• Title/Summary/Keyword: Solid-liquid extraction

Search Result 294, Processing Time 0.031 seconds

The Extraction and Derivatization of Organotins in Water Sample by Gas Chromatograph/Mass Spectrometer (기체크로마토그래프/질량분석기에 의한 물시료 중 Organotin의 추출 및 유도체 반응에 관한 연구)

  • Hong, Jee-Eun;Lee, Kang-Jin;Pyo, Hee Soo;Park, Song-Ja;Lee, Won
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.636-645
    • /
    • 2000
  • A method is described for the determination of organotins in water samples by GC/MS. Optimized derivatization methods for ethylation and hydrogenation of organotins were surveyed according to various reaction conditions such as time, pH and concentration of reagents. The organotins were extracted with n-hexane in presence of 0.1% tropolone and hydrogenated with sodium borohydride. Extraction recoveries of organotins with hydrogenation were in the range of 61-112%. After ethylation, organotins in water samples were extracted by liquid-liquid extraction (LLE) and solid-phase extraction (SPE). Using LLE, extraction recoveries were in the range of 74-113%. The recoveries ranged from 61-97% in the case of SPE with styrene-divinylbenzene copolymers. Method detection limits of hydrogenated and ethylated organotins ranged from 0.05 to 0.5 ng/ml and from 0.02 to 0.05 ng/ml, respectively.

  • PDF

Application of On-Line SPE-LC/MSD to Measure Perfluorinated Compounds (PFCs) in Water (On-Line SPE-LC/MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Jung, Jong-Moon;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • We applied a sensitive method based on on-line solid-phase extraction (SPE) and liquid chromatography/mass spectrometry (LC/MSD) using an electrospray interface for the determination of eleven perfluorinated compounds (PFCs) in water. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 mL water samples, recoveries were between $80.4{\pm}5.2%{\sim}109.5{\pm}1.4%$ and limit of quantification (LOQ) were 3.6~15.9 ng/L for the PFCs. The total PFCs concentrations of the tributaries and main stream of Nakdong River water samples were in the range of $8.0{\sim}678.6{\mu}g/L$.

Simultaneous analysis of sulfonamides in beef and pork by high performance liquid chromatography and electrospray ionization mass spectrometry (HPLC와 LC/MS에 의한 식육내 잔류 설파제의 동시 분석법)

  • 정봉수;박준조;금모래;김인경;박병옥;한정희
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.1
    • /
    • pp.17-29
    • /
    • 2004
  • A multiresidual analysis was performed to determine 12 sulfonamides(sulfacetamide, sulfadiazine, sulfisomidine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine, sulfamonomethoxine, sulfisoxazole, sulfamethoxazole, sulfaquinoxaline, and sulfadimethoxine) in beef and pork simultaneously. The multiresidual analysis for the sulfonamides currently used was able to analyze 5 kinds of sulfonamides at the same time. The method of this 12 sulfonamides multiresidual analysis in this study was matrix solid-phase dispersion(MSPD) by high performance liquid chromatography (HPLC) and liquid chromatography mass spectrometry (LC/MS). The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM: Ethylacetate(3:1), DCM:EA(9:1). Also, samples (84 beef and 205 pork samples) which were positive by EEC-4 plate test from 2001 to 2003 were tested to investigate the kinds of sulfonamides using HPLC. The results from the study were as follows; 1. The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM:Ethylacetate(3:1), DCM:EA(9:1). The method of extraction solvent with DCM:ethyl acetate(9:1) was the most excellent(87.7∼99.3%) in separation and reappearance. 2. In the LC/MS analysis. of sulfonamides, signal to noise ratio was showed relatively high in the positive mode and special ion in the quality analysis was determined via [M+H]$\^$+/ and m/z 156. A spectrum of sulfonamides was showed from all 12 sulfonamides. 3. The samples positive by the EEC-4 plate, a screening test method, were categorized by sulfonamides through Charm II and confirmed the kinds of sulfonamides through HPLC. 1) Among 84 beef samples positive by EEC-4 plate, 20 samples were positive by Charm II and identified as 7 sulfamethazine, 9 sulfadimethoxine, 1 sulfamonomethoxine and 3 unknown status. 2) Among 205 pork samples positive by EEC-4 plate, 42 samples were positive by Charm II and identified as 19 sulfamethazine, 1 sulfadimethoxine, 4 sulfamonomethoxine and 5 unknown status.

Optimization of fish oil extraction from Lophius litulon liver and fatty acid composition analysis

  • Hu, Zhiheng;Chin, Yaoxian;Liu, Jialin;Zhou, Jiaying;Li, Gaoshang;Hu, Lingping;Hu, Yaqin
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.2
    • /
    • pp.76-89
    • /
    • 2022
  • The Lophius litulon liver was used as raw material for the extraction of fish oil via various extraction methods. The extraction rate by water extraction, potassium hydroxide (KOH) hydrolysis and protease hydrolysis were compared and the results revealed the protease hydrolysis extraction had a higher extraction rate with good protein-lipid separation as observed by optical microscope. Furthermore, subsequent experiments determined neutrase to be the best hydrolytic enzyme in terms of extraction rate and cost. The extraction conditions of neutrase hydrolysis were optimized by single-factor experiment and response surface analysis, and the optimal extraction rate was 58.40 ± 0.25% with the following conditions: enzyme concentration 2,000 IU/g, extraction time 1.0 h, liquid-solid ratio 1.95:1, extraction temperature 40.5℃ and pH 6.5. The fatty acids composition in fish oil from optimized extraction condition was composed of 19.75% saturated fatty acids and 80.25% unsaturated fatty acids. The content of docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA) were 8.06% and 1.19%, respectively, with the ratio (6.77:1) surpassed to the recommendation in current researches (5:1). The results in this study suggest protease treatment is an efficient method for high-quality fish oil extraction from Lophius litulon liver with a satisfactory ratio of DHA and EPA.

Comparison of Liquid Chromatography-Mass/Mass Spectrometry (MS) and Gas Chromatography-MS for Quantitative Analysis of Indole-3-acetic acid and Indole-3-butyric acid from the Concentrated Liquid Fertilizer (Liquid Chromatography-Mass/Mass Spectrometry (MS)와 Gas Chromatography-MS를 이용한 농축 액상 비료제품 중 Indole-3-acetic acid 및 Indole-3-butyric acid 정량분석능 비교)

  • Kim, Jin Hyo;Park, Jong Min;Choi, Geun-Hyoung;Park, Yun-Ki;Im, Geon-Jae;Kim, Doo-Ho;Kwon, Oh-Kyung
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.1
    • /
    • pp.53-57
    • /
    • 2013
  • In here, we investigated the quantitative analysis method of indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA) with liquid chromatography-mass/mass spectrometry (LC-MS/MS) or gas chromatography-MS. Two ways of clean-up process were investigated for LC-MS/MS instrumental analysis of IAA, but both a simple dilution and hydrophile-lipophile balance (HLB) solid phase extraction (SPE) were not met the optimal recovery rates for quantitative analysis. On the other hand, the clean-up method for GC-MS was finally optimized through HLB-SPE from 250-folds diluted sample and methylation with trimethylsilyl chloride in methanol for 4 h. The limit of detection for methyl ester of IAA and IBA were both 1.4 mg/L, and recovery rates showed 93-107% from the concentrated liquid fertilizer.

Comparison of pretreatment methods for tetracyclines analysis by HPLC (테트라싸이클린계 잔류항생물질 분석을 위한 전처리방법 비교)

  • Kim, Dong-Eon;Hwang, Lae-Hwong;Yun, En-Sun;Ham, Hee-Jin;Yang, Yoon-Mo;Kim, Chang-Gi;Ki, No-Jun;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.26 no.3
    • /
    • pp.199-202
    • /
    • 2003
  • Solid phase extraction(SPE) and matrix solid phase dispersion(MSPD) have been studied as preparation procedures for tetracyclines analysis by high-performance liquid chromatography(HPLC) in meat. The recovery range was 74${\sim}$98% for SPE, and 72${\sim}$93% for MSPD at spiked levels of 100ng/g for oxytetracycline(OTC), tetracycline(TC), chlortetracycline(CTC), and doxycycline(DC). The detection limits were 15${\sim}$78ng/g for SPE and 25${\sim}$84ng/g for MSPD, respectively. Analytical method was HPLC with UV detector. The purpose of this study was developing a practical, accurate and precise method for rapid extraction and quantitation of tetracycline residues in meat.

Matrix Solid-Phase Dispersion (MSPD) Isolation and Liquid Chromatographic Determination of Residual Furazolidone in Eggs (MSPD 전처리법과 HPLC를 이용한 Furazolidone의 계란내 잔류분석)

  • 서계원;이재일;이채용;이정치
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.2
    • /
    • pp.43-50
    • /
    • 2003
  • A liquid chromatographic method, using matrix solid-phase dispersion (MSPD) is developed for the extraction of residual furazolidone in chicken eggs. Blank or fortified egg samples (0.5 g) were blended with Octadecylsilyl (Bulk $C_{18}$, 40${\mu}{\textrm}{m}$, 18%. load, endcapped. 2 g) derivatized silica. After homogenization, $C_{18}$/egg and Na$_2$S $O_4$matrix were transferred to a column made of 10 ml glass syringe and filter paper and compressed 4.0∼4.5 ml volume. The column was washed with 8 ml of hexane and dried under $N_2$ gas. Furazolidone was eluted with acetonitrile (8 ml) under gravity. The eluate containing furazolidone was free from interfering compounds when analyzed by HPLC with UV detection (365 nm, photodiode array). Calibration curves were linear (r = 0.99985) and inter- (1.47%) and intra-assay (5.29%) variabilities for the concentration range examined (7.8∼497 ng/g of eggs, 20 ${mu}ell$ injection volume) were indicative of an acceptable methodology for the analysis of furazolidone. Average recovery of furazolidone added to egg was 96.2%. The limit of detection for the proposed method was 1 ng/g for furazolidone. The method using MSPD is proposed as an alternative assay to the classical method which involves the use of large volumes of a harmful solvent and requires a long tedious separation and clean-up processes prior to its determination.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Investigation of difference of Gwakhyangjeonggi-san decoctions produced by different pressure levels and various extraction times (전탕 압력과 전탕 시간의 차이에 따른 곽향정기산 전탕액 비교)

  • Kim, Jung-Hoon;Lee, Nari;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • Herbal Formula Science
    • /
    • v.22 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Objectives : Gwakhyangjeonggi-san (GJS) which consists of 13 herbal medicines has been used to treat gastrointestinal disorders caused by common cold. This study was performed to compare GJS decoctions produced using different pressure levels for various extraction times. Methods : Decoctions were prepared by the pressure levels of $0kgf/cm^2$ (non-pressurized) or $1kgf/cm^2$ (pressurized) for 30-180 min. The extraction yield, total soluble solid content (TSSC), and hydrogen ion concentration (pH) were measured, and the contents of the nine marker compounds were determined using high performance liquid chromatography. Results : The higher pressure and longer extraction time significantly increased TSSC value, while decreased the pH value. However, only extraction time affected the extraction yield of pressurized decoction. Variation of the amounts of chemical compounds was shown in pressurized and non-pressurized decoctions during extraction time. The result of regression analysis showed that pressure and extraction time can influence to extraction yield, TSSC, pH, and the content of chemical compounds. Conclusions : This study suggests that the pressure and extraction time can significantly affect the extraction efficiency of components from GJS decoctions.

Optimization Condition of Trace Analysis of Fuel Oxygenated Compounds Using The Design of Experiment (DOE) in Solid-Phase Microextraction with GC/FID (고체상미량분석법(SPME-GC/FID)에서 실험계획법을 이용한 연료첨가제 미량분석의 최적조건)

  • An, Sang-Woo;Lee, Si-Jin;Chang, Soon-Woong
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • In this study, Solid-phase micro-extraction (SPME) with Gas Chromatograph using Flame Ionization Detector (GC/FID) was studied as a possible alternative to liquid-liquid extraction for the analysis of Methyl tert-butyl ether (MTBE) and Tertiary-butyl ether (TBA) in water and an optimization condition of trace analysis of MTBE and TBA using the design of experiment (DOE) was described. The aim of our research was to apply experimental design methodology in the optimization condition of trace analysis of fuel oxygenated compounds in soil-phase microextraction with GC/FID. The reactions of SPME were mathematically described as a function of parameters of Temp ($X_1$), Volume ($X_2$), Time ($X_3$) and Salt ($X_4$) being modeled by the use of the partial factorial designs, which was used for fitting 2nd order response surface models and was alternative to central composite designs. The model predicted agreed with the experimentally observed result ($Y_1$(MTBE, $R^2$ = 0.96, $Y_2$ (TBA, $R^2$ = 0.98)). The estimated ridge of the expected maximum responses and optimal conditions for MTBE and TBA were 278.13 and (Temp ($X_1$) = $48.40^{\circ}C$, Volume ($X_2$) = 73.04 mL, Time ($X_3$) = 11.51 min and Salt ($X_4$) = 12,50 mg/L), and 127.89 and (Temp ($X_1$) = $52.12^{\circ}C$, Volume ($X_2$) = 88.88mL, Time ($X_3$) = 65.40 min and Salt ($X_4$) = 12,50 mg/L), respectively.