• Title/Summary/Keyword: Soil corrosivity

Search Result 6, Processing Time 0.024 seconds

The Corrosivity Evaluations on Soil Surrounding the Buried Steel Piles under Manufacturing Plants (플랜트 하부의 강파일 인접 토양의 부식성 평가)

  • Jung, Sungwon;Park, Kyeong-Wan;Jeon, Jae-Young
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • The corrosivity evaluations on soil surrounding the buried steel piles under manufacturing plants. It was proven that the soil structure of this sample area is composed of several soil layers, and that each layer show the different corrosivity. The predicted average corrosion rates of some layers are about 0.33mm/y, which is over than the general corrosion rate, 0.01-0.02mm/y.

  • PDF

Antimicrobial and Other Properties of a New Stabilized Alkaline Glutaraldehyde Disinfectant/Sterilizer (병원에서 사용하는 수술도구 살균제, glutaraldehyde 용액의 살균 효과에 관하여)

  • 궁리환
    • YAKHAK HOEJI
    • /
    • v.31 no.4
    • /
    • pp.236-251
    • /
    • 1987
  • The chemistry, antimicrobial properties, organic soil resistance, toxicity, corrosivity and chemical stability of stabilized alkaline 2%, glutaraldehyde solution(SGS) are discussed. SGS retains the maximum antimicrobial activity of alkaline glutaraldehyde solutions and the chemical stability here to fore observed only with acidic glutaraldehyde solutions. These improvements, along with the inherent resistance of glutaradehyde to neutralization by organic soil, allow SGS to be continuously used for 14 days in situations of high dilution, or 28 days in situations of low dilution.

  • PDF

Assessment of external corrosion deterioration of large diameter metallic water pipes buried in reclaimed land (간척지대에 매설된 대구경 금속관의 외면 부식손상 평가)

  • Lee, Ho-Min;Choi, Tae-Ho;Kim, Jung-Hyun;Bae, Cheol-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.373-383
    • /
    • 2020
  • The purpose of this study was to evaluate the corrosion damage of large diameter metallic pipes buried in reclaimed land due to the corrosion effect by soil, and to propose a method of installing metal pipes in the reclaimed land. The results are as follow. First, the soil of the reclaimed land was gray clay, the soil specific resistance indicating soil corrosiveness was at least 120 Ω-cm, the pH was weakly acidic(5.04 to 5.60), the redox potential was at least 62 mV, the moisture content was at most 48.8%, and chlorine ions and sulfate ions were up to 4,706.1 mg/kg and 420 mg/kg. Therefore, the overall soil corrosivity score was up to 19, and the external corrosion effect seems to be very large. Second, the condition of straight part of pipes was in good condition, but most of KP joints were affected by corrosion at a severe level. The reason for this seems to be that KP joints accelerated corrosion due to stress and crevice corrosion in addition to galvanic corrosion in the same environment. Third, as a result of evaluating correlations of each item that affects the corrosion on the external part, the lower the soil resistivity and redox potential, the greater the effect on the KP joints corrosion, and the moisture content, chloride ion, and sulfate ion, the higher the value, the greater the effect on the corrosion of KP joints. In addition, among soil corrosion items, the coefficient of determination of soil resistivity with corrosion of KP joints was the highest with 0.6439~0.7672. Fourth, when installing metal pipes or other accessories because the soil of the reclaimed land is highly corrosive, it is necessary to apply a corrosion preventive method to extend the life of pipes and prevent leakage accidents caused by corrosion damage to the joint.

The characteristics of leachate migration and corrosivity in municipal wastefills at seaside (해안 도시폐기물 매립지의 침출수 이동 특성 및 부식성)

  • Jang, Yeon-Su;Jeong, Ha-Ik;Kim, Jin-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.12a
    • /
    • pp.33-66
    • /
    • 1992
  • Recently, waste landfills built on seashores have been increased because of the easy availability of broad area near the urban communities. To evaluate the performance of the marine clay landfill liner numerical contaminant transport analyses are performed by selecting the typical section of a waste landfill built on seashores and using hydraulic conductivity data obtained from the site. Also, the laboratory electrical resistivity test and the in-situ corrosion test are performed in order to analyze the influence of the soil and leachates composing the landfills on the construct ion materials. From the results of contaminant transport analyses, it is shown that the leachates can be migrated faster through narrow pervious channels than the wide homogeneous pervious tedium and the importance of good quality barriers to prevent the contaminant migration is recognized. In the laboratory electrical resistivity test all the earth materials except the cover soils saturated with distilled water have small resistivities, which shows a high potential of corrosivity of soils composing landfills. However, the degree of corrosion of specimens buried in the landfills was not so severe except the zinc and carbon steel specimens. This apparently conflict results present the necessity of the investigation of other major factors and the long term in-situ corrosion test.

  • PDF

Assessment of External and Internal Corrosion Growth Rate for Metallic Water Pipes (상수도 금속관의 외면과 내면 부식속도 평가에 관한 연구)

  • Bae, Chulho;Kim, Juhwan;Kim, Jeonghyun;Hong, Seongho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.1
    • /
    • pp.17-25
    • /
    • 2008
  • In this study, external and internal pit growth rate model and external non-linear regression corrosion model were proposed by measuring pit depths and evaluating various soil factors known to contribute to the corrosion for metallic water pipes. Average pit depths of external and internal for metallic water pipes were measured 1.38 mm and 2.13 mm, and internal pit growth rate also fasted twice than external pit growth rate. This means the corrosion potential of water quality was higher than soil. The corelation between external corrosion rate and each soil corrosion factor was low. However, proposed external non-linear regression corrosion model considering all soil corrosion factors showed a little higher correlation ($R^2=0.46$) than conventional model.

  • PDF

A Study on the Corrosivity according to Soil Characteristics and Electrolytic Protection for the Materials of Fuel Gas Pipe (토양 특성 및 전기방식에 따른 연료 가스용 강관의 부식 차이에 관한 연구)

  • Yim, Sang-Sik;Kim, Ji-sun;Ryu, Young-don;Lee, Jin-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.16-22
    • /
    • 2016
  • Coating pipe(PLP) has been generally used in buried site for protecting the corrosion. To prevent the damage by occurring the defect, other construction or execution works, an anti-oxidation environment was forcibly made by using protective potential. Coating and protective potential are applied simultaneously, but corrosion rate or defects are not easy to observe because soil composition has many uncertainty. Also, defect of coating pipe can not be directly observed. A corrosion coupon can easily measure a corrosion rate directly. The corrosion rate was measured with 6 scenarios using corrosion coupon during about 1 year(6 scenarios are based on soil type and protective potential or not in this research. Resultingly, the corrosion coupon has not occurred in the case of protected by potential current, but corrosion has occurred in a non-protected site. The corrosion rate was measured at least in the clay, and the propensity of corrosion rate was similar in other soil(sand and loams). The local corrosion has occurred in the clay because of high water content. On the other hand, general corrosion was occurred in sand and loams. Commonly, sand is not to corrosive soil. Although, corrosion occurred in sand can be estimated by chemical component and valid with chemical analysis report.