Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 2 : Simulation)  

Kim, Jong-Hyun (Department of Mechanical Engineering, Graduate School of Kyung Hee University)
Li, LongJie (Department of Mechanical Engineering, Graduate School of Kyung Hee University)
Lee, Uk-Jae (Department of Mechanical Engineering, Graduate School of Kyung Hee University)
Hong, Hiki (Department of Mechanical Engineering, Kyung Hee University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.28, no.9, 2016 , pp. 361-366 More about this Journal
Abstract
As an alternative of well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and verified a superior thermal stratification in a tank, which results in increased collector efficiency and solar fraction. But the phenomenon of temperature reversal was often experimentally observed in the tank, so a revised control was successfully applied which is to heat only lower coil using three way valve if temperature reversal occurs and to operate the collector with low flow rate when the condition of solar radiation is not good. In the present study, using TRNSYS we compared the existing lower heating and the proposed lower and upper heating with a control preventing temperature reversal. The results showed that the proposed method has an increase of collector efficiency by 5.1% and solar fraction by 3.2%.
Keywords
3-way valve; Collector efficiency; Solar fraction; Temperature reversal; TRNSYS; Variable flowrate control;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Hong, H., 2004, 3% Use of alternative energy in 2006 and solar thermal system, Magazine of the SAREK, Vol. 33, No. 11, pp. 47-54.
2 Dincer, I. and Rosen, M. A., 2002, Thermal Energy Storage-Systems and Application, John Wiley & Sons, New York, pp. 95-122.
3 Kim, J. H., Choi, B. S., Hong, H., and Kim, Y. S., 2005, Experimental verification for a spiral-jacketed storage tank applied to solar thermal system, Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 4, pp. 341-346.
4 Kwon, J. W. and Hong, H., 2012, Enhancement of stratification for solar water storage tank with spiral jacket and coil (Part 1 : Verification experiment), Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 24, No. 4, pp. 250-252.
5 Lee, U. J. and Hong, H., 2015, Performance enhancement of solar thermal storage tank with heat exchange coils(Part 1 : Verification experiment), Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 27, No. 4, pp. 213-219.   DOI
6 Cardinale, N., Piccininni, F., and Stefanizzi, P., 2003, Economic optimization of low-flow solar domestic hot water plants, Journal of the Renewable Energy, Vol. 28, No. 12, pp. 1899-1914.   DOI