• 제목/요약/키워드: Sound absorption ratio

검색결과 51건 처리시간 0.026초

인공경량골재를 이용한 철도 흡음블록의 흡음특성에 관한 연구 (A Study on the Sound Absorption Properties of Sound Absorption Block using by Artificial Light Weight Aggregate)

  • 강덕만;서재원;이인용;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.830-839
    • /
    • 2008
  • This study is designed to manufacture the upgraded sound absorption concrete by using foamed concrete by using artificial light weight aggregate which raises the continuous void ratio to increase the sound absorption ratio and improve the strength. In manufacturing the sound absorption block, the pre-foaming form is applied to generate continuous voids, controlling the density by the addition of bubbles. It is general that the more porosity creates, the weaker strength becomes. Each of specimens are used for this experiment and measured their absorption ratio to examine the absorption property depending on frequency. As a results of experiment, it is evaluated that the absorption capacity of the sound absorption block has relation to compression strength and surface shape.

  • PDF

잔향실법 흡음률 측정에 미치는 확산체의 영향 (The effect of diffusers on the measurement of sound absorption in a reverberation room)

  • 한희갑;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

배합요인에 따른 포러스 콘크리트의 흡음특성 (Sound Absorbing Characteristics of Porous Concrete according to Mixing Factor)

  • 이준;박승범;권혁준;김경훈;장영일;김형석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.489-492
    • /
    • 2003
  • The results of an experiment on the sound absorption of the porous concrete and its influence on the compressive strength are reported in this paper. Two different sizes of coarse aggregate of 5~13, 13~20mm, and the design void ratio of 20, 25 and 30 percent for a given size of aggregate were used. In the compressive strength, an aggregate of the size of 5~13mm is much higher strength than that of the 13~20mm, In the sound absorption experiment, the size of aggregate of 5~l0mm is much higher sound absorption than that of the 13~20mm. The sound absorption ratio was increased as the design void ratio. As a result, Porous concrete sufficiently have the performance of sound absorption.

  • PDF

연속공극을 갖는 기포콘크리트의 흡음특성에 관한 연구 (A Study on the Sound Absorption Properties of Cellular Concrete with Continuous voids)

  • 이승한;정용욱;박정준
    • 콘크리트학회논문집
    • /
    • 제15권4호
    • /
    • pp.566-573
    • /
    • 2003
  • 본 연구에서는 기포콘크리트속에 연속공극율을 증가시켜 흡음률을 높이면서 강도를 증진시킨 강체형 흡음재의 제조를 목적으로 하였다. 실험결과, 기포첨가량을 증가시켜 연속공극률을 높일수록 흡음률이 증가하였으며, 재료두께 5cm인 경우 연속공극률 40%이상에서 평균흡음률 70%이상을 만족하였다. 또한 흡음재 두께의 증가는 중저음영역에서 흡음률 증가를 나타내었으며 평균흡음률 70%이상을 만족하는 기포콘크리트의 비중은 재료두께 5cm에서 0.4이하, 7cm에서 0.6이하로 나타났다. 그리고 평균흡음률 70%이상 만족하는 비중 0.4인 기포콘크리트의 압축강도는 시멘트분말도 3,000$\textrm{cm}^2$/g의 경우 1.37MPa이나, 시멘트분말도 8,000$\textrm{cm}^2$/g에서는 3.34MPa로 증가되었다. 따라서, 연속공극을 갖는 기포콘크리트의 압축강도는 시멘트분말도가 높을수록 증가하는 것으로 사료된다.

기포제 희석비율에 따른 기포콘크리트의 흡음특성에 관한 연구 (A Study on the Sound Absorption Properties of Foamed Concrete According to Dilution Ratio of Foaming Agent)

  • 강기웅;강철;김하석;곽은구;권기주;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.5-8
    • /
    • 2005
  • Sound absorbing performance is affected by porosity and continuity of void, therefore it is important to maintain stabilization of foam and to analyze properties of void pore in hardened state. The purpose of this study is to analyze the sound absorption properties and void characteristic of foamed concrete according to dilution ratio of foaming agent. The results of this experiment were as follows. It is determined that an increase in total and continuous void ratio is achieved by increasing of dilution ratio, and a shorter absorbing time was exhibited at a higher continuous void ratio. When the average void size of foamed concrete was below 1.5mm, the tendency of sound absorption coefficient compared with general sound absorber was appeared similarly.

  • PDF

흡음형 방음벽의 내부 구성에 따른 흡음특성 (Sound Absorbing Characteristics According to Interior Configuration of Noise Barrier)

  • 박진규;김상헌;김관주;박희준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.387-392
    • /
    • 2003
  • This study is put a focus on the identification of sound characteristics according to the interior configuration of sound absorption material and air gap. Noise barrier is general consists of front perforated panel, air layer, sound absorption material, air gap and back plate. Noise barrier is required to the NRC value of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of the perforated panel and the efficiency of the absorbing material. This study has observed the effect of opening ratio and hole size, the increase of sound absorbing performance by the configurations of sound absorption material and air gap. New designed noise barrier is achieved the acoustical performance of 0.87 the measurement in a reveration room.

  • PDF

Density Profile and Sound Absorption Capability of Ceramics Manufactured from Sawdust, Chaff and Charcoal: Effect of Carbonization Temperature and Mixing Ratio

  • Jung-Woo HWANG;Seung-Won OH
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권3호
    • /
    • pp.234-242
    • /
    • 2024
  • In this study, the effect of carbonization temperature and mixing ratio of ceramics manufactured from sawdust, chaff and charcoal on sound absorption performance and density profile was investigated. The density profile of ceramics prepared by the addition rates of sawdust, chaff and charcoal showed the highest value at 91.00% when the ratio of sawdust, chaff and charcoal was 50:25:15. However, the difference in density profile according to the addition rate was insignificant. The density profile of ceramics manufactured according to the carbonization temperature showed the highest value of 88.06% when manufactured at 800℃. However, it does not show any particular trend, so it is understood that the effect of the carbonization temperature on the density gradient is small. On the other hand, the sound absorption coefficients of ceramics prepared by the addition rates of sawdust, chaff and charcoal is between 0.3 and 0.4 at almost all frequencies when the addition rates of sawdust, chaff and charcoal are 50:30:10 and 50:35:5, respectively. Therefore, as the chaff particles increased, the sound absorption performance was improved. In addition, the sound absorption coefficients of the ceramics manufactured at each carbonization temperature showed the highest value in the ceramics manufactured at 1,200℃.

재생골재를 사용한 포러스 콘크리트의 흡음특성에 관한 연구 (Sound Absorbing Characteristics of Porous Concrete Using Recycled Aggregates)

  • 서대석;박승범;김정환;표구영;김범규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.485-488
    • /
    • 2003
  • The results of an experiment on the sound absorption of the porous concrete using recycled aggregates and its influence on the compressive strength are reported in this paper. The content of recycled aggregate of 0, 10, 30, 50 and 70%, and the design void ratio of 30 percent for a given size of aggregate were used. In the compressive strength, an aggregate of the size of 5~13mm is much higher strength than that of the 13~20mm, In sound absorption experiment, the sound absorption ratio was is subjected to decreased as the content of recycled aggregates was increased. As a result, Porous concrete using recycled aggregates and by-products sufficiently have the performance of sound absorption.

  • PDF

점토 소결재의 흡음특성에 관한 실험적 연구 (An Experimental Study on the Sound Absorption Property of a Sintered Clay Material)

  • 양윤상;이동훈;서은성
    • 한국소음진동공학회논문집
    • /
    • 제23권4호
    • /
    • pp.365-371
    • /
    • 2013
  • The purpose of this study is to develop a sound absorbing material for indoor which manufactured by a clay and binding material. The seven kind of sound absorbing specimens which sintered through a mold process at high temperature were manufactured for the purpose of testing sound absorption performance. The random and normal sound absorption coefficients were measured for the sintered clay sound absorbing specimens with different particle size, density and mixture ratio. From the experimental results, it was found that its particle size was closely related to the sound absorption performance. It was shown that the sintered clay sound absorbing specimen had the sound absorption properties of a fiber-type or a resonance-type sound absorbing material depending on the particle size.

랜덤입사방법에 의한 포러스 콘크리트의 흡음특성에 관한 실험적 연구 (The Study on Sound Absorbing Characteristics of Porous Concrete according to Reverberation Room Methods)

  • 서대석;박승범;조광연;장영일;김형석;이윤선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.568-571
    • /
    • 2004
  • This research estimated the physical. mechanical characteristic and the character of sound absorption according to target void ratio of porous concrete and the mixing ratio of recycled aggregate for the valid utilization of recycled aggregate using waste concrete and sound reduction out of a road, a railway, a residential street, and a downtown area. As a result of the test, compressive strength tended to be a radical strength fall when target void ratio was $25\%$ and contents of recycled aggregate exceeded over $50\%$. Also, the character of sound absorption of porous concrete which used recycled aggregate using waste concrete was the most excellent when target void ratio was $25\%$, and the influence by contents of recycled aggregate was trivial. Therefore, when the strength and the character of sound absorption of porous concrete are considered, it is proved valid that proper target void ratio was $25\%$ and contents of recycled aggregate using waste concrete was $50\%$ or so.

  • PDF