• 제목/요약/키워드: Sound levels

검색결과 520건 처리시간 0.027초

표준시험동 바닥충격음 측정위치에 대한 고찰 (Investigation of receiving position in the measurement method for floor impact sound in a testing building)

  • 이신영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

천장형 에어컨 소음의 허용 음압레벨 도출 (Allowable sound pressure levels of ceiling mounted air-conditioning sounds)

  • 유진;정충일;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

함수율과 밀도가 참오동나무재의 음향 특성에 미치는 영향 (Effect of Moisture Contents and Density of Paulownia tomentosa on Acoustical Properties)

  • 유태경;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권2호
    • /
    • pp.61-66
    • /
    • 1997
  • Paulownia wood has been used as sound board for Korean traditional musical instruments such as Keomungo(Korean lute), Kayagum(twelve-stringed Korean harp) and Changgu(hour-glass shaped drum), etc. The acoustic properties of wood affected not only by dimensions but also by density and stiffness of wood. Due to inhomogeneity and hygroscopicity of wood. the acoustic properties of wood are inconsistent. To clarify the effect of moisture content and air dry density on acoustic properties, longitudinal vibration experiment was accomplished in 3 moisture content levels of 9.6, 11.1 and 12.5% and in 3 air dry density levels of 0.22, 0.25 and 0.28g/$cm^3$. The results were as follows: As the moisture content increased, the fundamental frequency. specific dynamic Young's modulus and sound velocity decreased, but the internal friction increased so that loss of energy increased. The values in damping of sound radiation were rapidly decreased at 12.5%. It meant that the damping of internal friction was larger than damping of sound radiation at high moisture content. As the air dry density increased, the fundamental frequency, specific dynamic Young's modulus and sound velocity increased, but the internal friction and damping of sound radiation decreased so that loss of energy decreased. And acoustic converting efficiency was hardly influenced by increasing air drying density.

  • PDF

소음수준에 따른 신체자세동요의 변화 (Sound Levels and Postural Body Sway during Standing)

  • 박성하;이승원
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.1-15
    • /
    • 2006
  • Loss of postural balance can possibly lead to increased risk of slips and falls in work places. Present study was performed to investigate the effects of noisy environments on postural stability during standing. It is known that a sound is characterized by the frequency and pressure level of the sound. Therefore, effects of the frequency and pressure level on postural stability were of primary concern. Ten male subjects participated in the experiment. Subject's center of pressure(COP) position was collected on a force plate while they were exposed to different frequency and pressure levels of the sound. Measured COP was then converted into the length of postural sway path in both anterior-posterior(AP) and medio-lateral(ML) axis. Results showed that the length of sway path in AP axis was significantly affected by the frequency of sound. The length of sway path was lowest at frequency level of 2000Hz and increased below and above this frequency range. The sound pressure level, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that industrial workers in noisy environments should be aware that their abilities of postural balance can be disturbed significantly.

NCPX를 이용한 도로 표층 유형별 노면 소음 비교 연구 (A Study for Comparing Road Noise by Surface Types using NCPX)

  • 강원평;문학룡
    • 한국도로학회논문집
    • /
    • 제15권6호
    • /
    • pp.61-68
    • /
    • 2013
  • PURPOSES : The purpose of this study is to study the noise reducing effect of Micro Surfacing by comparing general asphalt, longitudinal tining and Slurry Seal. METHODS : This study measures vehicles' noise of each section by the NCPX method that can measure noise between the road surface and the tire at the field. Total sound pressure and sound pressure level by the 1/3 octave band frequency are calculated through the field data of each section. Total sound pressure level is compared by ANOVA test statistically. After ANOVA test, post-hoc test is conducted to know mean difference of surface type by Tukey. RESULTS : As the result of CPB analysis to confirm sound pressure levels by frequency, it was shown that sound pressure levels by frequency are totally similar except for those of frequency bands between 100Hz and 500Hz. The result of ANOVA test and post-hoc test, it was shown that sections of surface type have a difference. The result of Micro Surfacing was lower 2~5dB(A) than other surface type. CONCLUSIONS : It is found that the noise reduction performance of Micro Surfacing was better than other surface type.

도로교통소음의 주파수에 따른 불쾌도 민감도 연구 (Study of the Annoyance Sensitivity for the Frequency Band of Road Traffic Noise)

  • 조경숙;황대선;조연;허덕재
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.398-404
    • /
    • 2007
  • In this study, the sensitivity of annoyance was investigated by the subjective jury test for the variations of the frequency components along with various sound pressure levels of sixteen environmental noise sources. Annoyance was, also, evaluated for the road traffic noises. Sound pressure levels were $54{\sim}84\;dB$ which individually divided frequency components with eight bands of equally three bark bands. The results show that vehicle traffic noise is recognized as the most serious environment noise source. The sensitivity of human perception of annoyance in frequency bands is quite different from A-weighting curve. The annoyance found out to be more sensitive in high frequency region and reached its maximum in 3.4 kHz.

적응형 파라미터 알고리즘을 이용한 개별 소음원의 음향파워 예측 연구 (Parameter-setting-free algorithm to determine the individual sound power levels of noise sources)

  • 문성호
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.59-64
    • /
    • 2018
  • PURPOSES : We propose a parameter-setting-free harmony-search (PSF-HS) algorithm to determine the individual sound power levels of noise sources in the cases of industrial or road noise environment. METHODS :In terms of using methods, we use PSF-HS algorithm because the optimization parameters cannot be fixed through finding the global minimum. RESULTS:We found that the main advantage of the PSF-HS heuristic algorithm is its ability to find the best global solution of individual sound power levels through a nonlinear complex function, even though the parameters of the original harmony-search (HS) algorithm are not fixed. In an industrial and road environment, high noise exposure is harmful, and can cause nonauditory effects that endanger worker and passenger safety. This study proposes the PSF-HS algorithm for determining the PWL of an individual machine (or vehicle), which is a useful technique for industrial (or road) engineers to identify the dominant noise source in the workplace (or road field testing case). CONCLUSIONS : This study focuses on providing an efficient method to determine sound power levels (PWLs) and the dominant noise source while multiple machines (or vehicles) are operating, for comparison with the results of previous research. This paper can extend the state-of-the-art in a heuristic search algorithm to determine the individual PWLs of machines as well as loud machines (or vehicles), based on the parameter-setting-free harmony-search (PSF-HS) algorithm. This algorithm can be applied into determining the dominant noise sources of several vehicles in the cases of road cross sections and congested housing complex.

자동차 BSR 소음특성과 음질 인덱스 개발 (Development of Sound Quality Index with Characterization of BSR Noise in a Vehicle)

  • 신수현;김덕환;정철웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.447-452
    • /
    • 2012
  • Among the various elements affecting a customer's evaluation of automobile quality, buzz, squeak and rattle (BSR) are considered to be major factors. In most vehicle manufacturers, the BSR problems are solved by find-fix method with the vehicle road test, mainly due to various excitation sources, complex generation mechanism and subjective response. The aim of this paper is to develop the integrated experimental method to systematically tackle the BSR problems in early stage of the vehicle development cycle by resolving these difficulties. To achieve this aim, the developed experimental method ought to include the following requirements: to find and fix the BSR problem for modules instead of a full vehicle in order to tackle the problem in the early stage of the vehicle development cycle; to develop the exciter system including the zig and road-input-signal reproducing algorithm; to automatically localize the source region of BSR; to develop sound quality index that can be used to assess the subjective responses to BSR. Also, the BSR sound quality indexes based on the Zwicker's sound quality parameters using a multiple regression analysis. The four sound metrics from Zwicker's sound quality parameter are computed for the signals recorded for eight BSR noise source regions localized by using the acoustic-field visualized results. Then, the jury test of BSR noise are performed for participants. On a basis of the computed sound metrics and jury test result, sound quality index is developed to represent the harsh of BSR noise. It is expected that the developed BSR detection system and sound quality indexes can be used to reduce the automotive interior BSR noise in terms of subjective levels as well as objective levels.

  • PDF

흡음덕트 부착 열회수형 환기장치의 음향성능 평가에 관한 연구 (A study on the acoustic performance evaluation of heat recovery ventilator with a sound absorbing duct)

  • 배명환;송준영;박희성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.468-475
    • /
    • 2016
  • 본 연구에서는 기존 열회수형 환기장치의 음향 문제점을 파악하고, 흡음덕트 설치위치별 열회수형 환기장치의 소음저감 방안을 강구하기 위하여 관련된 국내 외 규격을 기준으로 열회수형 환기장치의 크기, 풍량 및 흡음덕트 길이를 파라미터로 한 발생소음을 측정하여 비교하고 고찰하였다. 그 결과, 무향실에서 열회수형 환기장치에 대한 소음은 흡음덕트를 설치하지 않았을 경우에 소형 및 중형 모두 풍량에 관계없이 거의 대부분 소음기준인 50 dB(A) 보다 높게 나타났고, 흡음덕트를 설치하였을 경우에는 소음도가 감소됨을 알았다. 또한, 흡음덕트의 길이에 따른 주파수 대역별 음압수준은 소형과 중형 열회수형 환기장치에서 흡음덕트의 길이가 클수록 대체적으로 감소하였고, 풍량이 클수록 대체적으로 음압수준이 증가하였다.

실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구 (An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test)

  • 김항;박현구;구희모;김선우
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.