• Title/Summary/Keyword: Solar Photovoltaic Energy

Search Result 1,271, Processing Time 0.029 seconds

Low Temperature Deposition of Microcrystalline Silicon Thin Films for Solar Cells (태양전지용 미세결정 실리콘 박막의 저온 증착)

  • Lee, J.C.;Yoo, J.S.;Kang, K.H.;Kim, S.K.;Yoon, K.H.;Song, J.;Park, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1555-1558
    • /
    • 2002
  • This paper presents deposition and characterizations of microcrystalline silicon(${\mu}c$-Si:H) films prepared by hot wire chemical vapor deposition at substrate temperature below $300^{\circ}C$. The $SiH_4$ Concentration$[F(SiH_4)/F(SiH_4)+F(H_2)]$ is critical parameter for the formation of Si films with microcrystalline phase. At 6% of silane concentration, deposited intrinsic ${\mu}c$-Si:H films shows sufficiently low dark conductivity and high photo sensitivity for solar cell applications. P-type ${\mu}c$-S:H films deposited by Hot-Wire CVD also shows good electrical properties by varying the rate of $B_2H_6$ to $SiH_4$ gas. The solar cells with structure of Al/nip ${\mu}c$-Si:H/TCO/glass was fabricated with sing1e chamber Hot-Wire CVD. About 3% solar efficiency was obtained and applicability of HWCVD for thin film solar cells was proven in this research.

  • PDF

A Detailed Survey of Solar Energy Resources in East-North Asia Areas Using a Satellite (Focused on the Analysis of Chinese Areas) (인공위성을 이용한 동북아시아 지역의 태양광자원 정밀조사 (중국지역 분석을 중심으로))

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.95-105
    • /
    • 2007
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the solar radiation data. The works presented here is the analysis of solar radiation data for East-North Asia areas. The data utilized in the analysis consist of the global radiation on horizontal surface, measured at 2 different stations during 3 years for the period from 2002 to 2004 and estimated using satellite at 27 different stations over the China and Mongolia. Also the measured data has been collected at 16 different stations all of the South Korea and estimated using satellite at 12 different stations over the North Korea from 1982 to 2005. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is $3.57\;MJ/m^2$. We conclude, based on the analysis, that East-North Asia areas have sufficient solar energy resources for the photovoltaic power generation system.

A Study on the Photovoltaic Module Layout Considering the Azimuth and Inclination in Region (방위각 및 경사각을 고려한 지역별 태양광 모듈 배치안 검토)

  • Park, Sung-Hyun;Seo, Jang-Hoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.461-466
    • /
    • 2012
  • Recently, building energy systems with solar collector and solar module have increased to improve energy problem, a heat island, a global warming and carbon dioxide emissions. In this study, value of solar radiation in areas was analyzed using TRNSYS simulation, and the optimum tilt and orientation angle for installing a photovoltaic module was examined. Average values of the weather data in the past twenty years in areas were used as input data. The results show that the tilt angle of a photovoltaic module for gaining the annual maximum solar radiation varies in different localities, and values of the annual solar radiation gained by using the variable photovoltaic module increased by 2.5 percent as compared with that gained by using the fixed photovoltaic module. When fixed photovoltaic module is installed, it should be examined the tilt and orientation angle for installing a photovoltaic module was examined.

Forecasting the Grid Parity of Solar Photovoltaic Energy Using Two Factor Learning Curve Model (2요인 학습곡선 모형을 이용한 한국의 태양광 발전 그리드패리티 예측)

  • Park, Sung-Joon;Lee, Deok Joo;Kim, Kyung-Taek
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.441-449
    • /
    • 2012
  • Solar PV(photovoltaic) is paid great attention to as a possible renewable energy source to overcome recent global energy crisis. However to be a viable alternative energy source compared with fossil fuel, its market competitiveness should be attained. Grid parity is one of effective measure of market competitiveness of renewable energy. In this paper, we forecast the grid parity timing of solar PV energy in Korea using two factor learning curve model. Two factors considered in the present model are production capacity and technological improvement. As a result, it is forecasted that the grid parity will be achieved in 2019 in Korea.

Status of Photovoltaics in the world (세계 태양광발전산업 현황)

  • Kang, Gi-Hwan;Lee, Chang-Koo;Park, Kyung-Eun;Kim, Hyun-Il;Yu, Kwon-Jong;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.314-319
    • /
    • 2009
  • The photovoltaic(PV) industry has been growing worldwide. Recently, the PV industries not also in the traditional PV advanced countries but also in other countries are rapidly growing. Especially, China has become the largest supplier in the world PV supply side since 2007. Both the world PV supply and demand rose steadily in 2008 like recent bumper years. In 2008, the world solar cell production reached 6.85GW~7.91GW presenting growth of 85% over the previous year. On the demand side, 81 countries contributed to the 5.95GW presenting growth of 110% over the previous year.

  • PDF

Life Cycle Cost Analysis about Renewable Energy Facilities Combination of Photovoltaic system, Solar thermal system and Geothermal system (태양광발전, 태양열 급탕, 지열시스템의 신재생에너지설비 조합에 관한 LCC 분석)

  • Chun, Sang Hyun;Ahn, Jang-Won;Kim, Wonwoo;Cho, Seung-Yun
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.105-112
    • /
    • 2012
  • When a building is planned and designed, the design should be able to minimize the cost during the whole life cycle of the building. This study has begun to analyze LCC about the alternative design which is applicable to renewable energy facility construction. It is reviewed domestic and foreign papers about the trend of LCC technology and it is determined the analytical method to analyze the LCC of renewable energy. Regarding the review of alternatives, it is chosen the three alternatives which are able to designed combing the renewable energy facilities and it is performed the LCC analysis about each alternative. Alternative 1 is Photovoltaic + Solar Thermal + Photovoltaic /Wind Power, Alternative 2 is Geothermal + Photovoltaic, and Alternative 3 is Photovoltaic + Solar Thermal. The LCC analysis is present value method, its analytical period is 40 years and it is applied 3.2% of real discount rate. As a result, it is proved that Alternative 1 and Alternative 3 are not able to collectible the early investment cost during the analytical period and Alternative 2 is analyzed that its pay-back period of early investment cost is about 31 years. As the final outcome of this study on case analysis, it is more advantageous to use the combination of Geothermal and Photovoltaic energy than to use the other combination in LCC aspect.

The Assessment of Payback Period for the Photovoltaic System in Residential Building (주거용 건물의 태양광 발전시스템 투자회수 기간 산정)

  • Kim, Myung-Chul;Ju, Jai-Wook;Seo, Gan-Ho;Lee, Kyung-Hee;Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.87-93
    • /
    • 2007
  • The demand for solar electric power systems, namely, photovoltaic system has grown steadily in our country over the last 10 years. However, the main obstacle against using photovoltaic system is the financial viability especially concerned with initial cost. The other factors affecting the economic viability of photovoltaic system are cost of electric energy, amount of electric energy produced by the photovoltaic system, discount rate, energy cost escalation rate, inflation rate, project life, and so on. Therefore, this thesis studies on the effect of various relating factors on economic evaluation of photovoltaic system in residential building by calculating payback period.

Case Study on 12kW Building Integrated Photovoltaic System (12kW급 건물일체형 태양광발전시스템 사례분석)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;So, Jung-Hoon;Yu, Gwon-Jong;Kim, Jun-Tae;Lee, Kil-Song
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.

Hail Impact Analysis of Photovoltaic Module using IEC Test (IEC 우박시험에 대한 태양광모듈 충돌 해석)

  • Park, Jung-Jae;Park, Chi-Yong;Ryu, Jae-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.4
    • /
    • pp.23-33
    • /
    • 2020
  • The loss in photovoltaic power due to hailstorms has been highlighted as a major issue in the sustained growth of the PV power plant industry. This study investigates the safety of a solar module by conducting a numerical analysis of a hail test according to the IEC 61215 standard. Our study aims to elucidate the detailed behavior between the ice and solar modules and the micro-cracks forming on solar modules during hailstorms. To analyze the impact of hail, we used the ANSYS AUTODYN software to evaluate the impact characteristics on a solar module with different front glass thicknesses. The simulations show that a solar module with a glass thickness of 4.0 mm results in excellent durability against hail. The results indicate the feasibility of using simulations to analyze and predict micro-cracks on solar modules tailored to various conditions, which can be used to develop new solar modules.

Transition of Isc according to Natural Solar Spectrum on c-Si and a-Si PV Module (결정질과 비정질 PV모듈의 자연광 스펙트럼에 따른 Isc의 변화)

  • Kong, Ji-Hyun;Ji, Yang-Geun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.86-91
    • /
    • 2009
  • In this paper, we analyze the Transition of Isc by natural solar spectrum of c-Si and a-Si PV module. Commonly, performance of photovoltaic (PV) module is estimated under the standard test condition (STC). That is, solar irradiance $1kW/m^2$, solar spectrum distribution: AM1 5G, module temperature $25^{\circ}C$ This means it rarely meets actual outdoor conditions. The solar spectrum always changes. So it is rare to fit the standard solar spectrum AM1 5G defined in ASTM G173-03 or IEC 60904-3. Thus spectral response of PV module is different depending on the material. so we estimated the variation of Isc at every minutes by comparing c-Si PV module with a-si PV module for outdoor conditions.

  • PDF