• 제목/요약/키워드: Solar shade

검색결과 69건 처리시간 0.028초

Analysis of the Climate inside Multi-span Plastic Greenhouses under Different Shade Strategies and Wind Regimes

  • He, Keshi;Chen, Dayue;Sun, Lijuan;Huang, Zhenyu;Liu, Zhenglu
    • 원예과학기술지
    • /
    • 제32권4호
    • /
    • pp.473-483
    • /
    • 2014
  • In this work, the effects of shade combination, shade height and wind regime on greenhouse climate were quantified. A two-dimensional (2-D) computational fluid dynamics (CFD) model was developed based on an 11-span plastic greenhouse in eastern China for wind almost normal to the greenhouse orientation. The model was first validated with air temperature profiles measured in a compartmentalized greenhouse cultivated with mature lettuce (Lactuca sativa L., 'Yang Shan'). Next, the model was employed to investigate the effect of shade combinations on greenhouse microclimate patterns. Simulations showed similar airflow patterns in the greenhouse under different shade combinations. The temperature pattern was a consequence of convection and radiation transfer and was not significantly influenced by shade combination. The use of shade screens reduced air velocity by $0.02-0.20m{\cdot}s^{-1}$, lowered air temperature by $0.2-0.8^{\circ}C$ and raised the humidity level by 0.9-2.0% in the greenhouse. Moreover, it improved the interior climate homogeneity. The assessment of shade performance revealed that the external shade had good cooling and homogeneity performance and thus can be recommended. Furthermore, the effects of external shade height and wind regime on greenhouse climate parameters showed that external shade screens are suitable for installation within 1 m above roof level. They also demonstrated that, under external shade conditions, greenhouse temperature was reduced relative to unshaded conditions by $1.3^{\circ}C$ under a wind speed of $0.5m{\cdot}s^{-1}$, whereas it was reduced by merely $0.5^{\circ}C$ under a wind speed of $2.0m{\cdot}s^{-1}$. Therefore, external shading is more useful during periods of low wind speed.

Protective Measures From Solar Ultraviolet Radiation for Beach Lifeguards in Tuscany (Italy): Shade and Clothing Strategies

  • Daniele Grifoni;Giulio Betti;Andrea Bogi;Lucia Bramanti;Alessandra Chiarugi;Bernardo Gozzini;Marco Morabito;Francesco Picciolo;Francesco Sabatini;Lucia Miligi
    • Safety and Health at Work
    • /
    • 제13권4호
    • /
    • pp.421-428
    • /
    • 2022
  • Background: The exposure to solar ultraviolet radiation is a significant risk factor generally underestimated by outdoor workers and employers. Several studies have pointed out that occupational solar exposure increased eye and skin diseases with a considerable impact on the lives and productivity of affected workers. The main purpose of this study was to evaluate the effectiveness against ultraviolet radiation of some measures recently undertaken for the protection of lifeguards in a coastal area of Tuscany. Methods: Different shading structures (gazebos and beach umbrella) were tested during a sunny summer's day on a sandy beach by means of two radiometers; the UV protection offered by some T-shirts used by lifeguards was also tested in the laboratory with a spectrophotometer. Results: The analysed shading structures strongly reduced the ultraviolet radiation by up to 90%, however a not always negligible diffuse radiation is also present in the shade, requiring further protective measures (T-shirt, sunglasses, sunscreen, etc.); the tested T-shirts showed a very good-excellent protection according to the Australian/New Zealand standard. Conclusion: Results obtained in this study suggest how the adoption and dissemination of good practices, including those tested, could be particularly effective as a primary prevention for lifeguards who are subjected to very high levels of radiation for long periods.

담장허물기로 인한 주택지 외부공간의 열환경 평가 (Evaluation of Thermal Environment of External Space following the Fence Demolition Campaign in Detached Housing Area)

  • 류지원;정응호;시미즈 아키;오상학;호야노 아키라
    • 한국주거학회논문집
    • /
    • 제23권1호
    • /
    • pp.19-26
    • /
    • 2012
  • This study examines how fence demolition may change the thermal environments of external spaces of houses and suggests what factors need to be considered when a fence is demolished. The results of the research are summarized as follows. In terms of the surface temperature, there was no significant difference in all time plots after the removal of all materials. However, applying greening methods (changing the surface materials, planting trees, and building a green roof following fence demolition) could lower the surface temperatures, calling for proper plans for various greening methods. The MRT results indicates that walls block solar radiation and provide shade, reducing radiant heat from roads and surrounding structures during the daytime when solar radiation directly effects surface temperatures. Also, the application of greening methods such as planting vegetation and trees could have shading and evapotranspiration effects, leading to a lower temperature distribution. The HIP results were similar to the MRT results. They indicated that walls block solar radiation within the residential sections and provide shade, resulting in a lower temperature distribution during the daytime. However, areas where greening methods such as a green roof or tree planting were applied showed $1{\sim}2^{\circ}C$ difference in temperature distribution.

도심 수목이 분산형 주거 태양광에너지 잠재량에 미치는 영향 (The Effect of Urban Trees on Residential Solar Energy Potential)

  • 고예강
    • 한국조경학회지
    • /
    • 제42권1호
    • /
    • pp.41-49
    • /
    • 2014
  • 본 연구는 미국 샌프란시스코시 수목 음영이 개별 건물 지붕 및 옥상에 입사되는 태양에너지 잠재량에 미치는 영향을 LiDAR를 이용한 고해상도 3차원 수치모델을 이용하여 공간적으로 정량화하였다. 최근 분산형 태양광 발전이 기후변화 대응에 중요한 부분으로 주목받고 있으나, 이러한 도심 태양광 발전은 주변부의 지형, 건물, 지붕모양, 수목 등의 음영에 의해 발전량이 제한되는 특성이 있다. 특히 건물 주변의 수목의 경우 도시열섬현상의 저감, 냉난방 에너지 수요량의 절감 등의 순기능과 태양광 발전량 감소의 역기능을 동시에 가지고 있어 두 가지 효용의 상충을 최소화하기 위해 해당 위치에 대한 공간적 분석이 요구된다. 샌프란시스코시 전체 건물 지붕면적의 태양에너지 총량은 년간 18,326,671 MWh으로, 수목의 음영에 의한 감소량은 326,406 MWh로 총량의 1.78%에 해당하였다. 건물지붕의 단위 면적당 일조량은 $34.4kWh/m^2/year$에서 $1,348.4kWh/m^2/year$ 범위로 산출되었다. 본 연구를 통해 도심 수목에 의한 건물별 일조에너지 감소량의 공간자료가 구축되었으며, 개별 건물지붕에 일조량의 변이를 주변 수목의 밀도, 평균수고, 수고의 분산값을 이용한 회귀모델을 통해 설명하였다. 본 연구는 도심수목의 환경적 순기능을 유지함과 동시에 태양광 발전 감소량의 최소화 할 수 있는 방법을 제공함으로써 지속가능한 도시를 구축하는데 기여할 것으로 기대된다.

출력을 고려한 모듈 간 최적화 간격 (Module liver optimization interval that consider generating power)

  • 최대원;최홍규;이근무;심용식;최영준;장민기;김태훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.53-58
    • /
    • 2009
  • Solar photovoltaic power generation system is judging that by the most suitable new refreshing energy in real condition of our country forward continuously interest for solar photovoltaic power generation system and diffusion me enlarged. Output decline problem is item to consider necessarily and should be verified in continuous interest for solar photovoltaic power generation system are diffusion. Present plan that minimize output decline calculating module liver optimum interval that consider recitation of a poem to reduce output decline by module liver shade by incidence angle consideration and this that occupy most parts among factor because do output of solar photovoltaic power generation system well.

  • PDF

BIPV 시스템에서의 모듈 종류에 따른 건축적 특성 연구 - 채광형 시스템을 중심으로 - (A Study of the Architectural Characteristic Depending upon the Module in the BIPV System)

  • 이응직;이충식
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.196-202
    • /
    • 2008
  • Effective climate protection is a most important tasks of our time. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. In this study it was analyzed by the case study the function of the requirement of the BIPV-module as building material and this architectural characteristic according to the kind of the module. Therefore the goal of this study is to get securing the application information of BIPV as windowpane. BIPV modules are manufactured in the form of G/G. In the case of the crystal type the Transparent and the light Transmission is to be adjusted by the spacer attitude of the cell. Although this type could not be optimal for light effect of indoors because of the inequality of shade, the moving shade play makes a dramatic Roomimage by the run of sun. The application of this type would be for canopy, window or roof in the corridor or resounds. With amorphous the type it is to be manufactured simply largely laminar, and thus that will shorten building process. There is a relatively good economy to use and to the window system easily. After the production technology is easy the transparency of the modules to adjust, and the module shows to a high degree constant characteristics of light permeability and transparency. Without mottle of module shade is good the use for the window or roof glazing of office, library, classroom, etc. to adapt. The BIPV modules took generally speaking a function as building material to the daylight use, shading, isolation and also to the sight. That means that BIPV modules have as multifunctional system to sustainable architecture good successes and they are at the same time as Design element for architecture effectively.

  • PDF

도심 녹음수의 체감온도지수(WBGT) 조절효과 (The Effect of Urban Shade Trees on the WBGT(Wet Bulb Globe Thermometer Index))

  • 주민진;이춘석;류남형
    • 한국조경학회지
    • /
    • 제32권3호
    • /
    • pp.51-59
    • /
    • 2004
  • Focusing on WBGT(Wet Bulb Globe Thermometer Index) according to the LAI(Leaf Area Index) variation of trees, this study verifies the effects of urban shade trees on the outdoor thermal environment. As for methodology, air$.$globe temperature, air humidity and WBGT were measured under three shade trees whose LAIs were 2.1, 4.0 and 8.2 respectively at midday(12:00-13:00) of 14 sunny days from the 4th through the 29th day of September 2003. Those factors were also measured at the unshaded areas and compared with the values of shaded areas. The measured site was paved with interlocking concrete bricks. The measurements were analyzed through the ANCOV A(Analysis of Covariance) and the regression routines of SPSS11 for windows (SPSS Inc., 2001). The major findings were as follows. 1. The direct correlation between WBGT and LAI was very low. On the contrary, the WBGT showed close correlation with air$.$globe temperature and air humidity, and the LAI also showed very close correlation with globe temperature. These results tell that dominant shading effect by the tree is on the screening of direct solar radiation which lower the globe temperature and WBGT consequently. 2. While the average globe temperatures and WBGT at unshadowed area were 40.4$^{\circ}C$ and 26.2$^{\circ}C$ respectively, the former under the shade tree with LAI 2.1, 4.0 and 8.2 were 34.5$^{\circ}C$, 32.6$^{\circ}C$ and 30.2$^{\circ}C$, and the latter were 24.6$^{\circ}C$, 24$^{\circ}C$ and 23.4$^{\circ}C$ respectively. 3. The relationship between LAI(x) and WBGT(y) can be presented with the following equation: y = 24.23+1.53 $e^{-x}$+0.36x $e^{-x}$+0.46 $x^2$ $e^{-x}$ ($R^2$ =.98) =.98)

이중 진공관형 태양열 집열기의 집열관 내부 형상과 운전 조건이 성능 변화에 미치는 영향 (Effects of Absorber Tube Shape and Operating Conditions on Thermal Performance of All-Glass Evacuated Tube Solar Collectors)

  • 최은용;김용;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.19-25
    • /
    • 2005
  • All-glass evacuated tube solar collectors consist of glass evacuated tubes and absorber tubes. Solar thermal energy from the sun is transferred to the working fluid through the glass evacuated tube and the absorber tube. Several collectors which have different absorber tubes are tested to find the effects of the absorber tube shapes and the operating conditions such as the incident heat flux and the flow rate. As the results, the efficiency of the collector which has a finned tube U tube is about $2{\sim}5%$ higher than that of the others in all cases on an average. And the collector has a finned U tube has the highest efficiency at the high flow rate and the low incident heat flux. In this condition, the outlet mean temperature is low and the heat loss becomes small. Also, it is known that the fin effect is greater than the shade effect.

태양광 발전시스템의 부분그늘 보상을 위한 알고리즘에 관한 연구 (The Study on Algorithm for Partial shade Compasation of PV)

  • 고강훈;이현우;서기영;고희석;문성찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.271-274
    • /
    • 2003
  • In this paper, compare and analyze existent MPPT algorithms. Existent algorithms have defects which don't generate it in a partial shade or low insolation. Therefore, to supplement it, we design improved IncCond algorithm consisted of a Aux. switch and capacitor with Generation Control circuit which can always obtain maximum generation power at the factor which is reduced generational efficiency by partial shade. Generation Control circuit is method which can always get maximum output power as it regularly controls each voltage of serial connected solar cell. Accordingly, it can improve efficiency and confidence of utility interaction inverter. Construction of system use a low price PIC16F87X. We analyze special character according to system operation through simulation and prove the validity through experiments.

  • PDF