• 제목/요약/키워드: Sound Measurement

검색결과 874건 처리시간 0.036초

지능형 로봇을 위한 GCC-PHAT 기반 음원추적 기술의 성능분석 (Performance analysis of GCC-PHAT-based sound source localization for intelligent robots)

  • 박범철;반규대;곽근창;윤호섭
    • 로봇학회논문지
    • /
    • 제2권3호
    • /
    • pp.270-274
    • /
    • 2007
  • In this paper, we present a Sound Source Localization (SSL) based GCC (Generalized Cross Correlation)-PHAT (Phase Transform) and new measurement method of angle with robot auditory system for a network-based intelligent service robot. The main goal of this paper is to analysis performance of TDOA and GCC-PHAT sound source localization method and new angle measurement method is compared. We use GCC-PHAT for measuring time delays between several microphones. And sound source location is calculated by using time delays and new measurement method of angle. The robot platform used in this work is wever-R2, which is a network-based intelligent service robot developed at Intelligent Robot Research Division in ETRI.

  • PDF

Resources for Success in Experiment: Goldingham's Measurement of the Velocity of Sound

  • Ku, Ja-Hyon
    • 한국음향학회지
    • /
    • 제31권4호
    • /
    • pp.253-259
    • /
    • 2012
  • Goldingham's measurement of the velocity of sound undertaken in the early nineteenth century was the first large-scale measuring enterprise which considered various meteorological factors such as temperature, humidity, atmospheric pressure, the direction of the wind, etc. Goldingham's successful performance of measuring the velocity of sound by employing the sounds of cannons as sound source in Madras (now Chennai), a colonial region of India, for one and a half years was supported by material, institutional and social resources. As the official astronomer at the Madras Observatory, he was benefitted by the undemanding employment of accurate measuring instruments under the support of the Madras Army enabled him to gain reliable data and his reputation as professional experimentalist facilitated the acknowledgment of their trustworthiness.

Measurement of Sound Speed Following the Fluid Temperature Using Acoustic Inspection Device

  • Jeon, E.S.;Kim, W.T.;Kim, I.S.;Park, H.
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.207-211
    • /
    • 2010
  • In this paper, the fluid AID(acoustic inspection device) was developed to measure SOS(speed of sound) since fluids used in most of industrial fields have different properties and its equipment is highly expensive. From AID developed, it is intended to get potentially the capability to distinguish the kind of fluid using the measurement by the SOS at various fields. In order to measure the sound speed of specific fluids, the measurement system and ultrasonic sensors are composed. The fluid used in the experimental work are soybean oil, glycerin, diesel oil and the error of time difference due to the container wall is extracted for preliminary experiment. As results, the variations of sound speed according to the temperature change of target fluid were analyzed and the polynomial equations were proposed.

경량충격음 차단성능 실험실 측정방법 고찰 (A Survey on the Laboratory Measurements of Impact Sound Insulation of Floors)

  • 송민정;장길수;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.976-979
    • /
    • 2004
  • The KS of 'Laboratory Measurement of Impact Sound Insulation of Floors' is not established yet. To establish this KS, present conditions of domestic laboratory test facilities for measuring impact sound insulation of floors in laboratory and current researches were reviewed As a result the outline of 'Laboratory Measurement of Impact Sound Insulation of Floors' is suggested.

  • PDF

벽식구조 표준시험동에서 중량충격음장에 관한 연구 (Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure)

  • 유승엽;이신영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

자동차의 음향잡음의 원인규명 방안 (Acoustic Noise Source Identification in the Automotive Industry)

  • Hall, Paul
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.91-97
    • /
    • 1996
  • We have all heard sounds that did not sound "right" while riding in an automobile. Objectionable sounds are difficult to find and understand because the sound field is complex and dynamic in the near field of an automobile. Many different noise sources and transmission paths must be understood before an engineering change can be recommended. This paper reviews the fundamental characterization of sound and chscusses the Sound Intensity measurement technique. Sound intensity measurements locate sources and sinks of acoustic energy. Used with narrowband analysis equipment, acoustic noise sources can be identified. Sound intensity measurements are made -in-situ and do not require specmi anechoic facilities. The measurement results in a vector representation of the near field sound field and can discriminate between multiple sound sources.d sources.

  • PDF

음향파워 측정 시 오차에 대한 고찰 (A Study on the Errors at the Measurement of Sound Power)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.917-924
    • /
    • 2012
  • Noise power of large machineries, such as textile looms, winders, and twisting machines, is often measured in a reverberant space because they cannot be installed and operated in an anechoic chamber due to their size, weight, and operating conditions. Factors affecting the measurement error of an in-situ noise power measurement include the nonuniform reverberation time and the direction of sound intensity vector which is usually regarded as normal to the measurement surface. In this study errors due to these factors are estimated with the aid of numerical simulation based on the ray-tracing technique. The averaging of reverberation times measured at several points on the measurement surface is suggested to reduce the errors from nonuniform absorption. Also the direction cosine of each surface element is taken into account, which as a whole is represented as a solid angle of the measurement surface.

차음상자와 전자청진기로 기록된 장음에 의해서 깨어 있는 흰쥐의 위수축력 측정 (Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box)

  • 윤상협
    • 대한한방내과학회지
    • /
    • 제35권4호
    • /
    • pp.439-447
    • /
    • 2014
  • Objectives: The aim of this study was to investigate whether 1) variation of bowel sounds recorded stably through an electronic stethoscope in a sound insulation box can be related with that of gastric contraction and 2) if they are thus useful tool in the measurement of the gastric contractility in awake rats or not. Methods: Electrical potentials of both electronic stethoscope of bowel sound and force transducer were recorded simultaneously and continuously in the sound insulation box for the starting 30 min of basal state, and then 30 min of 0.2 ml normal saline administration, finally 30 min of 0.2 ml mosapride citrate solution (100 mg/Kg) in rats. Each motility index of normal saline or mosapride citrate treatment was presented with ratio against the basal state by using integrated electrical potentials. Results: A pattern of significance of gastric contractility between bowel sound and force transducer was showed analogously. Conclusions: The amplitude of bowel sounds recorded by the electronic stethoscope related with the intensity of gastric contractions. This confirms that a sound insulation box and electronic stethoscope are useful tools in the measurement of the gastric contractility of awake rats.

다목적 야외경기장의 음향특성에 관한 연구 II -서울월드컵 경기장의 전기음향시스템고찰과 음향측정을 중심으로- (The Properties of Acoustic in Multi-purpose out-door Stadium II - a case study of seoul world cup stadium measurement -)

  • 김정중;손장열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.731-739
    • /
    • 2002
  • recently out door stadiums have been built as multi purpose stadium for athletic sports It hold but also various events and huge concerts. in the past, out-door stadium usually was built, but recently the out-door stadium which of the 50 % of roof covered by doom have been built increasingly. as the result, the sound obstacle is becoming very important. but a design of sound has become unplaned except some of the stadium, also rarely been built by sound-absorption material. as the result, the purpose of this study is investigating, analyzing the theory for plan of electric acoustic sound, a drawing of acoustic design and measurement a result value, comparison, evaluating a main sound factor with criteria of the Seoul City design. and reservation time, clearness, sound pressure level suitable for using purpose, so the necessary quantities will be added to financial budget of building acoustic design. and For verification, this contains acoustic analyser measurement and computer simulation and this study will find the solution of helping method.

  • PDF

기준음원의 교정 절차 개발 및 불확도 평가 사례 (Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation)

  • 서재갑;조완호
    • 한국음향학회지
    • /
    • 제43권3호
    • /
    • pp.344-350
    • /
    • 2024
  • 기준음원은 음향파워 측정에 활용되는 중요한 기준기로, 국제 표준으로 그 사양이 규정되어 있으며, 측정 표준 분야에서 주요 교정 품목으로 분류되고 있다. 이러한 기준음원은 공급 전압에 의하여 그 출력이 영향을 받기 때문에 각국에서 자체적으로 교정 서비스 체계를 확보할 필요가 있다. 본 연구에서는 잔향실 조건에서 기준음원을 교정하는 절차를 수립하고 불확도를 평가하였다. 교정 절차는 기본적으로 음향 파워의 정밀급 측정과정을 적용할 수 있으며, 여기서는 ISO 3741의 잔향실을 활용한 측정 방법을 검토하였다. 이를 위한 측정 시스템을 구성하고 실제 2종의 기준 음원에 대하여 측정을 수행하고 측정 불확도를 산출하였다. 측정 예를 통하여 잔향실 내 음압 분포의 불균일성과 체적 측정 불확도가 전체 불확도에 기여가 큰 것을 확인하였다. 추가적으로 입력 전압에 대한 영향을 실험적으로 검토하여 음향 파워 측정에서 반영할 수 있는 불확도 기여량을 검토하였다.