in-containment activity under severe accident condition for VVER-1000

  • Jafarikia, S.;Feghhi, S.A.H.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.125-137
    • /
    • 2019
  • The purpose of this paper is to study the source term behavior after severe accidents by using a semi-kinetic model for simulation and calculation of in-containment activity. The reactor containment specification and the safety features of the containment under different accident conditions play a great role in evaluating the in-containment activity. Assuming in-vessel and instantaneous release of radioactivity into the containment, the behavior of in-containment isotopic activity is studied for noble gasses (Kr and Xe) and the more volatile elements of iodine, cesium, and aerosols such as Te, Rb and Sr as illustrative examples of source term release under LOCA conditions. The results of the activity removal mechanisms indicates that the impact of volumetric leakage rate for noble gasses is important during the accident, while the influence of deposition on the containment surfaces for cesium, mainly iodine isotopes and aerosol has the largest contribution in removal of activity during evolution of the accident.

Exhaust Noise Reduction of Dry vacuum Pump (건식진공펌프의 배기 소음 저감)

  • Ahn, Young-Chan;Lee, Hae-Jin;Lee, Jung-Yoon;Yang, Jung-Jik;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.349-354
    • /
    • 2007
  • This paper considers acoustic analysis of silencer within a Dry vacuum pump. Main object is noise reduction of Dry Vacuum Pump using the silencer. First, we measured SPL and Intensity for noise source identification and then, designed for the silencer corresponding with noise character. 4-pole parameter are used for predicting transmission loss which is one of characteristics of silencer when we designed for silencer. Calculated Transmission Loss to change main effective factor and selected to optimal value using Design of Experiment. Finally, noise reduction is estimated to compare existing silencer with optimal silencer.

  • PDF

A Novel Compact Metamaterial Zeroth Order Resonant Bandpass Filter for a VHF Band and Its Stopband Improvement by Transmission Zeros

  • Kahng, Sungtek;Jang, Geonho
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.4
    • /
    • pp.263-266
    • /
    • 2013
  • A novel compact and low-loss VHF bandpass filter is presented with enhanced stopband performance using metamaterial zeroth order resonator (ZOR) characteristics. An in-line ZOR filter is initially suggested and changed to have transmission zeros (TZs) due to source-load coupling for effective improvement of the isolation from UHF wireless channels. The proposed filter is smaller than 1/10 of the conventional filters in terms of size and has relatively very low insertion loss (< 1 dB for the electromagnetic (EM) simulation and < 3 dB for the measurement) and return loss (<-20 dB) in the passband due to the approximately 80% size reduction and the higher isolation in the stopband due to the TZs. The circuit and EM simulation are in good agreement with the measurements.

The High Efficiency Operation of Induction Motor by Current Source GTO Inverter with Low Loss Commutation and Snubber Energy (轉流 및 Snubber 에너지 손실을 저감시킨 전류형 GTO 인버터에 의한 유도전동기의 고효율 운전)

  • 최상원;김진표;이종하
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.117-125
    • /
    • 1998
  • In this paper, in order to develop the three phase GTO CSI of high efficiency 1M drive with low loss commutation and snubber energy, we studied the energy recovery circuit to recover stored energy in clamping capacitor and DC link inductor(VCC-l and VCC-2), and snubber capacitor(VCC-3). By using an induction motor as the load of inverter, experimental results show that dissipated DC power is decreased and capacitor voltage Vc is effectively suppressed by VCC-2 and VCC-3 system, and the validity of VCC-3 system with low loss commutation and snubber energy is proofed.roofed.

  • PDF

On the Improved Green Integral Equation applied to the Water-wave Radiation-Diffraction Problem

  • Do-Chun,Hong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 1987
  • It is shown that irregular frequencies in the source and doublet distribution method, can be eliminated if the Green function associated with Kelvin's source of pulsating strength, is modified only in the region inside the body at the level of the undisturbed free surface. The system of the resulting Green integral equation is augmented without loss of the square-integrable property of its kernel so hat the discretisation yield N linearly independent equations for N unknown variables. From the solution, the potential and velocity at any point on the wetted surface of a surface-piercing body can be found using the properties of the double layer composed of the source and normal doublet distribution.

  • PDF

The characteristics of Silent discharge using RF power source (고주파 전원인가에 의한 무성방전 특성에 관한 연구)

  • Lee, Sang-Keun;Lee, Dong-Wook;Chun, Byung-Joon;Song, Hyun-Jig;Lee, Kwang-Sik;Kwon, Hyuk-Han
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.570-572
    • /
    • 2000
  • The characteristics of ozone generation were investigated in accordance with varying the diameter of internal electrode in an ozonizer using RF power source. The characteristics of ozone generation were improved with the diameter of internal electrode increased, but thermal loss was increased. Therefore, it was found that it is inevitable that the cooler has to be installed in an ozonizer which uses RF power source.

  • PDF