• Title/Summary/Keyword: Solution Mixing Method

Search Result 239, Processing Time 0.028 seconds

Enhancement of Mixing Performance in Viscous Liquid Using an Electromagnetically Driven Microrobot (초소형 로봇을 이용한 점도성 유체의 혼합 효율 향상)

  • Song, Hyeonseok;Park, Yuna;Chung, Sang Kug
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.53-58
    • /
    • 2018
  • This paper presents an electromagnetically driven microrobot for the enhancement of mixing performance in high viscous liquid media such as blood and bone marrow. First, an electromagnetic system was fabricated, and the magnetic flux density generated from the system was compared with the theoretical value. Second, the reciprocating motion of the microrobot was demonstrated in microchannel using electromagnetic system. As a proof of concept, the mixing performance by the electromagnetically driven microrobot in high viscous liquid was investigated using safranin solution. As a result, it was completely mixed within 140 s with the reciprocating motion of the microrobot while it took 1680 s for natural diffusion. In addition, the mixing efficiency was quantitatively evaluated through a mixing index obtained by an image analysis. The proposed method provides not only wireless actuation of a microrobot with a simple design but also high mixing performance in variety of high viscous liquid media.

A Turbidimetric Determination of Protein by Trichloroacetic Acid

  • Choi, Wahn-Soo;Chung, Kae-Jong;Chang, Man-Sik;Chun, Jae-Kwang;Lee, Hyang-Woo;Hong, Sung-Youl
    • Archives of Pharmacal Research
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 1993
  • Based on the turbidimetric response of protein with 50% trichloroacetic acid (TCA), this study aims to introduce an assay method for protein in solution. The standard procedure consists of mixing equal volume of sample solution (standard or unknown) with 50%-TCA solution and measuring the absorbance at 450 nm after 20 min. The absorbances of the solutions were almost stable over 120 min at room temperature. This assy method is simple, reproducible, and tolerant to many interfering substances. It can detect less amount than $10\mu$g/ml of bovin serum albumin. The assay method has low protein-to-protein variability over wide range of molecular weight.

  • PDF

Type of Solution and the Effects of Temperature Change in a Rapid Appraisal of Cement Fineness with a Liquid Densimeter (액체밀도계에 의한 시멘트의 분말도 신속평가에서 용액 종류 및 온도변화의 영향)

  • Lee, Jae-Jin;Kim, Min-Sang;Moon, Byeong-Yong;Kim, Yeong-Tae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.167-168
    • /
    • 2017
  • With the recent increase in demand for construction there has been an increase in the use of the raw material cement when mixing concrete; managing quality of cement powder, therefore, is most important. Therefore this study sought at first to develop a rapid appraisal using the Hydrometer method researched previously, for it was thought that when suspending cement in a solution and applying the Hydrometer method to it the temperature changes in the solution would have a great effect on the density value of the Hydrometer method; yet there has been no report of such influence factors. Therefore after analyzing the influence factors that the type of suspending solution and changes in temperature could have on rapid appraisal of fineness, using the Hydrometer method, this study was able to determine that using water at 20℃ was the most appropriate, and with every temperature increase of 10℃ the value of fineness should also be increased above or below 7% as well.

  • PDF

The role of large-scale structures in mixing layers (혼합층에서의 큰-크기구조의 역할)

  • Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.316-325
    • /
    • 1998
  • The objective of this study is to investigate the role of large-scale coherent structures in a spatially developing plane mixing layers. To achieve this, we have to look into the mutual interactions between three-dimensional large-scale coherent structures and the mean flow. Our attention will be focused on the energy exchange mechanism between the various modes, and the effects of the nonlinear evolution of the phases of the interacting modes. Linear stability of the three-dimensional viscous shear layer is formulated and solved as the basis for the solution of the nonlinear formulation based on the energy method. The importance of the initial conditions that may affect the evolution of the flow has been examined. It has been numerically calculated the nonlinear effects arising from the interactions among the three-dimensional large-scale coherent structures in a spatially developing plane mixing layers. The results of this study provide useful parametric information for the control of shear layer in practical applications in the mixing and transport augmentation.

A Study on Dry Film Formation of Clay Solution (점토 혼합액의 건조박막 형성에 관한 연구)

  • 박헌휘
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.180-186
    • /
    • 1998
  • In this study, the effect of shear rate on the viscosity variation is examined to understand the flow characteristics of the mixture of bentonite and water. The variation of film thickness according to mixing ratio and viscosity is measured to characterize the film formation. And, the separation of dried film is studied according to film thickness. Specific surface area affecting on adsorption capability is measured using BET method. The viscosity decreases and the film thickness increases as the mixing ratio increases. The separation characteristic of dried film is suitable within a range of 40 to 150 ${\mu}{\textrm}{m}$ in film thickness and 5 to 10% in mixing ratio.

  • PDF

Study ascorbic acid in apple by treatment of mixer and salt solution (Mixer 및 소금물 처리에 의한 사과의 Asxorbic Acid 함량의 변화)

  • 강신주
    • Journal of the Korean Home Economics Association
    • /
    • v.8 no.1
    • /
    • pp.87-92
    • /
    • 1970
  • Recently it has become a common belief that ascorbic acid comes to break up in the process of making its color after peeling it. In this study the writer has attempted to observe whethier ascorbc acid really breaks up or not, what percentage of salt is needed in water to keep ascorbic acid in the best condition. Ascorbic acid was quantified by the spectrophotometric method. The results were obtained as follows; It seems that ascorbic acid does not break up considerably in mixing by the imxer for two minutes and if the mixing lasts longer ascorbic acid breaks up by heat and presumably by enzyme and oxidation. Generally at our home the breaking of ascorbic acid usually does not appear so much as only two minutes, mixing gives us the desirable result.

  • PDF

A Numerical Study on Mixing Characteristics of the Chemical Injection Tank

  • Chang, Keun-Sun;Park, Byeong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.58-67
    • /
    • 1997
  • A numerical study has been peformed to investigate the flow and mixing characteristics of a chemical injection tank in the chemical and volume control system (CVCS) of Yonggwang 5&6 (YGN 5&6). This study was undertaken to provide a basis for modification of the previous design (YGN 3&4) which gave a lot of difficulties in installation and operation of the chemical injection system during the start-up test because it needs a special reciprocating pump with a high actual head. For the tank of length-to-diameter ratios (L/D) of 1,2 and 3, each with and without a baffle inside, calculation results were obtained by solving the unsteady laminar two-dimensional elliptic forms of governing equations for the mass, momentum and species concentration. Finite-difference method was used to obtain discretized equations, and the SIMPLER solution algorithm, which was developed based on the staggered grid control volume, was employed for the calculation procedure. Results showed that the baffle is very effective in enhancing the mixing in the tank and that a baffle should be installed near the tank entrance in order to 110 chemicals into the reactor coolant system (RCS) within the operating time required.

  • PDF

Dissolution Characteristics of Copper Oxide in Gas-liquid Hybrid Atmospheric Pressure Plasma Reactor Using Organic Acid Solution

  • Kwon, Heoung Su;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.229-233
    • /
    • 2022
  • In this study, a gas-liquid hybrid atmospheric pressure plasma reactor of the dielectric barrier discharge method was fabricated and characterized. The solubility of copper oxide in the organic acid solution was increased when argon having a larger atomic weight than helium was used during plasma discharge. There was no significant effect of mixing organic acid solutions under plasma discharge treatment on the variation of copper oxide's solubility. As the applied voltage for plasma discharge and the concentration of the organic acid solution increased, the dissolution and removal power of the copper oxide layer increased. Solubility of copper oxide was more affected by the concentration in organic acid solution rather than the variation of plasma applied voltage. The usefulness of hybrid plasma reactor for the surface cleaning process was confirmed.

Absolute Activity Measurement of $^{137}Cs$ Solution by the Tracer Method (추적자 방법에 의한 $^{137}Cs$용액의 방사능 절대측정)

  • Park, Tae-Soon;Oh, Pil-Jae;Hwang, Sun-Tae;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.107-114
    • /
    • 1987
  • Using a solution of $^{137}$ Cs as a tracer, radioactivity of a $^{137}$ Cs solution is measured by coincidence and anticoincidence counting methods. Sample sources in this study are fabricated by mixing $^{137}$ Cs with tracer, and the mixing ratios are 1/3 and 1/5, respectively in coincidence and anticoincidence methods. Specific activities of a $^{137}$ Cs solution are calculated by means of f-channel low energy threshold level variation and efficiency extrapolation. The results obtained by coincidence and anticoincidence counting methods are 552.78 kBq/g and 554.32kBq/g, respectively on the reference date and the combined uncertainties are 1.60kBq/g and 1.51kBq/g for each method. These two results show a good agreement within the uncertainty range.

  • PDF