• 제목/요약/키워드: Solar panel. Energy

검색결과 166건 처리시간 0.024초

30kW 고정식 태양광발전시스템의 발전 특성 조사 (Power Survey of 30kW Solar System without tracking mechanism)

  • 문채주;임정민;장영학;소순열;최병천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1126-1127
    • /
    • 2008
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system used infinity of solar energy, cost of fuel is needless and there in no air pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 30[kW] large scale applications installed in Mokpo National University dormitory roof. The status of photovoltaic system components, are inter-connection and safety equipment monitoring system will be summarized as this article. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory. In this paper represent 30[kW] utility photovoltaic system examination result.

  • PDF

아파트 입면형 PV적용방식의 발전성능효과해석 연구 (A simulation analysis of PV application method effect on electric power performance in an apartment wall facade)

  • 서정훈;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.25-32
    • /
    • 2006
  • The objective of this study is to investigate the effect of building integrated PV application method on power generation. PV modules were integrated to a hypothetical apartment building facade in Seoul, Korea. Three different design options of PV panel mounted on exterior wall were developed for the analysis of cooling effects through ventilation. Numerical simulations using TRNSYS coupled with COMIS were executed to evaluate the design options. Their facade configurations are such as vertically installed PV panels with or without air gap between PV rear surface and exterior wall surface, and the tilted PV panels attached to the exterior wall at an angle of to the horizontal. Parametric results show that there is little difference regardless of the air 9ap width between PV rear surface and exterior wall surface. Special strategies which could effectively cool a PV panel to increase the electric power are required if we prefer to a vertical facade configuration in a building integrated PV installation. Consequently, it is expected that there is no reason for architect to install vertically PV panels with air gap unless active strategies are considered.

과학기술위성 2호 태양전지판의 환경시험 규격에 대한 고찰 (Analysis on Environmental Test Specifications for Solar Panels of STSAT-2)

  • 장태성;김홍배;우성현;이상현;남명룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.957-961
    • /
    • 2005
  • A satellite component must withstand vibration caused when launch vehicle acoustics and engine rumble transfer to it through its structural mount. Components shall be subjected to environmental tests after manufacturing process thus the environmental test conditions are needed for component level test including vibration and shock. This paper deals with derivation of component-level environmental test specifications, especially for solar panels of STSAT-2(Science & Technology SATellite-2). Sine sweep random vibration, and shock test conditions were generated for solar panels by assuming the satellite as single-degree-of-freedom system with a base excitation.

  • PDF

계절적 변화에 따른 $TiO_2$ 염료감응형 태양전지의 발전 성능 분석 (Performance Analysis of the $TiO_2$ Dye-Sensitized Solar Cell according to Seasonal Changes)

  • 문병은;최은규;김종구;유영선;윤용철;김현태
    • 생물환경조절학회지
    • /
    • 제23권3호
    • /
    • pp.221-228
    • /
    • 2014
  • 본 연구는 염료감응형 태양전지를 이용하여 시간에 따른 일사량과 그에 따른 전력량의 분석을 통해 계절적 변화에 따른 온실 적용 염료감응형 태양전지의 효율에 관한 기초 자료 수집 및 분석을 목표로 하였다. 경상대학교 소재 온실 근처(위도 $35^{\circ}$ 9' 9.20" N, 경도 $128^{\circ}$ 5' 44.90" E, 고도 52m)에 태양전지 어레이를 설치, 2012년 8월, 10월, 11월, 2013년 2월 약 네 달 동안 태양전지가 받는 일사량과 그에 따른 전력량을 측정 및 비교, 분석하였다. 10월의 태양전지 패널 면적에 따른 일사량이 약 1,013.03MJ, 발생된 전력량은 약 4.87kWh로 네 달 중 가장 높게 측정되었고, 11월의 패널 면적에 따른 일사량이 약 755.25MJ, 발생 전력량은 약 3.34kWh로 가장 낮게 측정되었다. 염료감응형 태양전지의 평균 효율의 경우 8월 한 달간, 약 3.12%로 측정되었고, 10월 2.60%, 11월 2.39%, 2월 2.23%로 각각 측정되었다. 본 연구를 통해, 향후 염료감응형 태양전지의 온실 등 농업분야 적용 시 기초자료로 활용 할 수 있을 것으로 기대된다.

The Development Measuring System of Temperature Effect to Produce Electric Power of Solar Cell

  • Sadmai, Ong-art
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.104-113
    • /
    • 2015
  • This paper focuses on a temperature effects on a PV panel which has been installed in Thailand. The main objective is cleaning PV panels and reduce temperature of PV panel by water injects from waterway and experimental results of PV power what it is difference. This project is designed by PLC control system which water injects and control PV temperature, In addition, this project consists of hardware and software such as water pump, water injection and PLC control has been automatically and it can be control system manually. The automatic control system is working when PV temperature rises up over 45 degree Celsius after that the pumping machine would inject water to the surface of PV panels and it must be stop when the PV panel temperature comes down less than 45 degree Celsius. The result of actual experimental found that the control system has been done correctly under specify condition. The experimental has been shown electrical data before and after water injects on PV system found that the electrical power a bit increases and The energy has been taken from PV panel less than energy consumption equipment of control system which taken to operate the water injecting system.

염료감응형 태양전지를 적용한 유리 패널의 효율 향상에 관한 연구 (A Study on the Efficiency Improvement of Glazing Panel with DSC Modules)

  • 장한빈;강준구;이상길;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.35-41
    • /
    • 2013
  • Dye-sensitized solar cell (DSC) allows light transmission and the application of various colors that make it especially suitable for building-integrated PV (BIPV) application. In order to apply DSC module into windows, it has to be panelized: DSC module should be protected with reinforced glass to the entire surface. Up to date, it seems to be common to make double glazing with DSC modules with air gaps between the glasses and the DSC modules. Few research has been conducted on the characteristics of various glazing types with DSC modules. This study aims to analyze the electrical performance of DSC modules according to panelizing method for glazing unit with DSC modules. The prototype of the DSC glazing that applied silicone filler between DSC modules and glasses was developed. The electrical performances of this type of DSC glazing with the filler and rather conventional double glazing with DSC modules were compared. Their performances were measured using a solar simulator that is suitable for DSC performance testing. The results indicated that the electrical performance of the filler type DSC glazing improved by 7% compared to that of the conventional DSC double glazing type.

영농형 태양광 발전 솔라쉐어링에 따른 하부 일사량 변화의 해석 및 분석 (Simulation and Analysis of Solar Radiation Change Resulted from Solar-sharing for Agricultural Solar Photovoltaic System)

  • 이상익;최진용;성승준;이승재;이지민;최원
    • 한국농공학회논문집
    • /
    • 제62권5호
    • /
    • pp.63-72
    • /
    • 2020
  • Solar-sharing, which is an agricultural photovoltaic system installing solar panels on the upper part of crop growing field, has especially drawn attention. Because paddy fields for cultivating crops are large flat areas, there have been various attempts to utilize solar energy for solar photovoltaic as well as growth of crops in agriculture. Solar-sharing was first proposed in Japan, and has been actively studied for optimization and practical uses. The domestic climate differs from the climate conditions in which the solar-sharing has been widely studied, therefore, it is required to develop the solar-sharing technology suitable for the domestic climate. In this study, a simulation model was developed to analyze the change of solar radiation resulted from the solar-sharing installation. Monthly solar illumination intensity and the change of illumination intensity according to the various conditions of solar panel installation were simulated. The results of monthly illumination analysis differed by altitude of the sun, which was related to season. In addition, it was analyzed that the monthly illumination decreased by up to 42% due to solar-sharing. Accordingly, it is recommended that solar-sharing should be installed as a way to maximize the efficiency of solar photovoltaic system while minimizing the decrease in solar radiation reaching the crops.

태양광패널을 이용한 Awning 시스템에 관한 연구 (A study on the solar panel-powered Awning system)

  • 정재훈;박원현;이동헌;최명훈;김민;김현조;조윤재;이원상;김송현;이형기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.743-744
    • /
    • 2016
  • 현재 그린에너지로 부상하고 있는 태양광발전으로 인하여 많은 시설의 전력을 태양광으로 대체함으로 많은 에너지 및 공해 및 환경오염 요소를 줄여나가고 있다. 지금도 많은 연구가 되고 있으며 각종 응용분야에 접목을 시도하고 있다. 본 논문에서는 태양광 패널을 간판과 융합하여 낮에는 에너지를 생성하고 밤에는 간판 역할을 함으로 간판에 사용되는 에너지를 보다 절약 할 수 있는 장점을 가진다 또한 낮 시간때에는 천막과 같은 역할을 함과 동시에 에너지를 발전함으로 사용 용도가 높을 것으로 예상된다.

  • PDF

태양전지모듈 후면의 냉각조건에 따른 조립식 건축자재와 일체화에 관한 연구 (A Study on the Integrated Prefab Building Materials Depending on the Cooling Type of PV Mocdule Backside)

  • 이소미;이용호;홍성민
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.9-15
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, the purpose of this research is to integrated prefab building materials depending on the cooling type of PV modules. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module temperature. From the basis of these results on the correlation of temperature and irradiation were obtained.

  • PDF

ENERGY ANALYSIS UTILIZING BIM FOR ZERO NET ENERGY TEST HOME

  • Cho, Yong K.
    • 한국BIM학회 논문집
    • /
    • 제2권2호
    • /
    • pp.17-26
    • /
    • 2012
  • This paper presents the results of a theoretical energy analysis of a research test bed called the Zero Net Energy Test House (ZNETH) in Omaha, Nebraska in U.S.A. The ZNETH project is being designed and built with the goal of consuming a negligible amount of energy by offsetting remaining usage after energy conservation. The theoretically consumed and generated energy levels were analyzed using energy modeling software programs. By integrating a highly graphical and intuitive analysis with a Building Information Model(BIM) of the house, this investigation introduces strategies to include sustainable materials and systems to predict energy generation with a case study of ZNETH. In addition, this paper introduces parametric analyses for better envelope design and construction material selection by analyzing simulated energy consumption with various parametric inputs, e.g., material types, location, and size. It was found that the current design of ZNETH does not meet its goal of zero net energy. Sugeestions are presented to assist ZHETH in meeting its net zero energy goal.