Abstract

Numerical simulations and experiments were conducted to analyze the design parameters for a slim room air-conditioner. These design parameters included a fan shape, a front panel, a scroll shape, a bell mouth, a distance between a fan and a heat exchanger, etc. Each design parameter was analyzed numerically and/or experimentally in terms of the flow rate and the sound pressure level, which should be the most influential factors for developing the slim room air-conditioner. The fan with a uniform height showed a better performance than that with a linearly varying height. It is recommended to use a front grill rather than a front panel according to sound pressure levels since the front panel itself is a huge resistance to the inlet flow. A redesigned scroll shape by changing the rotational direction of a fan also contributed a lot to lowering the sound pressure level. There existed a distance between a fan and a heat exchanger, where flow rates increased effectively.

Keywords

References

  1. Cho, H. M., Chee, S. K., Park, S. K., and Oh, S. K., 2003, Effects of the discharge system of the standing type air-conditioner on the flow pattern and temperature distribution, Proceedings of the SAREK 2003 Summer Annual Conference, pp. 657-662
  2. Fluent Inc., 2003, Fluent 6.1 User's Guide, Fluent Inc
  3. ASHRAE, 1997, 1997 ASHRAE Fundamentals Handbook: Sound and Vibration, ASHRAE, pp. 7.1-7.10
  4. Bleier, F. P., 1998, Fan Handbook: Selection, Application, and Design, McGraw-Hill, New York