• Title/Summary/Keyword: Solid-electrolyte

Search Result 702, Processing Time 0.028 seconds

Fabrication of Oxide Thin Films Using Nanoporous Substrates (나노기공성 기판을 사용한 산화물박막의 제조)

  • Park, Yong-Il;Prinz, Fritz B.
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.12 s.271
    • /
    • pp.900-906
    • /
    • 2004
  • Solid oxide fuel cells have a limitation in their low-temperature application due to the low ionic conductivity of electrolyte materials and difficulties in thin film formation on porous gas diffusion layer. These problems can be solved by improvement of ionic conductivity through controlled nanostructure of electrolyte and adopting nanoporous electrodes as substrates which have homogeneous submicron pore size and highly flattened surface. In this study, ultra-thin oxide films having submicron thickness without gas leakage are deposited on nanoporous substrates. By oxidation of metal thin films deposited onto nanoporous anodic alumina substrates with pore size of $20nm{\sim}200nm$ using dc-magnetron sputtering at room temperature, ultra-thin and dense ionic conducting oxide films with submicron thickness are realized. The specific material properties of the thin films including gas permeation, grain/gran boundaries formation, change of crystalline structure/microstructure by phase transition are investigated for optimization of ultra thin film deposition process.

Fabrication of Solid Electrolyte Oxygen Sensors Using $CaF_{2}$ and their Characteristics ($CaF_{2}$를 이용한 고체전해질 산소센서의 제조및 그 특성)

  • Lee, Jae-Hyun;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.40-49
    • /
    • 1994
  • Potentiometric cell oxygen sensors using $CaF_{2}$ were fabricated for monitering the oxygen partial pressure in the low temperature range ($300^{\circ}C{\sim}$500^{\circ}C). The disk type oxygen sensors consist of a reference electrode: Air($O_{2}:21%$)|Pt, a solid electrolyte $CaF_{2}$, and a sensing metel Pt electrode. And the change in open circuit emf of the disk type cell was about 45mV for the oxygen concentration range, $0.1%{\sim}10%$, at the cell temperature of $400^{\circ}C$. Also, the reference electrode incorporated type sensor showed the change of 40mV for 0.1% to 10% oxygen partial pressure range.

  • PDF

Thermodynamic Analysis of Solid Electrolyte $CO_2$ Sensor in Continuous and Discontinuous Flow Systems (연속 기체흐름계 및 일시 기체흐름계에서의 고체 전해질 $CO_2$ 가스센서의 열역학적 분석)

  • Choi, Soon-Don
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.319-326
    • /
    • 1998
  • Anodic half-reaction in the $Na^+$ ionic sensors using $Na_2CO_3$ and $MCO_3$ ($M=Cs_2,K_2,Li_2,Ca$) as a sensitive membrane is derived in continuous flow system to explain $CO_2$ sensing characteristics. For various gas-sensitive membranes, a well known overall reaction, $MCO_3\;=\;MO\;+\;CO_2$, cannot be applied for the EMF behaviors of these kinds of sensors. So, the anodic reaction is found to involve $Na_2CO_3$ and $M^{++}$-containing oxide phases by employing the ion exchange reaction at the interface of solid electrolyte and the sensitive membrane to maintain ionic balance in the whole cell. Based on the electrode reaction derived in flow system, differences of cell potentials between continuous and discontinuous flow systems were also discussed. These EMF differences were considerably caused by the partial pressures of oxygen and $CO_2$ as well as irreversible chemical reactions between electrode materials and $CO_2$ atmosphere.

  • PDF

Studies on the Development of the Automatic Blood Analyzer with Silicone Rubber-Based Solid-State $K^+$- and $Na^+$-Selective Electrodes (실리콘러버 지지체의 $K^+$$Na^+$ 선택성 고체형 전극을 이용한 자동혈액분석기의 개발에 대한 연구)

  • Kang, Myung-Sung;Jeon, Woo-Sung;Kim, Sun-Kwan;Kim, Dea-Hoon;Cha, Geun-Sig;Nam, Hak-Hyun;Cho, Han-Ik;Park, Sung-Sup
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.26-33
    • /
    • 1995
  • Silicone Rubber (SR)-based potassium- and sodium-selective solid-state electrodes have been developed for the portable blood electrolyte analyzer system. The electrochemical performance of these electrodes have been evaluated with a static experimental setup and with the newly developed blood electrolyte analyzer system (model; HS603). It has been shown that their potentiometric properties are essentially comparable to those of PVC-based ion-selective electrodes, but with greatly improved lifetime (200 and 40 days for potassium and sodium sensors, respectively) and potential stability (within $\pm0.1$ mV). Clinical tests have been performed with real serum samples and the results have been compared with those obtained from Ciba-Corning BGA 288 system; correlations were excellent, proving its practical utility as a new commercial system.

  • PDF

A Study on the PEM Electrolysis Characteristics Using Ti Mesh Coated with Electrocatalysts (Ti Mesh 처리 촉매전극을 이용한 고체고분자 전해질 전기분해 특성연구)

  • Sim, Kyu-Sung;Kim, Youn-Soon;Kim, Jong-Won;Han, Sang-Do
    • Journal of Hydrogen and New Energy
    • /
    • v.7 no.1
    • /
    • pp.29-37
    • /
    • 1996
  • Alkaline water electrolysis has been commercialized as the only large-scale method for a long time to produce hydrogen and the technology is superior to other methods such as photochemical, thermochemical water splitting, and thermal decomposition method in view of efficiency and related technical problem. However, such conventional electrolyzer do not have high electric efficiency and productivity to apply to large scale hydrogen production for energy or chemical feedstocks. Solid polymer electrolyte water electrolysis using a perfluorocation exchange membrane as an $H^+$ ion conductor is considered to be a promising method, because of capability for operating at high current densities and low cell voltages. So, this is a good technology for the storage of electricity generated by photovoltaic power plants, wind generators and other energy conversion systems. One of the most important R&D topics in electrolyser is how to minimize cell voltage and maximize current density in order to increase the productivity of the electrolyzer. A commercialized technology is the hot press method which the film type electrocatalyst is hot-pressed to soild polymer membrane in order to eliminate the contact resistance. Various technologies, electrocatalyst formed over Nafion membrane surface by means of nonelectrolytic plating process, porous sintered metal(titanium powder) or titanium mesh coated with electrocatalyst, have been studied for preparation of membrane-electrocatalyst composites. In this study some experiments have been conducted at a solid polymer electrolyte water electrolyzer, which consisted of single cell stack with an electrode area of $25cm^2$ in a unipolar arrangement using titanium mesh coated with electrocatalyst.

  • PDF

Preparation of Solid Polymer Electrolytes of PSf-co-PPSS/Heterooolyacid [HPA] Composite Membrane for Hydrogen Production via Water Elecrolysis (PSf-co-PPSS/HPA를 이용한 수소제조 수전해용 고체 고분자 전해질 복합 막의 제조)

  • Jung, Yun-Kyo;Lee, Hyuck-Jae;Jang, In-Young;Hwang, Gab-Jin;Bae, Ki-Kwang;Sim, Kyu-Sung;Kang, An-Soo
    • Journal of Hydrogen and New Energy
    • /
    • v.16 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • Proton conducting solid polymer electrolyte (SPE) membranes have been used in many energy technological applications such as water electolysis, fuel cells, redox-flow battery, and other electrochemical devices. The availability of stable membranes with good electrochemical characteristics as proton conductivity at high temperatures above 80 $^{\circ}C$ and low cost are very important for its applications. However, the presently available perfluorinated ionomers are not applicable because of high manufacturing cost and high temperature use to the decrease in the proton conductivity and mechanical strength. In order to make up for the weak points, the block copolymer (BPSf) of polysulfone and poly (phenylene sulfide sulfone) were synthesized and sulfonated. The electrolyte membranes were prepared with phosphotungstic acid (HPA)/sulfonated BPSf via solution blending. This study would be desirable to investigate the interaction between the HPA and sulfonated polysulfone. The results showed that the characteristics of SPSf/HPA blend membrane was a better than Nafion at high temperature, 100 $^{\circ}C$. These membranes proved to have a high proton conductivity, $6.29{\times}10-2$ S/cm, a water content, 23.9%, and a ion exchange capacity, 1.97 meq./g dry membrane. Moreover, some of the membranes kept their high thermal and mechanical stability.

The correlation between ionic conductivity and cell performance with various compositions of polymer electrolyte in dye-sensitized solar cells (염료감응형 태양전지에서의 고분자 전해질 종류에 따른 이온전도도와의 상호관계)

  • Cha, Si-Young;Kim, Su-Jin;Lee, Yong-Gun;Kang, Yong-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.306-308
    • /
    • 2007
  • Poly(ethylene glycol) dimethyl ether (PEGDME)/fumed silica/ 1-methyl -3-propylimidazolium iodide (MPII)/$I_2$ mixtures were used as polymer electrolytes in solid state dye-sensitized solar cells (DSSCs). The contents of MPII were changed and the concentration of $I_2$ was fixed at 0.1 mole% with respect to the MPII. The maximum ionic conductivity was obtained at [EG]:[MPII]:[$I_2$]=10:1.5:0.15. It was supposed that the maximum of ionic conductivities would match with that of cell efficiencies, if the ionic conductivity is a rate determining step in the sol id state DSSCs. However, the maximum composition did not show the maximum solar cell performance, indicating the mismatch between ionic conductivity and cell performance. This suggests that the ionic conductivity may not be the rate controlling step in determining the cell efficiency in these experimental conditions, whereas other parameters such as the electron recombination might play an important role. Thus, we tried to modify the surface of the $TiO_2$ particles by coating a thin metal oxide such as $Al_2O_3$ or $Nb_2O_5$ layer to prevent electron recombination. As a result, the maximum of the cell efficiency was shifted to that of the ionic conductivity. The peak shifts were also attempted to be explained by the diffusion coefficient and the lifetime of electrons in the $TiO_2$ layer.

  • PDF

Properties of Low Temperature Sintering of La0.8Sr0.2Ga0.8Mg0.2-xZnxO2.8 (X = 0.0 - 0.05) Electrolyte (La0.8Sr0.2Ga0.8Mg0.2-xZnxO2.8(X=0.0~0.05) 전해질의 저온 소결 특성)

  • Lim, Kyoung Tae;Lee, Chung Hwan;Yu, Ji Haeng;Peck, Dong-Hyun;Baik, Kyeong Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.3
    • /
    • pp.208-217
    • /
    • 2014
  • $La_{0.8}Sr_{0.2}Ga_{0.8}Mg_{0.2-x}Zn_xO_{2.8}$(LSGMZ, X=0-0.05) was prepared using a solid state reaction method. Two secondary phases ($LaSrGaO_4$ and $LaSrGa_3O_7$) of powders were identified by X-ray diffraction analysis. The relative amount of these secondary phases depended on the calcination conditions (temperature and time) and Zn content. The sintering density of LSGMZ was enhanced by increasing the Zn content and calcination temperature at the low sintering temperatures ($1250-1300^{\circ}C$). The relationship between the sintering density of LSGMZ and the synthesis conditions was discussed considering the phase analysis results.

Characterization of electrochemical behaviour for supercapacitor based on porous activated carbon composite with various contents of metal-organic framework(MOF) (금속유기골격체(Metal-organic Framework)의 함량에 따른 다공성 활성탄소 복합재료 기반 슈퍼커패시터의 전기화학적 거동 분석)

  • Jeong, Hyeon Taek;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1200-1207
    • /
    • 2020
  • We have fabricated the supercapacitor composed of porous activated carbon, metal-organic framework (MOF) with polymer based solid state electrolyte as a "ion gel" and characterized its electrochemical behaviour as a function of the MOF contents. The electrochemical properties of the supercapacitor were analyzed via cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and galvanostatic charge/discharge test. As a results, the supercapacitor based on porous activated carbon/MOF composite showed the highest capacitance value at 0.5 wt% of MOF contents and decreased capacitance with increase MOF contents over the 0.5 wt%. Consequently, the porous activated carbon/MOF composite based supercapacitor is applicable to various aspect for energy storage device.

Fabrication and Sensing Properties of NASICON Thick Film SO2 Gas Sensor Using Screen-print Method (스크린 인쇄법을 이용한 NASICON 후막 SO2가스 센서의 제조 및 특성)

  • Bae, J.C.;Lee, S.T.;Jun, H.K.;Bang, Y.I.;Lee, D.D.;Huh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.2
    • /
    • pp.115-119
    • /
    • 2003
  • The thick film type sensor having Pt/Na Super Ionic Conductor(NASICON) solid electrolyte/Pt/$Na_2$$SO_4$/Pt catalyst system for $SO_2$gas was fabricated by screen-print method. The phase of Na Super Ionic Conductor solid electrolyte sintered at different temperature of 1050, 1150,$ 1250^{\circ}C$ and for different time of 1.5, 2.5, 3.5 hr were investigated by XRD. The Electromotive Force variation of the sensor with $SO_2$concentrations and operating temperatures were investigated. The major phase of Na Super Ionic Conductor film sintered at 115$0^{\circ}C$ for 3.5 hr was sodium zirconium silicon phosphate($Na_3$Zr$_2$$Si_2$PO$_{12}$). The Nernst's slope of Na Super Ionic Conductor sensor for $SO_2$gas with the variation of concentration from 10 to 100 ppm was 167.14 ㎷/decade at the operating temperature of $500 ^{\circ}C$. The increase of oxygen partial pressure was not affected to the variation of Nernst's slope.e.