• 제목/요약/키워드: Sound insulation performance

검색결과 244건 처리시간 0.033초

축소시편 실험을 통한 공기전달음 차단성능 분석 (Analysis of airborne sound insulation performance by the experiment using small size specimen)

  • 김항;박현구;구희모;김선우
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

스터드 형상에 따른 Dry Wall의 차음성능변화 (Sound Insulation Performance According to Stud Shape of Dry Wall)

  • 안장호;김경호;이준서;김성훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.407-412
    • /
    • 2013
  • In dry wall, noise is passed through gypsum board and stud. Noise makes gypsum board vibration. Then, the vibration passes through stud and gypsum board as resonation. And radiation as noise from surface of gypsum board into adjacent room. At this moment, according to thickness, placement and cross-section of stud, noise transmission ratio changes. Thicker stud has better sound insulation performance. Studs are apart from each other, has better sound insulation performance. But, single stud structure has restriction of thickness and arrange of studs. In this article, Sound insulation performance varies depending on the shape of the studs were studied.

  • PDF

Evaluation of Sound Insulation Performance of Extruded Cement Panel with a-Hemihydrate Gypsum

  • Kim, Jin-Man;Choi, Duck-Jin
    • 한국건축시공학회지
    • /
    • 제12권6호
    • /
    • pp.575-585
    • /
    • 2012
  • The extruded cement panel, which has many advantages as a prefabricated method, has been limited in its application due to its low fire-resistance. However, an extruded cement panel produced by mixing a-hemihydrate gypsum offers dramatically improved fire-resistance and is expected to have wide-ranging applications in the construction sector as an interior material or partition wall between housing units. Sound insulation performance is very important for the partition wall between housing units. In this study, the sound insulation performance of the extruded cement panel produced through the mixture of a-hemihydrate gypsum is reviewed in order to determine its usability for a partition wall between housing units and for interior materials. Through the review it was found that the wall formed using the extruded cement panels produced by mixing the a-hemihydrate gypsum have ★★★ class in sound insulation test, equal or superior compared with the other two types of extruded cement panel walls currently available in the market.

철도차량 내장재용 복합재료 패널의 차음성능에 관한 연구 (A Study on the Sound Insulation Performance of the Composite-Material Panel for Railroad Vehicle)

  • 김봉기;김재승;김현실;강현주;김상렬
    • 한국철도학회논문집
    • /
    • 제6권1호
    • /
    • pp.10-14
    • /
    • 2003
  • Since most of main noise sources of the railroad vehicle are transmitted to the passenger's ear through the vibration of the panel, the sound insulation performance of the panels should be high enough to protect the passenger's ear from the noisy environment. Specifically, the composite materials which are generally used for reducing the weight of the vehicle compartment have the low insulation performance, thus noise control actions should be taken appropriately by considering the insulation performance of the panels. In this study, the insulation performances of the inner/outer panels of the compartment are evaluated. In addition, the contribution of the insulation performance of aluminum door is estimated and compared to those of composite panels. The results can furnish an in-depth understanding of the insulation characteristics of the panel of railroad vehicle.

틸팅열차 측면재의 차음 전략 (Sound Insulation Strategy of the Side Panels in a Tilting Train)

  • 김석현;서태건
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.33-38
    • /
    • 2011
  • In an express tilting train, side wall insulating the noise from the exterior sound source consists of two parts. One is the layered composite panel including aluminum honeycomb, glass wool and nomex honeycomb. The other is the double glazed window. In this study, sound insulation performance of the two parts is investigated by mass law and experiment. Based on ASTM E2249-02, the intensity sound transmission loss (TL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance in respect of weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy for the interior noise reduction is investigated.

  • PDF

바닥충격음 차단성능 기준설정 고찰 (A Consideration on the Establishment of Standard level for Floor Impact Sound Insulation)

  • 송민정;기노갑;장길수;김흥식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2001
  • Recently the impact sound insulation performance is regarded as one of the most import factors in determining the quality of housing environment. In order to reduce the impact sound level transmitted through the floors and structures, establishing the standard level of impact sound insulation performance is needed. In this consideration, The effecting facts for the standard insulation level is reviewed.

  • PDF

바닥마감재에 의한 바닥충격음 차음특성 연구 (A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings)

  • Gi, No-Gab;Kwon, Hyun-Jong;Song, Min-Jeong;Kim, Sun-Woo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.368.2-368
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound insulation performance of materials and elements used in building is falling down as they become thicker and lighter Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. (omitted)

  • PDF

음장제어용 막재료의 음향 및 단열특성 (Sound Absorption and Thermal Insulation Characteristics of Membrane Used for Sound Field Control)

  • 정정호;김정욱;정재군;조병욱
    • 한국소음진동공학회논문집
    • /
    • 제22권2호
    • /
    • pp.103-114
    • /
    • 2012
  • Nowadays membrane material is widely used for large indoor spaces and long spaces such as traditional market. Thermal insulation and sound field control performance is considered as a main properties for design of such buildings. In this paper sound absorption and thermal insulation properties of membrane material was investigated. Firstly, normal incidence sound absorption coefficient of 10 kinds of glass wool textiles showed that sound absorption coefficient was increased in proportion of thickness and surface density of textile. Sound absorption coefficient of 4 kinds of sound absorptive inner membrane with outer membrane was tested in the reverberation chamber. Sound absorption coefficient of mid frequency range was about 0.4 ~ 0.6. Also, sound absorption coefficient was changed by the air space behind the membrane material. Secondly, sound field control performance was investigated using mock-up space. By the installation of sound absorption membrane material, reverberation time was decreased and speech intelligibility was increased. Finally, thermal resistance and room temperature in two kinds of mock-up rooms were tested, simultaneously. Results of thermal properties showed thermal insulation properties ware increased by adding inner membrane material underneath the outer membrane.

현장실험을 통한 목조바닥의 구성요소가 충격음 차단성능에 미치는 영향 평가 (Evaluation on Effect of Constitution of Timber Framed Floor on Insulation Performance Against Impact Sound by Field Measurements)

  • 박주생;이상준;김세종
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권6호
    • /
    • pp.431-444
    • /
    • 2012
  • 바닥구조의 충격음 차단성능은 바닥의 구성요소에 의해 많은 영향을 받는데, 그중 목조 바닥구조의 경우 중량의 흡읍층과 바닥구조의 강성이 주요한 영향인자로 고려되어 왔다. 본 연구에서는 국내 시공된 목조 건축물에 대해서 현장 실험을 통해 바닥 구성요소가 충격음 차단성능에 미치는 영향에 대해서 살펴보았다. 목조 바닥의 충격음 차단성능은 상대적으로 낮은 저주파수 대역에서의 음압레벨에 의해 전체적인 성능이 좌우되었으며, 흡읍층과 바닥구조의 강성 보강에 의해 저주파수 대역 음압레벨을 감소시켜 충격음 차단성능을 향상시킴을 알 수 있었다. 특히, 바닥난방을 위해 설치되는 시멘트 몰탈층과 같은 충격음 흡수층과 원래 경간의 중간 지점에 보를 설치하여 장선 경간을 줄여줌으로써 목조 바닥의 강성을 증가시킨 경우에 중량 충격음 차단성능이 크게 향상되었다.

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF