• 제목/요약/키워드: Solar Blind

검색결과 59건 처리시간 0.028초

블라인드형 외부차양의 종류 및 반사율에 따른 건물에너지 저감효과 분석 (An Analysis on Building Energy Reduction Effect of Exterior Venetian Blind According to Orientation and Reflectance of Slat)

  • 김진아;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.28-34
    • /
    • 2013
  • It is essential to reduce building energy consumption in office building because government enact policy which encourages building energy certification from 2013. Office building has high cooling energy demand due to large glazed area of facade in these days. Shading devices can be an alternative of reducing high cooling energy demand. So, this study simulated a variety of exterior venetian blinds to know how much building energy be affected by orientation and reflectance of slat. The results of this study are based on Seoul weather data. The following is a summary of this study. 1) As a slat of venetian blinds has the lower reflectance, the more building energy reduced. Reflectance is usually affected by color and material of slat. In case reflectance is 0.2 reduce 4% of building energy than reflectance is 0.8. 2) Horizontal exterior venetian blinds are more effective than vertical exterior venetian blinds in all of orientation. Horizontal shape is average 16% more effective in shading effect than vertical shape. 3) In this case study, the most effective shading device is low reflectance horizontal exterior venetian blinds that result about 18% building energy reduction than no shade model. The results of this research can be used to plan shading devices for energy conservative office building.

염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석 (Analysis of Properties of UV Corona on Insulator in Salt Water Environments)

  • 김영석;최명일;김종민;방선배;송길목;이명준;이우창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구 (Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds)

  • 조원화;임남기
    • 한국건축시공학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 2010
  • 본 연구에서는 전열해석 프로그램인 피지벨(PHYSIBEL)을 사용하여 블라인드 내장형 창호시스템의 일사차단성능 및 단열성능에 따른 에너지 성능을 평가하였다. 피지벨 해석시 창호별 구성 재료의 열적특성과 해석조건을 결정하기 위해서 Mock-up시험을 실시하였으며, 컴퓨터 시뮬레이션을 통한 결과를 바탕으로 공동주택 기준층 1개 세대(33평형)를 대상으로 연간에너지 소비특성, 연간전열량, 연간 냉난방 비용을 분석하였다. 실험결과, 연간전열량은 일반 창호시스템 대비 블라인드 내장형 창호시스템에서 블라인드를 올린 경우 냉방시 10%, 난방시 11% 절감할 수 있으며, 블라인드를 내린 경우 냉방시 25%, 난방시 30%정도를 절감할 수 있는 것으로 나타났다. 블라인드 내장형 창호시스템의 냉 난방 부하 절감량은 일반 창호시스템에 비해 냉방시 283.3KWh, 난방시 76.3KWh 로 냉 난방 에너지 절감효과는 단위세대당 359.6KWh 절감시킬 수 있는 것으로 나타났으며, 이것은 단위세대당 연간 에너지원단위(TOE) 약 0.078toe, 이산화탄소톤($tCO_2$) $0.16tCO_2$을 절감시킬 수 있어 온실가스 저감에도 유리할 것으로 판단된다. 또한, 블라인드 내장형 창호시스템의 냉 난방비용 절감액은 일반창호시스템과 비교하여 연간 냉방비용 10만원, 난방비용 5만원으로 연간 냉 난방 비용을 약 15만원 정도 절감시킬 수 있는 것으로 나타났다.

대규모 해상풍력발전단지의 안전관리를 위한 법적 사각지대 분석 및 개선 제안 (Analysis of the Legal Blind Sectors of the Large-Scale Offshore Wind Farms of Korea and Proposal to Improve Safety Management)

  • 김인철;남동
    • 해양환경안전학회지
    • /
    • 제29권2호
    • /
    • pp.127-138
    • /
    • 2023
  • 국제사회는 글로벌 기후위기 극복을 위해 2050년까지 탄소중립(Net Zero)을 목표로 다양한 탈탄소 에너지원 개발을 지속하고 있다. 우리 정부에서도 '재생에너지 3020' 정책을 수립하고 태양광이나 풍력을 이용한 에너지 개발계획을 추진함에 따라 해상 풍력발전단지와 같이 연안해역에서 기존에는 볼 수 없었던 대규모 해양개발사업이 추진되고 있다. 해양시설물은 선박의 입장에서 볼 때는 항행 장애물의 일종이며, 해양시설물 설치에 따라 좁아진 수역에서 선박 간 충돌사고 발생 또는 선박과 해양시설물의 접촉사고 발생시 환경오염 및 인명피해 등의 발생이 우려된다. 이에 국내외의 해상풍력발전단지 개발계획을 살펴보고 풍력단지에서 선박의 안전한 통항을 보장하기 위한 제도적 장치가 완비되어 있는지 분석하였으며, 해외의 입법 사례와 국내 법규를 비교하여 법적 사각지대를 해소하기 위한 새로운 법령안을 제안함으로써 대한민국의 관할해역에서 해양시설물의 안전한 운영과 선박의 안전한 통항을 기대하였다.

1차원적 단순배열구조 재귀반사체의 반사출력광 특성 및 응용 (Analysis and Application of the Reflection Characteristics of a Simple Retro-reflector)

  • 정용범;홍성훈;이승걸;오범환
    • 한국광학회지
    • /
    • 제25권5호
    • /
    • pp.239-244
    • /
    • 2014
  • 재귀반사체(Retro Reflector)는 그 특별한 기능을 살려 도로 교통안전, 특수 블라인드, 광소자 resonator 등 다양한 분야에서 활용 영역이 넓어져 가고 있다. 특히 근래에는 '재귀반사구조체'를 창문의 차양 및 채광 구조물로서 도입하여 조명을 스마트화하는 경우도 제시되고 있다. 이에 본 연구는, 태양광 조절용 구조물로서, 띠구조를 1차원적으로 단순배열한 '주름판형-재귀반사체', St-RR(Strap type-Retro Reflector) 구조를 정의하고, 입사각도에 따라 그 반사광의 특성을 분석하였다. 또한, 이 특성 결과를 용이하게 파악할 수 있도록 시각화한 특성 도표를 고안하였고, 이를 이용하여 각종 태양광 조절 구조물을 보다 정량적으로 설계할 수 있음을 보였다.

GaN를 이용한 Schottky diode형 자외선 수광소자의 제작 (Fabrication of a Schottky Type Ultraviolet Photodetector Using GaN Layer)

  • 성익중;이석헌;이채향;이용현;이정희;함성호
    • 전자공학회논문지D
    • /
    • 제36D권6호
    • /
    • pp.28-34
    • /
    • 1999
  • 본 논문에서는 GaN 박막 위에 각각 알루미늄(Al)과 백금(Pt)을 증착하여 저항성 전극 및 투명한 schottky 전극을 형성한 평면형 자외선 수광소자를 제작하였다. 제작된 소자에 대해 전기적 특성과 광학적 특성을 조사하여 자외선 센서로서의 적합성을 검토하였다. 사파이어 기판위에 성장된 GaN 박막은 $7.8{\times}10^{16}cm^{-3}$의 도핑(doping)농도와 $138 cm^2/V{\cdot}s$의 이동도(mobility)를 가졌으며, 파장이 365 nm 이하인 빛만을 흡수하는 자외선 감지막 특성을 나타내었다. 5 V의 역방향 전압을 인가하였을 때 제조된 schottky형 자외선 센서는 325 nm의 자외선 파장에서 응답도가 2.84 A/W였고, $4{\times}10^4$의 큰 신호대 잡음비(SNR)의 $3.5{\times}10^9$W의 잡음등가전력(NEP)을 나타내었다. 따라서 이들 결과로부터 GuN를 이용한 schottky 다이오드가 가시광 차단 UV photodetector를 제조할 수 있음을 확인하였다.

  • PDF

반도체 & 디스플레이 업종에서 사용되는 독성가스 저감시설의 처리효율 측정방법에 관한 연구 (A Study on the Destruction or Removal Efficiency of Toxic Gas Reduction Facilities in Semiconductor and Display Industries)

  • 장성수;한재국;조현일;이수경
    • 한국가스학회지
    • /
    • 제21권6호
    • /
    • pp.88-95
    • /
    • 2017
  • 국내에서 독성가스의 사용은 반도체, 디스플레이 및 태양광 등 첨단산업의 발전에 따라 증가하고 있는 추세이다. 최근 5년간 국내 독성가스 소비량 현황을 살펴보면 연평균 12% 정도 증가 추세에 있지만, 아직까지 사용에만 관심이 집중되고 있고, 사후 처리나 안전에는 다소 소홀한 것이 사실이다. 2012년 9월 발생한 구미 불산 누출사고는 이러한 안전관리 부재를 단적으로 보여주는 사례이다. 이 사고로 인하여 정부, 업계 및 학계에서는 화학물질(독성가스) 누출사고 등에 대한 관심을 갖게 되었고, 정부 주도로 화학물질안전관리대책 등이 수립되어 추진되어 왔지만 아직까지 안전관리 사각지대가 많은 실정이다. 본 연구에서는 반도체, 디스플레이 업종에서 사용되는 저감설비에서 배출되는 가스상 물질에 대한 처리효율에 대한 효과적인 측정방법을 개발하는 것이 목적이다. 국립환경과학원과 UNFCCC에서 제시하는 반도체 & 디스플레이 업종에서 사용되는 온실가스 저감시설의 처리효율 측정방법 가이드라인에 대해 실증시험을 통해 맹독성가스 시설에도 오차 범위 내에서 적용 가능한지를 살펴보고 맹독성가스 저감시설에 대한 차별화된 효율성 측정 방법을 제시하였고, 독성가스 사고에 대한 선제적 예방을 위해서 독성가스 저감시설 등 안전설비에 대한 제3자 인증제도 도입의 필요성을 제안하였다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향 (Pergola's Shading Effects on the Thermal Comfort Index in the Summer Middays)

  • 류남형;이춘석
    • 한국조경학회지
    • /
    • 제41권6호
    • /
    • pp.52-61
    • /
    • 2013
  • 본 연구는 여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향을 파악하고자 수행하였다. 이를 위해 여름철 차양 및 겨울철 방풍을 고려하여 갈대발로 천개면 등을 차폐한 3가지 유형의 그늘시렁(가로 4m${\times}$세로 4m${\times}$높이 2.7m) I(천개면 차폐) II(천개면, 서향면 차폐) III(천개면, 서향면, 북향면 차폐)을 4층 옥상에 구축하였다. 그리고 1차 실험은 2013년 8월 14일부터 16일까지 대조구, 그늘시렁 I, III을 대상으로, 2차 실험은 2013년 8월 26일부터 28일까지 대조구, 그늘시렁 I, II를 대상으로 기상변수(기온, 습도, 복사, 풍속)를 측정하였다. 그늘시렁의 차양이 인체가 흡수하는 복사환경과 $T_{mrt}$$SET^*$에 미치는 영향은 다음과 같다. 그늘시렁의 차양으로 인해 인체가 흡수한 복사량의 저감은 단파복사가 장파복사에 비해 훨씬 크게 나타났다. 대조구 대비 인체가 흡수한 단파복사량 차이의 최댓값 ${\Delta}K_{abs,max}$는 그늘시렁 I과 III에서는 $-119W/m^2$$-158W/m^2$였으며, 그늘시렁 I과 II에서는 $-145W/m^2$$-159W/m^2$였다. 대조구 대비 인체가 흡수한 장파복사량의 차이의 최댓값 ${\Delta}L_{abs,max}$는 그늘시렁 I과 III에서는 $-15W/m^2$$-17W/m^2$였으며, 그늘시렁 I과 II에서는 $-8W/m^2$$-7W/m^2$였다. 그늘시렁의 차양에 의해 인체가 흡수한 $T_{mrt}$$SET^*$ 값도 낮아졌다. $T_{mrt}$는 1차 실험에서는 그늘시렁 I과 III에서 각각 최대 $16.0^{\circ}C$$21.4^{\circ}C$, 그리고 2차 실험에서는 그늘시렁 I과 II에서 각각 최대 $18.8^{\circ}C$$20.8^{\circ}C$ 저감되었다. $SET^*$는 1차 실험에서는 그늘시렁 I과 III에서 각각 최대 $2.9^{\circ}C$$2.6^{\circ}C$ 그리고 2차 실험에서는 그늘시렁 I과 II에서 각각 최대 $3.5^{\circ}C$$2.6^{\circ}C$ 저감되었다. 대조구 $SET^*$ 대비 그늘시렁 II, III의 $SET^*$ 저감효율은 그늘시렁 I에 비해 낮게 나타났는데, 이는 풍속의 차이 때문이었다. 따라서 그늘시렁 수직면의 차폐시에는 차양 못지않게 통풍을 고려하는 것이 필수적이라 생각된다. 대조구의 3일간 평균 최고기온이 $37.5^{\circ}C$였던 1차 실험기간 결과에서는 $SET^*$ 값이 하루 중 대부분 시간대에서 온열 쾌적대 및 수용대의 상한 값인 $28.7^{\circ}C$$30.4^{\circ}C$를 초과하였다. 반면에 대조구의 3일간 평균 최고기온이 $34.4^{\circ}C$였던 2차 실험결과, $SET^*$ 값이 그늘시렁 I에서는 18~12시와 오후 14~18시, 그늘시렁 II는 15~18시에만 온열 쾌적대에 드는 것으로 나타났다. 반면에 그늘시렁 I, II에서 $SET^*$ 값은 하루 중 대부분 시간대에서 온열 수용대에 드는 것으로 나타났다. 따라서 혹서기에 그늘시렁의 온열쾌적성을 확보하기 위해서는 갈대발 등에 의한 차양뿐만 아니라, 덩굴식물이나 녹음수에 의한 차양을 도입하는 방안을 강구하여야 할 것이다. 그리고 그늘시렁의 차양효과를 평가하는 지표로서 $T_{mrt}$$SET^*$는 실효성이 있었다고 판단되며, 향후 옥외 조경공간의 온열환경 평가 지표로서 활용이 기대된다.