• Title/Summary/Keyword: Solid-liquid extraction

Search Result 289, Processing Time 0.025 seconds

Optimization of Extraction Conditions for Total Phenolics from Sapium japonicum Using a Pressurized Liquid Extractor

  • Kim, Mi-Bo;Park, Jae-Sung;Lim, Sang-Bin
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.996-1000
    • /
    • 2009
  • Sapium japonicum was extracted by a pressurized liquid. Operating parameters such as the type and the ratio of solvent to water, temperature, pressure, and number of extractions were investigated as the main variables that influence the extraction efficiencies of total phenolics (TP). MeOH extracted the highest level of TP as 50.4 mg GAE/g compared to 48.8 and 27.2 mg GAE/g with $H_2O$ and EtOH, respectively. $EtOH:H_2O$ (40:60, v/v) was found to be the best solvent for TP extraction as 90.3 mg GAE/g compared to 85.0 and 84.3 mg GAE/g in 40:60 and 60:40 of $MeOH:H_2O$, respectively. TP were increased with the increase of the number of extraction steps. TP content was increased by 11% as the extraction temperature was increased from 40 (97.4) to $50{\circ}C$ (108.3 mg GAE/g). The optimum extraction conditions of TP were; extraction solvent, $EtOH:H_2O$ (40:60, v/v); temperature, $50{\circ}C$; pressure, 10.2 MPa; 2 extraction steps.

Analysis of Heterocyclic Amines in Human Urine Using Multiple Solid-Phase Extraction by Liquid Chromatography/Mass Spectrometry

  • Cha, Hyun-Jeong;Kim, Nam-Hee;Jeong, Eun-Kyung;Na, Yun-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2322-2328
    • /
    • 2010
  • A multiple solid-phase extraction (SPE) method was used with liquid chromatography, coupled with mass spectrometry (LC/MS), for the analysis of heterocyclic amines (HCAs) in human urine. Separation efficiencies based on the pH of the mobile phase and the types of columns were compared. An amide column showed better baseline separation and narrower HCA peak widths at pH 5.0 for the mobile phase than a $C_8$ column. Each SPE step, HLB, MCX, and HybridSPE, was optimized by controlling the pH conditions. The combined method with the three SPEs effectively removed interfering species that cause ion-suppression during HCA detection. Validation of the method, performed with SIM and SRM detection, showed correlation coefficients above 0.991 in the range 0.3 - 16.7 ng/mL. Recovery rates were 45.4 - 97.3% on the $C_8$ column and 71.8 - 101.4% on the amide column, and method detection limits were 0.11 - 0.65 ng/mL on the $C_8$ column and 0.12 - 0.48 ng/mL on the amide column. This method using multiple SPEs offers significant benefits for high-throughput determination of HCAs in urine.

An extraction method and residues of benzimidazole fungicides in soybean sprouts (콩나물중 benzimidazole계 농약의 추출방법과 잔류성)

  • Park, Jun-Jo;Yong, Kum-Chan;Jeung, Jin-A
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.1
    • /
    • pp.26-31
    • /
    • 2000
  • An analytical method was approached to determine the residues of benzimidazole fungicides in soybean sprouts and was compared with traditional solvent-based method of extraction, solid phase extraction(SPE) and matrix solid phase dispersion(MSPD). The recoveries of carbendazim for liquid-liquid extraction (LLE), SPE and MSPD in soybean sprouts were $69.25{\sim}79.16$, $79.99{\sim}90.42$ and $92.40{\sim}98.48%$, respectively. The recoveries of thiabendazole for LLE, SPE and MSPD in soybean sprouts were $64.86{\sim}83.26$, $79.12{\sim}94.04$ and $65.44{\sim}73.92%$, respectively. The residues of carbendazim by elapsed time under our cultivated soybean sprouts program found $0.10{\sim}0.25$ mg/kg after 5 days and trace concentration of carbendazim was detected after 7 days. Of the 448 samples analyzed, less than 1.5% had residues of carbendazim ranged from 0.05 to 0.37 mg/kg.

  • PDF

Optimization of analytical conditions for the determination of nitrosamines in chlorinated tap water by high performance liquid chromatography (액체크로마토그래피를 이용한 수돗물 중 nitrosamine 화합물 분석의 최적화)

  • Han, Ki-Chan;Kim, He-Kap
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.551-559
    • /
    • 2010
  • This study was conducted to establish an analytical method for the determination of seven nitrosamines in chlorinated tap water by precolumn derivatization followed by high performance liquid chromatography coupled with fluorescence detection. The derivatization procedure was optimized for denitrosation and dansylation, and then two extraction methods, liquid-liquid extraction (LLE) with dichloromethane and solid phase extraction (SPE), were compared. The SPE method employing the optimized derivation procedure showed higher extraction recovery (54.4-88.7%) and reproducibility (1.9-19.4%) than the LLE method (51.4-87.7% and 4.2-33.3%, respectively). The method detection limits were between 0.5 and 4.4 ng/L. When chlorinated water samples were collected from two treatment plants and ten household taps, and analyzed for nitrosamines, Nnitrosodimethylamine (NDMA) was the major compound found between 26.1 and 112 ng/L.

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

New Analytical Method of Cyclosporine A in Human Serum by High -performance Liquid Chromatography/Diode Array Detector and Its Application to Pharmacokinetics of Cyclosporine A in Human Volunteers

  • Kim, Eun-Young;Chung, Yeon-Bok;Kwon, Oh-Seung
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.423.1-423.1
    • /
    • 2002
  • A simple. specific and sensitive method for the determination of cyclosporine A (CsA) in human serum has been developed by a high performance liquid chromatography/diode array detector (DAD) and applied to pharmacokinetic study of CsA. This method involves the use of solid phase extraction procedure following rapid protein precipitation with zinc sulphate from 1 $m\ell$ of human serum, using a disposable $C_{18}$ extraction cartridge. (omitted)

  • PDF

Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples (HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석)

  • Kwak, Sun Young;Moon, Myeong Hee;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.519-528
    • /
    • 2006
  • An analytical method for the determination of thyroid hormones in urine samples has been studied by using solid-phase extraction and high-performance liquid chromatography/diode array detector/electro-spray mass spectrometry. Seven thyroid hormones were successfully separated by gradient elution on the reverse phase Hypersil ODS column (4.6 mm I.D., 100 mm length, particle size $5{\mu}m$) with ammonium formate buffer and acetonitrile, and UV spectra and mass fragment could be confirmed. The extraction recoveries of thyroid hormones in the urine samples (pH 3) were in the range of 89.0-113.1% with solid-phase extraction by C18, followed by elution with 4 ml of methanol/ammonium hydroxide (9 : 1). The calibration curves showed good linearity with the correlation coefficients ($r^2$) varying from 0.992 to 0.998 and the detection limits of all analytes were obtained in the range of 2-4 ng/ml (3.8-13.0 pmol/ml).

A Study of Analytical Method for Trace Metal Ions in Whole Blood and Urine by Inductively Coupled Plasma-Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 혈액 및 소변중 미량금속의 분석에 관한 연구)

  • Lee, Won;Hur, Young-Hoe;Park, Kyung-Su
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.281-291
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in blood and urine has been investigated by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Microwave oven was used for the pretreatment of blood samples using nitric acid and hydrogen peroxide in a closedvessel digestion system with 1 mL whole blood for 8 minutes. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Detection limits for Cu, Sn, and Bi by this method were 0.000375 ng/mL, 0.000297 ng/mL, and 0.000174 ng/mL, respectively. Recoveries of 99.1% for Cu, 102.5% for Sn, and 98.4% for Bi were obtained for the standard spiked NIST SRM 955a blood sample. The developed method was applied for whole real blood and urine samples.

  • PDF

Simultaneous detection of residual fungicide in Bean Sprouts by Solid-phase Extraction (고체상 추출법에 의한 콩나물 중의 잔류농약 동시 검출)

  • Lee, Myunghwoon;Lee, Taejoon;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.509-514
    • /
    • 1993
  • Benomyl, topsin-M and thiram been known as one of the seed disinfectant. For these studies benomyl, topsin-M and thiram simultaneously had been analyzed by high performance liquid chromatographic method using ODS cartridge, benomyl, topsin-M and thiram was chromatographed using an ODS column and eluent 40% Acetonitrile at a flow rate of 1ml/min. The UV Detector responses at 276nm.

  • PDF