• Title/Summary/Keyword: Source Localization

Search Result 381, Processing Time 0.022 seconds

Antigenic localities in the tissued of Metagonimus yokogawai observed by immunogoldlabeling method (면역황금 표식법을 이용한 요꼬가와흡충의 조직내 항원성 부위에 관한 연구)

  • Ahn, Hyuk;Rim, Han-Jong;Kim, Soo-Jin
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.245-258
    • /
    • 1991
  • In order to determine the antigenic localization in the tissues of the adult Metagonimus yokegawai, immunogoldlabeling method was applied using serum immunoglobulins (IgG) of cats which were infected with isolated metacercariae from Plecoglossus altivelis. The sectioned worm tissue was embedded in Lowicryl HM 20 medium and stained with infected serum IgG and protein A gold complex (particle size: 12 nm) , It was observed by electron microscopy at each tissue of the worm. The gold particles were observed on the tegumental syncytium as well as cytoplasm of tegumental cells and epithelial lamella of the caecum. The gold particles were not observed on the basal lamina of the tegument, interstitial matrix of the parenchyma, the muscle tissue and mitochondria of the tegument. The gold particles were specifically labeled in the secretory granules in the vitelline cells. They were also labeled on the lumen of bladder and egg shell. The above findings showed that antigenic materials in the tissue of adult worms were specifically concentrated on the tegumental syncytium as well as cytoplasm of tegumental cells and epithelial lamella of the caecum.

  • PDF

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19-9 (대장직장암 및 기타 소화기암에서의 단세포군항체를 이용한 방사면역신티그라피의 진단)

  • Jang, Dae-Hwan;Choi, Duck-Joo;Lee, Bum-Woo;Park, Won;Han, Chang-Soon;Kim, Hak-San;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.1
    • /
    • pp.83-92
    • /
    • 1988
  • The cocktails of two $^{131}I$ labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F$(ab')_2$ + Anti CEA $F(ab')_2$ fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach(2) and pancreas(1) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100% One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summerized as follows 1) The use of cocktails of CEA and CA 19-9 MCAB $F(at')_2$ increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivitv and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessory when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, $F(ab')_2$ fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

  • PDF

A Study on the Round Clay Rim Pottery Culture in Kangwon Region (강원지역의 점토대토기문화 고찰)

  • Lee, Suk-Im
    • KOMUNHWA
    • /
    • no.69
    • /
    • pp.63-89
    • /
    • 2007
  • The Archaeological sites of so called Round Clay Rim Pottery (Jeomtodaetogi : 점토대토기) culture in Kangwon region have been rarely excavated in proper form. Since most cases belong to those of ground surface gatherings, it is difficult to certify the nature and the association with other artifacts. Therefore, researches on that culture have been limited to simply set the chronological order in the Bronze Age in realtion with the Plain Pottery culture. However, a comparative study trying to explain the Round Clay Rim Pottery culture in both Yeongseo(영서) and Yeongdong(영동) has become possible thanks to recent excavation results from the sites of Chilgeon-dong(칠전동) in Chunchon City(춘천시) and Songrim-ri(송림리) in Kangneung City(강릉시), for example. Certain difference can be observed in form and amount of artifacts in between Yeongseo and Yeongdong. Such difference can be seen as individual localization in different places diffused from a common source, rather than showing different stages of unilineal developmental process of one culture. The Round Clay Rim Pottery culture seems to have been coexisted with the Rim-Perforated Pottery(공렬토기) and Dolmen(지석묘) culture. According to the radiocarbondatings, the upper time limit of the Round Clay Rim Pottery culture goes back considerably beyond the alleged upper limit of either the late fourth century or the second century B.C.. However, both cultures absorbed into the Iron Culture during the same period.

  • PDF

The Effect of Autophagy to Cell Death in Nutrient-Deprived H460 Cells (영양분이 결핍된 H460 세포주에서 자가포식이 세포사멸에 미치는 영향)

  • Jang, Hye-Yeon;Jo, Hyang-Jeong;Hwhang, Ki-Eun;Kim, So-Young;Lee, Kang-Kyoo;Moon, Sun-Rock;Shin, Jeong-Hyun;Cho, Kyung-Hwa;Lee, Mi-Kung;Lee, Sam-Youn;Park, Soon-Ah;Park, Jong-Kun;Kim, Hui-Jung;Yang, Sei-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.2
    • /
    • pp.81-94
    • /
    • 2010
  • Background: Autophagy is an important adaptive mechanism in normal development and in response to changing environmental stimuli in cancer. Previous papers have reported that different types of cancer underwent autophagy to obtain amino acids as energy source of dying cells in nutrient-deprived conditions. However, whether or not autophagy in the process of lung cancer causes death or survival is controversial. Therefore in this study, we investigated whether nutrient deprivation induces autophagy in human H460 lung cancer cells. Methods: H460, lung cancer cells were incubated in RPMI 1640 medium, and the starved media, which are BME and RPMI media without serum, including 2-deoxyl-D-glucose according to time dependence. To evaluate the viability and find out the mechanism of cell death under nutrient-deprived conditions, the MTT assay and flow cytometry were done and analyzed the apoptotic and autophagic related proteins. It is also measured the development of acidic vascular organelles by acridine orange. Results: The nutrient-deprived cancer cell is relatively sensitive to cell death rather than normal nutrition. Massive cytoplasmic vacuolization was seen under nutrient-deprived conditions. Autophagic vacuoles were visible at approximately 12 h and as time ran out, vacuoles became larger and denser with the increasing number of vacuoles. In addition, the proportion of acridine orange stain-positive cells increased according to time dependence. Localization of GFP-LC3 in cytoplasm and expression of LC-3II and Beclin 1 were increased according to time dependence on nutrient-deprived cells. Conclusion: Nutrient deprivation induces cell death through autophagy in H460 lung cancer cells.

Leakage noise detection using a multi-channel sensor module based on acoustic intensity (음향 인텐시티 기반 다채널 센서 모듈을 이용한 배관 누설 소음 탐지)

  • Hyeonbin Ryoo;Jung-Han Woo;Yun-Ho Seo;Sang-Ryul Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.414-421
    • /
    • 2024
  • In this paper, we design and verify a system that can detect piping leakage noise in an environment with significant reverberation and reflection using a multi-channel acoustic sensor module as a technology to prevent major plant accidents caused by leakage. Four-channel microphones arranged in a tetrahedron are designed as a single sensor module to measure three-dimensional sound intensity vectors. In an environment with large effects of reverberation and reflection, the measurement error of each sensor module increases on average, so after placing multiple sensor modules in the field, measurement results showing locations with large errors due to effects such as reflection are excluded. Using the intersection between three-dimensional vectors obtained from several pairs of sensor modules, the coordinates where the sound source is located are estimated, and outliers (e.g., positions estimated to be outside the site, positions estimated to be far from the average position) are detected and excluded among the points. For achieving aforementioned goal, an excluding algorithm by deciding the outliers among the estimated positions was proposed. By visualizing the estimated location coordinates of the leakage sound on the site drawing within 1 second, we construct and verify a system that can detect the location of the leakage sound in real time and enable immediate response. This study is expected to contribute to improving accident response capabilities and ensuring safety in large plants.

Benchmark Test Study of Localized Digital Streamer System (국산화 디지털 스트리머 시스템의 벤치마크 테스트 연구)

  • Jungkyun Shin;Jiho Ha;Gabseok Seo;Young-Jun Kim;Nyeonkeon Kang;Jounggyu Choi;Dongwoo Cho;Hanhui Lee;Seong-Pil Kim
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.2
    • /
    • pp.52-61
    • /
    • 2023
  • The use of ultra-high-resolution (UHR) seismic surveys to preceisly characterize coastal and shallow structures have increased recently. UHR surveys derive a spatial resolution of 3.125 m using a high-frequency source (80 Hz to 1 kHz). A digital streamer system is an essential module for acquiring high-quality UHR seismic data. Localization studies have focused on reducing purchase costs and decreasing maintenance periods. Basic performance verification and application tests of the developed streamer have been successfully carried out; however, a comparative analysis with the existing benchmark model was not conducted. In this study, we characterized data obtained by using a developed streamer and a benchmark model simultaneously. Tamhae 2 and auxiliary equipment of the Korea Institute of Geoscience and Mineral Resources were used to acquire 2D seismic data, which were analyzed from different perspectives. The data obtained using the developed streamer differed in sensitivity from that obtained using benchmark model by frequency band.However, both type of data had a very high level of similarity in the range corresponding to the central frequency band of the seismic source. However, in the low frequency band below 60 Hz, data obtained using the developed streamer showed a lower signal-to-noise ratio than that obtained using the benchmark model.This lower ratio can hinder the quality in data acquisition using low-frequency sound sources such as cluster air guns. Three causes for this difference were, and streamers developed in future will attempt to reflect on these improvements.

The Lung Expression of Proinflammatory Cytokines, TNF-$\alpha$ and Interleukin 6, in Early Periods of Endotoxemia (내독소혈증 유발 급성폐손상에서 폐장내 Proinflammatory Cytokines 발현에 관한 고찰)

  • Moon, Seung-Hyug;Kim, Yong-Hoon;Park, Choon-Sik;Lee, Shin-Je
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.3
    • /
    • pp.553-564
    • /
    • 1998
  • Background: The immediate hoot response to LPS is the production of proinflammatory cytokines that act as intercellular mediators in inflammatory reactions, including acute lung injury. These "early response" cytokines transmit signals from recognition cells to target or effector cells. This host response is further amplified by the expression of leukocyte chemoattractants, growth factors, and adhesion molecules, resulting in an array of proinflammatory events. This experiment was performed to define the lung origin of proinflammatory cytokines, such as TNF-$\alpha$, IL 6 in early periods of endotoxin induced acute lung injury (ALI). Method: The healthy male Sprague-Dawley, weighted 150 - 250g, were divided into saline control (NC) and endotoxemia-induced ALI (ETX-), and leukopenic endotoxemia-induced ALI (CPA-ETX-Group) which was induced by cyclophosphamide, 70 mg/kg i.p. injection. Acute lung injury was evoked by LPS, 5 mg/kg, intravenously administered. Bronchoalveolar lavage was performed at 0, 3, 6 h after LPS-treated to estimate the influx of phagocytes and concentration of total protein, and cytokines as TNF-$\alpha$ and IL 6 by a bioassy using MIT method. We also examined the localization of TNF-$\alpha$ and IL 6 protein in endotoxemia-challenged lung tissue by immunohistochemical stain (IH). Results: The total cell, macrophage and PMN count in BALF were elavated in ETX group compared to NC(p<0.05). In CPA-ETX group, total cell and macrophage count in BALF were not changed compared to NC. but PMN count was markedly reduced and it took part in less than 0.1 % of total BAL cells (p<0.01). The protein concentration in BALF were significantly increased in ETX and CPA-ETX group Compared to NC (p<0.05), but there was significant difference between ETX- and CPA-ETX group only at 6 h (p<0.05). This observation suggested that even if PMNs are involved in the pathogenesis of acute lung injury, their role cannot be viewed as essential The concentration of TNF-$\alpha$ and IL 6 in BALF was significantly increased in the ETX- and CPA-ETX group compared to NC. There was no difference between ETX- and CPA-ETX group. In IH, anti-TNF-$\alpha$- and anti-IL 6 antibody was strongly localized at interstitial monocytes and alveolar macrophages in endotoxemia-challenged lung tissue. From above point of view, activated alveolar macrophage/monocyte considered as a prominent source of proinflammatory cytokines in endotoxemia-challenged lung injury. Conclusion: The prominent source of proinflammatory cytokines in early periods of endotoxemia-induced lung injury will be the activated resident macrophages like an alveolar macrophage and interstitial monocytes. The pulmonary macrophage/monocyte will impact the initiation and continuance of lung injury without PMNs's certain inflammatory role, particularly in endotoxemia-induced acute lung injury.

  • PDF

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF