전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템 (Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit)

  • 한근우;김성곤;이충훈;최명현;정영국;임영철
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

A Novel Ripple-Reduced DC-DC Converter

  • Tao, Yu;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.396-402
    • /
    • 2009
  • A DC/DC converter generally needs to work under high switching frequency when used as an adjustable power supply to reduce the size of magnetic elements such as inductors, transformers and capacitors, but with the rising of the switch frequency, the switch losses will increase and the efficiency will reduce. Recently, to solve these problems, research is actively being done on a soft switching method that can be applied under high frequency and on a PWM converter that can be applied under low frequency such as a multi-level topology. In this paper a novel DC-DC conversion method for reducing the ripple of output voltage is proposed. In the proposed converter, buck converters are connected in series to generate the output voltage. By using this method, the ripple of output voltage can be reduced compared to a conventional buck converter. Particularly when output voltage is low, the number of acting switching elements is less and the result of ripple reduction is more obvious. It is expected that the converter proposed in this paper could be very useful in the case of wide-range output voltage.

로스레스 스너버를 사용한 고효율의 대용량 AC-DC 강압형 컨버터 (The High Power AC-DC Buck Converter of High Efficienty Using Loss-Less Snubber)

  • 문상필;서기영;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.951-954
    • /
    • 1998
  • This paper proposed that a high power AC-DC buck converter topology of high efficiency using loss-less snubber operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative resutls on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source of rresonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

멀티레벨 스위칭 회로를 이용한 트렌스리스형 계통 연계 인버터의 동작 특성 (Operation Characteristic of Transless type Grid-connected Inverter using Multi-level Switching circuit)

  • 김주용;노쾌협;정태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.916-917
    • /
    • 2008
  • In this paper, Switching damage of switches that is used to proposed power conversion system is reduced by soft switching way. dissipation by part resonance and my resonance stress for resonance of resonance circuit are decreased. Is acted by conversion system high effectiveness. Have following characteristic. Design snubber circuit that is used by switch protection in existent hard work rate Topology by resonant circuit for sogt switching, circuit structure was simple and control system is easy. Also, Can generate free output voltage by multi level Tuesday of output that use individuation Power Cell's Phase Shift PWM, and Low-end switching frequency the harmonic is few.

  • PDF

폴리머 표면측정을 위한 AFM 팁의 나노스케일 접촉-진동 해석 (Nanoscale Vibro-Contact Analysis of AFM Tip on Polymer Surface)

  • 이수일
    • 대한기계학회논문집A
    • /
    • 제30권2호
    • /
    • pp.135-140
    • /
    • 2006
  • In tapping mode atomic force microscopy (TM-AFM), the vibro-contact response of a resonating tip is used to measure the nanoscale topology and other properties of a sample surface. However, the nonlinear tipsurface interactions can affect the tip response and destabilize the tapping mode control. Especially it is difficult to obtain a good scanned image of high adhesion surfaces such as polymers and biomolecules using conventional tapping mode control. In this study, theoretical and experimental investigations are made on the nonlinear dynamics and control of TM-AFM. Also we report the surface adhesion is an additional important parameter to determine the control stability of TM-AFM. In addition, we proved that it was adequate to use Johnson-Kendall-Roberts (JKR) contact model to obtain a reasonable tapping response in AFM for the soft and high adhesion samples.

플라즈마 디스플레이 채널을 위한 단일 소프트-스위칭 다단계 에너지 회수 회로 드라이버 (Single Soft-Switching Multi-Level Energy Recovery Circuit Driver for Plasma Display Panel)

  • 하꼬보 아기용;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2006
  • The power source of an AC-PDP fur sustainer circuit is operated in high-voltage and high frequency switching during the process required to achieve the gas discharge current to generate light in a PDP panel. Since PDP has the characteristics of a pure capacitive load, the displacement current that occurs during charge and discharge generates considerable reactive power. An auxiliary circuitry called Energy Recovery Circuit (ERC) reduces the capacitive displacement current. However, this auxiliary topology also bears high stress in its components. In this paper, a multilevel voltage wave shaping sustainer circuit with auxiliary ERC characteristics for an AC-PDP driver is proposed. A comparative analysis and experimental results are presented.

  • PDF

Sinewave-PWM ZVS Inverter using High-Frequency Transformer for Utility AC Voltage Link

  • Chandhaket S.;Ogura K.;Konishi Y.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.511-515
    • /
    • 2003
  • This paper presents a novel prototype of the utility-interfaced sinusoidal pulse width modulated (SPWM) inverter using the high-frequency flyback transformer fur the small-scale solar photo-voltaic power conditioner (1kW - 4kW). The proposed SPWM power conditioner circuit with a high-frequency link has a function of electrical isolation, which is vital fur solar photovoltaic power conditioner systems with the viewpoint of safety and convenience. The discontinuous conduction mode (DCM) operation of the flyback transformer is also maintained to simplify the topology of the inverter circuit and control scheme. First, the operating principle of the proposed circuit is described far the understanding of the circuit parameters establishment. Then, the digitally constructed SPWM control scheme is presented. The proposed circuit is verified by the computer simulation and the prototype experiment.

  • PDF

Isolated Boost Converter with Bidirectional Operation for Supercapacitor Applications

  • Hernandez, Juan C.;Mira, Maria C.;Sen, Gokhan;Thomsen, Ole C.;Andersen, Michael A.E.
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.507-515
    • /
    • 2013
  • This paper presents an isolated bidirectional dc/dc converter based on primary parallel isolated boost converter (PPIBC). This topology is an efficient solution in low voltage high power applications due to its ability to handle high currents in the low voltage side. In this paper, the converter has been modeled using non-ideal components and operated without any additional circuitry for startup using a digital soft-start procedure. Simulated and measured loop gains have been compared for the validity of the model. On-the-fly current direction change has been achieved with a prototype interconnecting two battery banks. A second prototype has been constructed and tested for supercapacitor operation in constant power charge mode.

Current-Doubler 정류방식을 적용한 ZVS 비대칭 하프브리지 컨버터에 관한 연구 (A study on asymmetric Half-Bridge converter with Current-Doubler rectifier)

  • 이대혁;김용;배진용;권순도;이규훈;조규만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.169-172
    • /
    • 2004
  • This paper presents the Asymmetric Half-Bridge converter using current-doubler rectifier. Resonant conditions of the asymmetrical soft switching Half-Bridge converter is analyzed. Current-doubler converter has small voltage and current ripple. The comparison of topology compared to the secondary rectification for center-tap type and current-doubler type are discussed. Experimental result are obtained on a 5V, 20A DC/DC Half-Bridge converter MOSFET based prototype for the 100W.

  • PDF

단일전력단으로 구성된 AC/DC 풀 브리지 컨버터에 관한 연구 (A Study on AC/DC Full Bridge Converter With Single Stage Circuit)

  • 안병무;김용;김필수;임남혁;장성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1296-1299
    • /
    • 2000
  • A single stage AC/DC converter based on a full bridge topology suitable for high frequency soft switching converter applications is proposed. The proposed converter has high power factor, zero voltage switching, low noise and high efficiency. A pulse width modulation control is employed to reduce the switching and rectification losses respectively. This proposal converter has simple structure and low cost, The modelling and detailed analysis are performed to derive the design equations, a prototype converter has been designed and experimented. The new converter is attractive for high-voltage, high-power applications where IGBT's are predominantly used as the power switches. The principle of operation, features, and design are verified on a 1.5kW, 30kHz, IGBT based experimental circuit.