• 제목/요약/키워드: Source Generator

검색결과 560건 처리시간 0.03초

디지탈 신호처리기를 이용한 원자로 증기발생기 검사용 실시간 비젼시스템 개발 (Real Time Vision System for the Test of Steam Generator in Nuclear Power Plants Using Digital Signal Processors)

  • 왕한흥;한성현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.469-473
    • /
    • 1996
  • In this paper, it is proposed a new approach to the development of the automatic vision system to e famine and repair the steam generator tubes at remote distance. In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. Digital signal processors are used it, implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF

System Analysis of a Gas Generator Cycle Rocket Engine

  • Cho, Won Kook;Kim, Chun IL
    • International Journal of Aerospace System Engineering
    • /
    • 제6권2호
    • /
    • pp.11-16
    • /
    • 2019
  • A system analysis program has been developed for a gas generator cycle liquid rocket engine of 30 ton class. Numerical models have been proposed for a combustor, a turbopump, a gas generator and pressure drop through a regenerative cooling system. Numerical algorithm has been validated by comparing with the published data of MC-1. The major source of error is not the numerical algorithm but the imperfect performance models of subsystems. So the precision of the program can be improved by revising the performance models using experimental data. The sea level specific impulse and vacuum specific impulse have been demonstrated for a 30 ton class gas generator engine. The optimal condition of combustor pressure and mixture ratio for specific impulse which is a typical characteristic of a gas generator cycle engine has been illustrated.

발전기 통합제어장치 개발 (A Development of Unified Digital Generator Controller)

  • 유영석;권혁;이상정;이선희;최용실
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1164-1166
    • /
    • 1996
  • This system is an unified Digital Generator Controller. It has an Electronical Generator Sequencer which control the sequence of a generator, an AVR(Automatic Voltage Regulator) which perform the regulation of generator terminal voltage optimally to user's needs, and an Auto Synchronizer, it can switch the power source on from generally used an the generator to load automatically. It also possesses a Battery Charger which charge a storage battery to appropriate voltage level. Here we describe it's configuration, specifications, the way of control, figure, functions and waveforms.

  • PDF

이동용 발전기의 접지방식에 관한 연구 (A Study on the Scheme of Ground Connection for the Mobile Generator)

  • 조규덕;김봉태;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.81-84
    • /
    • 2001
  • In industrial field, especially the mobile generator is almost used as a islanding generator source for light, electric thrill, and compressor, and so on. However, because there still exists a lot of aged load, it causes the electric shock against person. In this paper authors introduce the proper method to reduce the electric shock in field discussing the scheme of ground connection.

  • PDF

DSP-Based Direct Source Current Control for Three-Phase Four-Wire Power Coditioner

  • Jeong, C.Y.;Cho, J.G.;Baek, J.W.;Yoo, D.W.;Song, E.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.871-875
    • /
    • 1998
  • A DSP-based source current control for power conditioner is presented to compensate current harmonics and asymmetries of three-phase four-wire emergency generators caused by nonlinear and/or unbalanced loads. There-phase voltage type converter with split-dc-capacitor is adopted as the power circuit and a new direct source current control method is suggested, which simplifies the controller. The proposed control method shapes the generator current sinusoidally inphase with the voltage and allows the generator to supply maximum power even to single phase loads. An IGBT base lookVA prototype with the controller realized with a DSP (TMS320C32) is built and tested to verify the performance of the power conditioner.

  • PDF

순시전원제어에 의한 수산화가스 발생장치에 관한 연구 (A Study on Brown Gas Generator with Instantaneous Source Power Control)

  • 전윤석;이상용;목형수;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1093-1095
    • /
    • 2003
  • The mixed gas of Hydrogen and Oxygen has obtained from water electrolysis reaction. It has constant volume ratio 2 : 1 Hydrogen and Oxygen, and it is used as a source of thermal energy by combustion reaction. In this paper, Brown Gas Generator with Instantaneous source power control method is designed and relationship between brown gas quantities, efficiency and power condition is studied.

  • PDF

튜브형 고분자전해질 연료전지와 일회용 수소발생소자를 결합한 미세유체소자용 전원공급소자 (Disposable Power Generator with Tubular PEMFC and H2 Generator for the Power Source of Microfluidic Devices)

  • 김광호;서영호;김병희
    • 대한기계학회논문집A
    • /
    • 제34권7호
    • /
    • pp.829-835
    • /
    • 2010
  • 본 연구에서는 미세유체소자의 전원소자로 적용하기 위한 일회용 수소발생소자와 튜브형 고분자전해질 연료전지로 구성된 일회용 전원소자에 관한 것이다. 튜브형 고분자전해질 연료전지는 1.52 mm의 직경을 가지며, 수소발생소자는 알루미늄과 5M 수산화나트륨의 반응을 통해 수소를 발생시켜 튜브형 고분자전해질 연료전지로 공급하게 된다. 단위 튜브형 고분자전해질 연료전지는 순수한 수소에 대해여 0.81V 의 개방전압과 0.35V에서 $16.4\;mW/cm^2$의 최대전력밀도를 나타내었으며, 수소발생기는 15 분 동안 $11.6\;m{\ell}$의 수소를 생성하였다. 튜브형 고분자전해질 연료전지와 수소발생기가 결합된 일회용 전원소자는 아무런 주변장치 없이 10 분 동안 1.06 mW (0.46V)의 일정한 전력을 발생하였으며, 3 개가 직렬로 연결된 고분자전해질 연료전지는 10 분 동안 LED(2.5 mW@1.8V)를 동작시켰다.

LCL 필터의 성능 검증을 위한 SPWM 제어기반의 3상 인버터 출력 파형 발생 장치 개발 및 적용 연구 (Development And Application of Three-phase Inverter Output Wave Generator based on SPWM Control to Verify the Performance of LCL filters)

  • 임동균;강창균;하원진;촐롱바타르;고윤석
    • 한국전자통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.841-852
    • /
    • 2022
  • 본 논문에서는 LCL 필터의 성능 검증을 위한 SPWM 제어기반의 3상 인버터 출력 파형 발생 장치를 개발하였다. 필터의 성능 검증을 위한 검사 신호를 얻기 위해 먼저, DSP 기반의 3상 SPWM 신호 생성 알고리즘을 개발하였으며, 동시에 3개의 하프 브리지 게이트 드라이버를 이용하여 SPWM 게이트 구동 신호들로부터 3상 SPWM 출력 파형을 발생시키기 위한 3상 전압형 인버터 회로를 설계하였다. 다음, 개발된 SPWM 기반 3상 인버터 출력 파형 장치의 검사 신호 발생 장치로서의 유효성을 검증하기 위해 하나의 LCL 필터가 실험, 제작되었으며, DSP 기반의 성능 검증 시스템이 실험적으로 구축되었다. 끝으로, 주어진 시비율을 가지는 출력 제어 실험에서 LCL 필터의 전 후의 3상 전압 파형을 비교함으로써 SPWM 기반 3상 인버터 출력파형 발생 장치의 유효성을 확인할 수 있었다.

발전기 무효전력 성능시험 절차 개발 (Development of Generator Reactive Capability Test Method in Generation Stations)

  • 신만수;정태원
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.936-941
    • /
    • 2011
  • Generation cooperations have focused on active power directly related to economic value. So, utility cooperation have taken expense to stabilize power system, although generator has responded quickly with variation of power system voltage and is controlled at real time. As a reactive power source, it is necessary for generator's capabilities to be verified. But domestic generators scarcely have been tested and operated to reactive power capability. In case of power system fault, operators would not quickly take a follow-up actions about reactive power disturbance. Therefore generator reactive power capability verification strategy must be developed, several generators is tested as examples since 2004. This paper is extracted from the test results.

하드웨어 잡음발생기의 랜덤 특성 분석 (Analysis of Randomness Characteristics of Hardware Noise Generator)

  • 홍진근
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.263-267
    • /
    • 2011
  • 본 논문은 하드웨어 잡음원 기반으로 하는 발생기에서 출력되는 정보의 랜덤성 특성을 분석하였다. 또한 발생기 출력열에 라플라시안 필터를 적용하여 보안성을 개선하였다. 먼저 하드웨어 잡음 발생기 출력열의 랜덤성 검증기준을 살펴보고, 라플라시안 필터가 적용된 발생기의 출력열 개선 결과를 제시하였다.