• Title/Summary/Keyword: Solid Insulation

Search Result 144, Processing Time 0.029 seconds

Structural properties of the epoxy resin which adds the Nanofiller (Nanofiller를 첨가한 에폭시 수지의 구조적 특성)

  • Lee, Chang-Gong;Lee, Sung-Gap;Ahn, Byeong-Lib;Won, Woo-Sik;Woo, Hyoung-Gwan;Noh, Hyun-Ji
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1234-1235
    • /
    • 2008
  • To add Nanofiller in the epoxy which is used with the solid insulation material of existing and is a research which observes the improvement of the structural quality to produce the Nanocomposite. Montmorillonite uses with Nanofiller, MMT of the content expense (wt%) which is various and mixed an epoxide and produced sample. According to content of the sample result MMT according to respectively content expense to measure SEM photographing which is the possibility of knowing the minute structure of section with sample where is produced and the tensile strength will be able to observe the change of quality. MMT silicate layer uniformly more in the result and within epoxy matrix, being dispersed, will be able to observe.

  • PDF

A Study on Position and Induced Voltage of ADSS Using CSM (CSM을 이용한 ADSS유도전압 해석 및 위치선정에 관한 연구)

  • Myung, S.H.;Lee, B.Y.;Lee, G.C.;Lee, J.B.;Ha, T.H.;Joo, M.N.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1654-1656
    • /
    • 1997
  • Tracking currents related to field exposure for ADSS in T/L is of importance. At phase-ta-phase voltage in excess of 100 kV self-supporting aerial cables with solid insulation tend to suffer damage in regions close to the tower. The damage can be put down to surface tracking currents resulting from different degrees of surface contamination and moisture. Main characteristic of this exposure is the induced voltage analysis and position of ADSS. For complicated calculation of induced voltage on ADSS, this paper described an effective numerical calculation method based on CSM. The proposed methods are applied to 275 kV T/L of Malaysia.

  • PDF

An Isolated Bidirectional Modular Multilevel DC/DC Converter for Power Electronic Transformer Applications

  • Wang, Zhaohui;Zhang, Junming;Sheng, Kuang
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.861-871
    • /
    • 2016
  • With high penetration of renewable energies, power electronic transformers (PETs) will be one of the most important infrastructures in the future power delivery and management system. In this study, an isolated bidirectional modular multilevel DC/DC converter is proposed for PET applications. A modular multilevel structure is adopted as switching valves to sustain medium voltages to achieve modular design and high reliability. Only one high-frequency transformer is used in the proposed converter, which significantly simplifies the circuit and galvanic insulation design. A dual-phase-shift modulation strategy is proposed to regulate the output power and achieve a simple voltage balancing control. A down-scaled (2 kW/20 kHz) prototype is constructed to demonstrate the proposed converter and verify the control strategy. The experimental results comply with the theoretical analysis well, with the highest power efficiency reaching 97.6%.

A Measurement of Switching Surge Voltage using Voltage Type Inverter (전압형 인버터 스위칭 서지전압 측정)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.16-21
    • /
    • 2002
  • Most adjustable-speed drives(ASDs) designed to operate 220[V] induction motors incorporate voltage-source inverters (VSIs), which create motor voltages at high switching frequencies. The motor leads used to connect an ASD to a motor can behave like transmission lines for voltage pulses, which can be amplified (reflected) at the motor terminals. The resulting oscillatory transient, known as the long-lead effect, can stress and consequently degrade the statorinsulation system of a motor. This Brief describes the results of tests to 1) determine the correlation between peak motor voltage and the length of motor leads and 2) determine the correlation between peak motor voltage and the switching frequency of the ASD Insulation failures like this usually are caused by voltage surges. Voltage surges are often the result of switching power circuits, lightning strikes, capacitor discharges and solid-state power devices.

  • PDF

Prediction of Life-Time on the Macroscopic Interface between Solid Materials with Analysis of V-t Characteristics (V-t 특성 분석에 의한 고체 거시계면의 수명 평가)

  • 오재한;이경섭;배덕권;김충혁;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.607-611
    • /
    • 2000
  • The characteristics on the interface between Epoxy and EPDM which are materials of the underground insulation systems of power delivery have studied. The breakdown strength of specimens are observed by applying high AC voltage at the room temperature. The breakdown times under the constant voltage below the breakdown voltage were gained. As constant voltage is applied the breakdown time is proportion to the breakdown strength. The life exponent n is gained by inverse power law and the long breakdown life time can be evaluated. AC breakdown strength and life time is improved by oiling to the interface. When the low viscosity oil is spread interface has the highest life time.

  • PDF

Axisymmetric Finite Element Analysis of Decomposing Polymeric Composites and Structures (열경화성 고분자 복합재 구조물의 축대칭 유한요소해석)

  • Lee, Seon-Pyo
    • 연구논문집
    • /
    • s.24
    • /
    • pp.81-96
    • /
    • 1994
  • To investigate failure mechanisms observed in carbon-phenolic thermal insulators, differential equations which govern the decomposition process in a deformable anisotropic porous solid are derived for three-dimensional axisymmetric constructions. The governing equations not only couple the material deformation with pore pressure, but also couple pressure and temperature, which means that heat convected by the pyrolysis gases is properly accounted for. Then the Bubnov-Galerkin finite element method is applied to these equations to transform them into a semidescrete finite element system. A thermal insulation liner in the cowl region under typical operating conditions is analyzed to find a mechanism for plylift. The results from the structural analysis show across-ply failure in the cowl zone. The mechanism for plylift is hypothesized as a sequential procedure : 1) the across-ply failure which is the precursor to plylift and 2) the local fiber buckling caused by generation of excessive in-plane compressive stress. To prevent plylift, the across-ply stress can be reduced by using appropriate material ply angles in cowl zone design.

  • PDF

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened - (공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

Dielectric properties and microstructures of (CaxSr1-x)ZrO3 ceramics

  • Li, Yu-De;Chen, Jian-Ming;Lee, Ying-Chieh
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.6
    • /
    • pp.461-466
    • /
    • 2018
  • The effects of Ca/Sr ratio and the sintering temperature on the properties of $(Ca_xSr_{(1-x)})ZrO_3$ (CSZ) ceramics were investigated in this study. CSZ ceramics were prepared using solid-state reaction process, which were sintered in air at temperatures ranging from $1350^{\circ}C$ to $1450^{\circ}C$. Their structures were characterized by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM). The change in Ca/Sr ratio significantly affected the crystalline phase and the dielectric properties of the $(Ca_xSr_{(1-x)})ZrO_3$ ceramics. The secondary phase, $Ca_{0.15}Zr_{0.85}O_{1.85}$, was observed and increased correspondingly with the rising of sintering temperatures. In order to understand the effects of secondary phase on the dielectric properties of CSZ ceramics, the $Ca_{0.15}Zr_{0.85}O_{1.85}$ phase was prepared individually using solidstate method. The $Ca_{0.15}Zr_{0.85}O_{1.85}$ ceramics sintered at $1500^{\circ}C$ for 2 hours possessed a dielectric constant (${\varepsilon}_r$) of 21.7, a dielectric loss ($tan{\delta}$) of $49.510^{-4}$ and an Insulation Resistance (IR) of $2.1{\times}10^{10}{\Omega}$. The ($Ca_{0.7}Sr_{0.3})ZrO_3$ ceramics exhibited the best dielectric properties, with a permittivity of 29, a dielectric loss ($tan{\delta}$) of $2.7{\times}10^{-4}$, and an Insulation Resistance (IR) of $2.6{\times}10^{12}{\Omega}$.

An Experimental Study on the Charring Rate of Solid Sawn Timber Exposed to Fire (화재에 노출된 제재목의 탄화속도에 대한 실험적 연구)

  • Yeo, In-Hwan;Park, Kyung-Hoon;Cho, Kyung-Suk;Min, Byung-Yeol;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.78-84
    • /
    • 2011
  • In this study, we have measured the charring rate of solid sawn timber as a preceding step for develop performance based fire safety design method of wood framed building structures. The follows are the summary of fire test results carried out with $400{\times}400$ mm cross-section Douglas-fir in varied of thickness and grain directions. I) When the timber thickness increase under same dimension, the charring rate decreases gradually. It is seemed the charring layer up on a thickness roles as a insulation, gives combustion delaying time to specimen. 2) The charring rates measured at different depths (10, 20, 30, 40 mm) in timber which varying thickness (20, 40, 80, 120 mm) when exposed maximum 1 hour standard fire increase by 30 mm depth, but decrease at 40 mm. It is seemed the minimum charr layer should be 30 mm for having role of insulation. 3) The charring rate of cross section surface (direction of perpendicular to grain) was more high than that of grain direction. It can be explained by the cracks and gaps from greater charr contraction made more heat flux incident into timber.