• 제목/요약/키워드: Sound pressure Level

검색결과 690건 처리시간 0.027초

가청 주파수대 음장 변화 측정 기반 침입 감지 기술 (Intrusion Detection Based on the Sound Field Variation of Audible Frequency Band)

  • 이성규;박강호;양우석;김종대;김대성;김기현;왕세명
    • 한국소음진동공학회논문집
    • /
    • 제21권3호
    • /
    • pp.212-219
    • /
    • 2011
  • In this paper, intrusion detection technique based on the sound field variation of audio frequency in the security space is proposed. The sound field formed by sound source can be detected with the microphone when the obstacle or intruder is positioned. The sound field variation due to the intruder is mainly caused by the interference of audio wave. With the help of numerical simulation of sound field formations, the increase or decrease of sound pressure level is analyzed not only by the obstacle, but also by the intruder. Even the microphone is positioned behind the source, sound pressure level can be increased or decreased due to the interference of sound wave. Frequency response test is performed with Gaussian white noise signal to get the whole frequency response from 0 to half of sampling frequency. There are three security cases. Case 1 is the situation of empty space with and without intruder, case 2 is the situation of blocking obstacle with and without intruder, and case 3 is the situation of side blocking obstacle with and without intruder. At each case, the frequency response is obtained first at the security space without intruder, and second with intruder. From the experiment, intruder size of diameter of 50 cm pillar can be successfully detected with the proposed technique. Moreover, the case 2 and case 3 bring about bigger sound field variation. It means that the proposed technique have the potential of more credible security guarantee in real situation.

표준시험동 바닥충격음 측정위치에 대한 고찰 (Investigation of receiving position in the measurement method for floor impact sound in a testing building)

  • 이신영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

Binaural Recording 기법을 이용한 다양한 철도차량의 Pass-by 소음의 성가심 분석 (Analysis of Annoyance of Various Train Pass-by Noise Using Binaural Recording)

  • 박범;고효인;박준홍
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.289-298
    • /
    • 2014
  • Pass-by noises of various trains were recorded by binaural recorder. The measured noises were evaluated using a sound pressure level and psychoacoustic metrics objectively. To analyze a binaural effect on annoyance that can be caused by train noise, auditory experiments were performed. Through the experiments, the annoyance differences between monaural and binaural train noises, the annoyance differences due to measurement angle and the annoyance differences due to kinds of train and measurement distance were determined. A correlation analysis was conducted to determine which index can affect the annoyance more strongly. As the result, a maximum rate of change of sharpness difference between left and right channels was proposed to predict the annoyance.

슬림형 룸에어컨 설계 인자에 관한 연구 (Numerical and Experimental Analysis of Design Parameters of a Slim Room Air-conditioner)

  • 신종진;이희술;김종문;민준기;오상경
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.95-100
    • /
    • 2005
  • Numerical simulations and experiments were conducted to analyze the design parameters for a slim room air-conditioner. These design parameters included a fan shape, a front panel, a scroll shape, a bell mouth, a distance between a fan and a heat exchanger, etc. Each design parameter was analyzed numerically and/or experimentally in terms of the flow rate and the sound pressure level, which should be the most influential factors for developing the slim room air-conditioner. The fan with a uniform height showed a better performance than that with a linearly varying height. It is recommended to use a front grill rather than a front panel according to sound pressure levels since the front panel itself is a huge resistance to the inlet flow. A redesigned scroll shape by changing the rotational direction of a fan also contributed a lot to lowering the sound pressure level. There existed a distance between a fan and a heat exchanger, where flow rates increased effectively.

하드디스크 드라이브에서의 소음 저감에 관한 연구 (A Study of Noise Reduction in Hard Disk Drive)

  • 곽주영;손진승;이행수;홍민표;고정석;조은형;좌성훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.579-585
    • /
    • 2001
  • This paper proposed a method of reducing a noise in hard disk drive. This method is performed through three parts of procedures. First procedure is sound-oriented experiment, which contains sound intensity techniques and measurements of sound pressure level and sound power. Second is vibration-oriented experiment, which contains FRF(Frequency Response Function) analysis and disk vibration reduction techniques. And the third is computer-oriented simulation, which contains modal analysis and force vibration analysis using ANSYS and sound radiation prediction using SYSNOISE. As these three parts can affect with each other, they should be considered and conducted simultaneously. Through this procedure sound power is measured 2.7 Bels in idle-spinning mode, which is the lowest noise level in the HDD industries.

  • PDF

원추형 오리피스의 유출계수와 캐비테이션에 관한 실험적 연구 (Experimental study on the discharge coefficients and cavitation of conical orifices)

  • 김병찬;윤병옥;박복춘;조남오;지대성;정백순;박경암
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1371-1379
    • /
    • 1997
  • The high pressure drop is frequently required in the by-pass line of the pump or of the heat exchanger in power plants. However, cavitation produced by a high pressure drop could damage the pipe and pump blades. Conical orifices are adopted to reduce cavitation due to high pressure drop. The discharge coefficients of conical orifice plates were measured by weighing method in the standard water flow system. The discharge coefficients were larger when the ratios of thickness of orifice edge to throat diameter were larger. The noise generated from a conical orifice due to cavitation was measured with a sound level meter and a hydrophone. With increasing the bore diameter of the orifice, the sound pressure level or the noise level due to cavitation became higher. The noise level was suddenly increased at the inception of cavitation.

가청 주파수대 음장 변화 측정 기반 침입 감지 기술 (Intrusion detection based on the sound field variation of audible frequency band)

  • 이성규;박강호;양우석;김종대;김대성;김기현;왕세명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.187-192
    • /
    • 2010
  • In this paper, intrusion detection technique based on the sound field variation of audio frequency in the security space is proposed. The sound field formed by sound source can be detected with the microphone when the obstacle or intruder is positioned. The sound field variation due to the intruder is based on the interference of audio wave. With the help of numerical simulation of sound field formations, the increase or decrease of sound pressure level is analyzed not only the obstacle, but also the intruder. Even the microphone is positioned behind the source, sound pressure level can be increase or decrease due to the interference. Frequency response test is performed with Gaussian white noise signal to get the whole frequency response from 0 to half of sampling frequency. There are three security cases. Case 1 is the situation of empty space with and without intruder, case 2 is the situation of blocking obstacle with and without intruder, and case 3 is the situation of side blocking obstacle with and without intruder. At each case, the frequency response is obtained first at the security space without intruder, and second with intruder. From the experiment, intruder size of $50cm{\times}50cm$ can be successfully detected with the proposed technique. Moreover, the case 2 or case 3 bring about bigger sound field variation. It means that the proposed technique have the potential of more credible security sensing in real situation.

  • PDF

확장형 칼만필터 알고리즘을 활용한 차량 주행에 따른 마찰소음의 총 음압레벨 예측 (Estimation of Total Sound Pressure Level for Friction Noise Regarding a Driving Vehicle using the Extended Kalman Filter Algorithm)

  • 김도완;한범수;문성호;안덕순
    • 한국도로학회논문집
    • /
    • 제16권5호
    • /
    • pp.59-66
    • /
    • 2014
  • PURPOSES : This study is to predict the Sound Pressure Level(SPL) obtained from the Noble Close ProXimity(NCPX) method by using the Extended Kalman Filter Algorithm employing the taylor series and Linear Regression Analysis based on the least square method. The objective of utilizing EKF Algorithm is to consider stochastically the effect of error because the Regression analysis is not the method for the statical approach. METHODS : For measuring the friction noise between the surface and vehicle's tire, NCPX method was used. With NCPX method, SPL can be obtained using the frequency analysis such as Discrete Fourier Transform(DFT), Fast Fourier Transform(FFT) and Constant Percentage Bandwidth(CPB) Analysis. In this research, CPB analysis was only conducted for deriving A-weighted SPL from the sound power level in terms of frequencies. EKF Algorithm and Regression analysis were performed for estimating the SPL regarding the vehicle velocities. RESULTS : The study has shown that the results related to the coefficient of determination and RMSE from EKF Algorithm have been improved by comparing to Regression analysis. CONCLUSIONS : The more the vehicle is fast, the more the SPL must be high. But in the results of EKF Algorithm, SPLs are irregular. The reason of that is the EKF algorithm can be reflected by the error covariance from the measurements.

액슬 와인 음질에 대한 연구 (Sound Quality Analysis for Axle-Gear Whine Sound)

  • 김태규;이상권;조윤경;김종연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.141-146
    • /
    • 2007
  • A gear whine sound due to the axle system is one of the most important sound qualities in a sport utility vehicle (SUV). In the previous research about the gear whine sound, it was known that it is difficult to evaluate the gear whine sound objectively by using the only A-weighted sound pressure level because of the masking effect. In this paper, for the objective evaluation of the axle-gear whine sound, the characteristics of the axle-gear whine sound is at the first investigated based on the synthetic sound technology and the new objective evaluation method for the axle-gear whine sound is developed by using the sound metrics, which is the psychoacoustics parameters, and the artificial neural network (ANN) used for the modeling of the correlation between objective evaluation and subjective evaluation.

  • PDF

전동차용 모터 냉각홴의 공력성능 향상 및 소음특성 (Aerodynamic Performance Enhancement and Noise of Cooling Fans for Driving Motor)

  • 강신형;박태춘;조남효
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.32-40
    • /
    • 1998
  • Aerodynamic performance of a cooling fan of driving motor was enhanced modifying the vane-shroud configuration. Performance of a target model was evaluated to obtain baseline data. The aerodynamic performance and sound pressure level were tested and measured with different numbers of vane of increased length. The tested models show high and stable performance and low values of specific noise level. The long vane-shroud structure induces more stable through flow and decreases the tip leakage flow, which contributes to the increases of performance and efficiency. The sound pressure level increases for the modified model, however, specific noise level decreases.

  • PDF