• 제목/요약/키워드: Solar radiation rate

검색결과 200건 처리시간 0.02초

낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 - (Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage -)

  • 김성락;조창범;김해동
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

멸치가공을 위한 태양열 온수기 개발 (A development of solar hot water system for anchovy proceeding)

  • 공태우;지명국;이용훈;정한식;정효민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.671-676
    • /
    • 2001
  • This study are development results of solar hot water system for anchovy proceeding. The heat amounts of boiling vessel are calculated 292.66W at forward and backward direction, and surface direction are calculated 373.14W. The polyenoic rate of anchovy are measured lower as high temperature, but monoenoic and polyacid are higher. Then the others. The maximum radiation of anchovy fishing grounds are shown $350kcal/m^2h$ at pm. 13:00, Chungdo in CHINA. Distributions of Velocity and temperature in boiling vessel are calculation. Solar collector and boiling vessel for anchovy proceeding ship are developed to automatic control system.

  • PDF

접시형 태양열 집광 시스템의 에너지 분포 특성에 관한 연구 (A Study on Energy Distributions Produced by Dish Solar Concentrating System)

  • 현성택;강용혁;천원기
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.907-913
    • /
    • 2002
  • An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17 m with a maximum energy density of 1.89 MW/$m^2$. By evaluating the position of flux centroid, it was found that there are errors within 2 cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius. The area concentration ratio normalized to 800 W/$m^2$ insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.

2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성 (Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan)

  • 전병일;오인보
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

열교환코일 내장형 태양열 축열조의 성능향상 (제2보 시뮬레이션) (Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 2 : Simulation))

  • 김종현;이용걸;이욱재;홍희기
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.361-366
    • /
    • 2016
  • As an alternative of well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and verified a superior thermal stratification in a tank, which results in increased collector efficiency and solar fraction. But the phenomenon of temperature reversal was often experimentally observed in the tank, so a revised control was successfully applied which is to heat only lower coil using three way valve if temperature reversal occurs and to operate the collector with low flow rate when the condition of solar radiation is not good. In the present study, using TRNSYS we compared the existing lower heating and the proposed lower and upper heating with a control preventing temperature reversal. The results showed that the proposed method has an increase of collector efficiency by 5.1% and solar fraction by 3.2%.

태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구 (Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector)

  • 우종수;최광환;윤정인
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향 (Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season)

  • 이재한;박동금;권준국;엄영철;최영하
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.60-64
    • /
    • 2000
  • 여름철 시설내 온도강하를 위해 차광, 포그, 미스트, Fan and Pad 등 다양한 방법들이 행해지고 있고 그 효과에 대해서도 잘 알려져 있다. 그러나 대부분의 효과가 처리방법간 일 최고 기온시의 상대적인 비교를 나타낸 것이므로 실제로 일평균, 순평균하게 되면 그효과는 미미하게 된다. 더구나 우리나라는 8월중 맑은날이 10일 미만이고 상대습도가 놀기 때문에 기화냉각 효과는 더욱 떨어지게 된다. 따라서 여름철 토마토 재배시 온도강하 방법으로 포그처리는 냉방효파에 비해 설치 및 유지관리비에 많은비용이 소요되는 문제가 있고, 온도제어 차광은 지나치게 차광되어 수량감소가 많아 부적합하므로 팬+일사제어 자동차광으로 외기온 가까이 온도를 내리는 것을 목표로 하는 것이 경제적일 것으로 생각된다.

  • PDF

Design and Performance Analysis of Conical Solar Concentrator

  • Na, Mun Soo;Hwang, Joon Yeal;Hwang, Seong Geun;Lee, Joo Hee;Lee, Gwi Hyun
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.21-29
    • /
    • 2018
  • Purpose: The objective of this study is to evaluate the performance of the conical solar concentrator (CSC) system, whose design is focused on increasing its collecting efficiency by determining the optimal conical angle through a theoretical study. Methods: The design and thermal performance analysis of a solar concentrator system based on a $45^{\circ}$ conical concentrator were conducted utilizing different mass flow rates. For an accurate comparison of these flow rates, three equivalent systems were tested under the same operating conditions, such as the incident direct solar radiation, and ambient and inlet temperatures. In order to minimize heat loss, the optimal double tube absorber length was selected by considering the law of reflection. A series of experiments utilizing water as operating fluid and two-axis solar tracking systems were performed under a clear or cloudless sky. Results: The analysis results of the CSC system according to varying mass flow rates showed that the collecting efficiency tended to increase as the flow rate increased. However, the collecting efficiency decreased as the flow rate increased beyond the optimal value. In order to optimize the collecting efficiency, the conical angle, which is a design factor of CSC, was selected to be $45^{\circ}$ because its use theoretically yielded a low heat loss. The collecting efficiency was observed to be lowest at 0.03 kg/s and highest at 0.06 kg/s. All efficiencies were reduced over time because of variations in ambient and inlet temperatures throughout the day. The maximum efficiency calculated at an optimum flow rate of 0.06 kg/s was 85%, which is higher than those of the other flow rates. Conclusions: It was reasonable to set the conical angle and mass flow rate to achieve the maximum CSC system efficiency in this study at $45^{\circ}$ and 0.06 kg/s, respectively.

우리별 1호에서의 SPACE RADIATION 환경 조사 (CRE ECPERIMENT OF KITSAT-1)

  • 신영훈;민경욱;최영완;김성헌
    • Journal of Astronomy and Space Sciences
    • /
    • 제11권1호
    • /
    • pp.131-145
    • /
    • 1994
  • Cosmic Ray Experiment (CRE)는 KITSAT-1 의 여 러 module 중 하나로 Total D Dose Experiment (TDE) 와 Cosmic Particle Experiment (CPE) 두개의 sub-system 으로 구성되어 있다. CRE 의 목적은 KITSAT-1 궤도에서의 우주 환경을 조사하는 것이다. KITSAT-1 의 궤도는 inner Van Allen belt에 위치하며, 이 지역 에셔는 고에너지 proton들이 많이 분포하고 있어 위성체에 단기적인 또는 장기적인 radiation 효과를 미치고 있다. 1년여의 설험 결과로부터 Van Allen belt가 무척 안정되어 있고 태양의 활동이 CPE,TDE 및 SEU (Single Event Upset) rate 에 영향을 줌을 알 수 있었다. 또한 CREME code 에 의해 예상됐던 것보다 많은 고에너지 입자 flux가 관찰되었다.

  • PDF

지역 구분을 통한 약식 BIPV 발전량 예측 모델 개발 (The Simplified Pre-Estimation Model Development of a BIPV Generation Rate by the District Division)

  • 최원기;오민석;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.19-29
    • /
    • 2016
  • Whilst there are growing interests in pursuing energy efficiency and zero-energy buildings in built environment, it is widely recognised that Building-Integrated Photovoltaic (BIPV) is one of the most promising and required technologies to achieve these goals in recent years. Although BIPV is a broadly utilized technique in variety of fields in built environments, it is required that generation of BIVP should be analysed and calculated by external specialists. The aim of this research is to focus on developing a new diagram for prediction of the pre-estimation model in early design stage to harness solar radiation data, PV types, slopes, azimuth and so forth. The results of this study show as follows: 1) We analysed 162 districts in a national level and the examined areas were categorised into five zones. The standard deviation of the results was 2.9 per cent; 2) The increased value of solar radiation on a vertical plane in five categorised zones was 42kWh/m3, and the result was similar to the average value of 43.8kWh/m3; and 3) The pre-estimation of diagram was developed based on the categorisation of zones and azimuth as well as the results of the developed diagram showed little difference compared to the previously utilised method. The suggested diagram in this paper will contribute to estimate BIPV without any external contribution to calculate the value. Even though the result of this study shows little difference, it is required to investigate a number of different variables such as BIPV types, modules, slope angle and so forth in order to develop an integrated pre-estimation diagram.