• Title/Summary/Keyword: Solid insulation material

Search Result 46, Processing Time 0.028 seconds

Comparative Study on Conductivity and Moisture Content Using Polarization and Depolarization Current (PDC) Test for HV Insulation

  • Jamail, N.A.M.;Piah, M.A.M.;Muhamad, N.A.;Kamarudin, Q.E.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • The Polarization and Depolarization Current (PDC) measurement is an efficient and effective diagnostic technique based on time domain measurement, for evaluating the high voltage insulation condition. This paper presents a review and comparison results from several published papers on the application of the PDC method to finding the conductivity and moisture content of various types of insulators. For solid insulation, the study was focused on cable insulation, electric machine stator insulation, and paper insulator in transformer insulation with different conditions. For liquid insulation, the review and comparison was done on biodegradable and mineral transformer oils, with fresh oil condition, and aged condition. The results from previous researchers tests were complied, analyzed and discussed, to evaluate the application of the PDC method to monitor the conductivity and moisture of HV equipment insulation systems. From the review results, the PDC technique successfully gives an indication of the conductivity and moisture level of high voltage insulation.

Characteristics of Surface Flashover on Partially Immersed of Spacer in Liquid Nitrogen (액체질소 중에서 spacer의 부분적 침적에 대한 연면 방전특성)

  • 김영석;이병성;백승명;정종만;정순용;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.2
    • /
    • pp.177-182
    • /
    • 2000
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconduction power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen(LN2). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in LN2, and last step is comparison the result of this research with that of fully immersed in LN2 and at cryogenic temperature gaseous nitrogen(GN2). This result presented that surface flashover voltage along solid spacer half immersed in LN2 was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10mm. In the case of t> 10mm, however, spacer flashover voltage was equal to that obtained in GN2 at cryogenic temperature. And the immersed direction functions as role of deciding the difference of surface flashover voltage.

  • PDF

Study of Thermal Conductivity and Mechanical Property of Elastic Epoxy (탄성형 에폭시의 열전도율 및 기계적 특성에 대한 연구)

  • Lee, Kwan-Woo;Lee, Kyoung-Yong;Choi, Yong-Sung;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.319-322
    • /
    • 2004
  • In this paper, we studied on the thermal conductivity and a mechanical property of the elastic epoxy. According to industrial development, insulation materials have various properties. They are solid, liquid, gas state, there are various type. Epoxy, a kind of insulation material, demand of not only high hardness but also elastic property. When the electric current flows into the conductor and the place where the heat occurs, this heat becomes the cause which shortens the life of the electrical appliance. Therefore, for the heat occurred transmit quickly, thermal conductivity of the insulation material is highly demanded. We studied on the thermal conductivity of elastic epoxy on the high voltage. In this result, thermal conductivity confirmed that it followed thermal property of mixed epoxy and addictives. Hardness is decreased when addictives increased.

  • PDF

Electrical characteristics of PET film for wire insulation of transformer in fluorocarbon (Fluorocarbon에서의 변압기권선 절연용 PET필름의 전기적 특성연구)

  • 허창수;이재복
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.483-489
    • /
    • 1996
  • Power transformer have many unsymmetrical structure and electric field is enhanced in that area. Those unsymmetrical area are not covered oftenly by solid insulating material which is used as a framework specially in gas transformer. By that result there is a possibility to decrease the total insulation class of the transformer. So in this study the electrical characteristic of $FC+SF_6$ mixture gas which is used as coolants for large power gas insulated transformer and its effects on electrical characteristics of structural material are investigated. Also breakdown characteristic with the tension of taping and curvature of the coil are studied which could be used as a design factor of large power transformer.

  • PDF

The Estimation of the Dielectric Strength Decrease of the Solid-solid Interfaces by using the Applied Voltage to Breakdown Time Characteristics

  • Shin, Cheol-Gi;Bae, Duck-Kweon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.278-282
    • /
    • 2007
  • In the complex insulation system that is used in extra high voltage(EHV) devices, according to the trend for electric power equipment of high capacity and reduction of its size, macro interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. In this paper, the dielectric strength decrease of the macro interfaces between epoxy and ethylene propylene diene terpolymer(EPDM) was estimated by using the applied voltage to breakdown time characteristics. Firstly, the AC short time dielectric strength of specimens was measured at room temperature. Then, the breakdown time was measured under the applied constant voltage which is 70% of short time breakdown voltage. With these processes, the life exponent n was determined by inverse power law, and the long time breakdown voltage can be evaluated. The best condition of the interface was LOS(low viscosity(350 cSt) silicone oil spread specimen). When 30 years last on the specimens, the breakdown voltage was estimated 44% of the short time breakdown voltage.

The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor (예방진단센서가 내장된 옥외용 ECT의 전계분포특성)

  • Lee, Han-Joo;Cho, Sung-Hoon;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joo;Kang, Sung-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

Angle Ring Press Board Characteristic in Accordance with Temperature and Humidity for High Voltage Transformer (온도와 습도에 따른 초고압 변압기용 앵글링 프레스보드 특성)

  • Suh, Wang Byuck
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.60-64
    • /
    • 2020
  • In this study, to develop angle ring pressboards for high voltage transformers, the radius and thickness are modified under the conditions of temperature and humidity. In particular, a pressboard with a thickness of 6 mm and a radius at the angled part were investigated based on the simulation of the principal stress from the angled optimization profile shape. As a result, by the appropriate application of a higher temperature, the solid insulation can be improved to reduce the moisture content for an optimized profile angle of a high voltage transformer. This also results in the improvement of the safety factor by 25%. It is determined that the electrical insulation properties of pressboards in high voltage transformers can be enhanced by improving their properties.

PD Characteristic of Electrical Tree Generated by Inside Void Defect (내부 보이드 결함에서 발생하는 전기트리의 부분방전 특성)

  • Park, Seong-Hee;Jung, Hae-Eun;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.334-335
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Development of 25.8kV class solid insulated switchgear (25.8kV 고체절연스위치기어 개발)

  • Lee, J.H.;Ma, J.H.;Yu, L.;Lee, J.G.;Won, S.Y.;Lee, S.W.;Kim, Y.G.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

The Relationship between Grain Design and Non-uniform Ablation of Solid Rocket Insulation (추진제 형상과 연소관 단열재 불균일 삭마의 관계)

  • Kim, Jeongjin;Lee, Jungseob;Jin, Jungkun;Lee, Dohyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.2
    • /
    • pp.28-34
    • /
    • 2020
  • In order to relieve the burden of the rear ablative material, the combustion test of the solid rocket motor with the forward deployed multi-pin grain design was successfully performed twice. However, after disassembling the solid rocket motor, a non-uniform ablation pattern was found in the rear ablative material. Periodic repetition of local and regional ablation was measured precisely. Two-dimensional flow and eddy flow, created by the uneven main-pin flow hitting the rear ablative material, were identified as the cause of non-uniform ablation. In addition. when the rear pins were removed, the possibility of securing the soundness of the rear ablative material was confirmed as the average flow velocity and the standard deviation were lowered.