• Title/Summary/Keyword: Soft tissue perfusion

Search Result 26, Processing Time 0.019 seconds

Effect of Calvarial Cell Inoculated Onto the Biodegradable Barrier Membrane on the Bone Regeneration (흡수성 차폐막에 접목된 두개관골세포의 골조직 재생에 미치는 영향)

  • Yu, Bu-Young;Lee, Man-Sup;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.483-509
    • /
    • 1999
  • Biodegradable barrier membrane has been demonstrated to have guided bone regeneration capacity on the animal study. The purpose of this study is to evaluate the effects of cultured calvarial cell inoculated on the biodegradable barrier membrane for the regeneration of the artificial bone defect. In this experiment 35 Sprague-Dawley male rats(mean BW 150gm) were used. 30 rats were divided into 3 groups. In group I, defects were covered periosteum without membrane. In group II, defects were repaired using biodegradable barrier membrane. In group III, the defects were repaired using biodegradable barrier membrane seeded with cultured calvarial cell. Every surgical procedure were performed under the general anesthesia by using with intravenous injection of Pentobarbital sodium(30mg/Kg). After anesthesia, 5 rats were sacrificed by decapitation to obtain the calvaria for bone cell culture. Calvarial cells were cultured with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. The number of cell inoculated on the membrane were $1{\times}10^6$ Cells/ml. The membrane were inserted on the artificial bone defect after 3 days of culture. A single 3-mm diameter full-thickness artificial calvarial defect was made in each animal by using with bone trephine drill. After the every surgical intervention of animal, all of the animals were sacrificed at 1, 2, 3 weeks after surgery by using of perfusion technique. For obtaining histological section, tissues were fixed in 2.5% Glutaraldehyde (0.1M cacodylate buffer, pH 7.2) and Karnovsky's fixative solution, and decalcified with 0.1M disodium ethylene diaminetetraacetate for 3 weeks. Tissue embeding was performed in paraffin and cut parallel to the surface of calvaria. Section in 7${\mu}m$ thickness of tissue was done and stained with Hematoxylin-Eosin. All the specimens were observed under the light microscopy. The following results were obtained. 1 . During the whole period of experiment, fibrous connective tissue was revealed at 1week after surgery which meant rapid soft tissue recovery. The healing rate of defected area into new bone formation of the test group was observed more rapid tendency than other two groups. 2 . The sequence of healing rate of bone defected area was as follows ; test group, positive control, negative control group. 3 . During the experiment, an osteoclastic cell around preexisted bone was not found. New bone formation was originated from the periphery of the remaing bone wall, and gradually extended into central portion of the bone defect. 4 . The biodegradable barrier membrane was observed favorable biocompatibility during this experimental period without any other noticeable foreign body reaction. And mineralization in the newly formed osteoid tissue revealed relatively more rapid than other group since early stage of the healing process. Conclusively, the cultured bone cell inoculated onto the biodegradable barrier membrane may have an important role of regeneration of artificial bone defects of alveolar bone. This study thus demonstrates a tissue-engineering the approach to the repair of bone defects, which may have clinical applications in clinical fields of the dentistry including periodontics.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Effect of Attenuation Correction, Scatter Correction and Resolution Recovery on Diagnostic Performance of Quantitative Myocardial SPECT for Coronary Artery Disease (감쇠보정, 산란보정 및 해상도복원이 정량적 심근 SPECT의 관상동맥질환 진단성능에 미치는 효과)

  • Hwang, Kyung-Hoon;Lee, Dong-Soo;Paeng, Jin-Chul;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.5
    • /
    • pp.288-297
    • /
    • 2002
  • Purpose: Soft tissue attenuation and scattering are major methodological limitations of myocardial perfusion SPECT. To overcome these limitations, algorithms for attenuation, scatter correction and resolution recovery (ASCRR) is being developed, while quantitative myocardial SPECT has also become available. In this study, we investigated the efficacy of an ASCRR-corrected quantitative myocardial SPECT method for the diagnosis of coronary artery disease (CAD). Materials and Methods: Seventy-five patients (M:F=51:24, $61.0{\pm}8.9$ years old) suspected of CAD who underwent coronary angiography (CAG) within $7{\pm}12$ days of SPECT(Group-I) and 20 subjects (M:F=10:10, age $40.6{\pm}9.4$) with a low likelihood of coronary artery disease (Group-II) were enrolled. Tl-201 rest/ dipyridamole-stress Tc-99m-MIBI gated myocardial SPECT was performed. ASCRR correction was peformed using a Gd-153 line source and automatic software (Vantage-Pro; ADAC Labs, USA). Using a 20-segment model, segmental perfusion was automatically quantified on both the ASCRR-corrected and uncorrected images using an automatic quantifying software (AutoQUANT; ADAC Labs.). Using these quantified values, CAD was diagnosed in each of the 3 coronary arterial territories. The diagnostic performance of ASCRR-corrected SPECT was compared with that of non-corrected SPECT. Results: Among the 75 patients of Group-I, 9 patients had normal CAG while the remaining 66 patients had 155 arterial lesions; 61 left anterior descending (LAD), 48 left circumflex (LCX) and 46 right coronary (RCA) arterial lesions. For the LAD and LCX lesions, there was no significant difference in diagnostic performance. In Group-II patients, the overall normalcy rate improved but this improvement was not statistically significant (p=0.07). However, for RCA lesions, specificity improved significantly but sensitivity worsened significantly with ASCRR correction (both p<0.05). Overall accuracy was the same. Conclusion: The ASCRR correction did not improve diagnostic performance significantly although the diagnostic specificity for RCA lesions improved on quantitative myocardial SPECT. The clinical application of the ASC-RR correction requires more discretion regarding cost and efficacy.

Gender Difference of Accuracy in Detecting Coronary Artery Disease by Myocardial Perfusion SPECT (디피리다몰 심근관류 SPECT를 이용한 관동맥질환 진단에 있어 남녀간의 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.129-136
    • /
    • 1998
  • Purpose: Myocardial SPECT is an effective test for detecting coronary artery disease in the general population. But the diagnostic accuracy between sexes is not defined. The purpose of this study is to compare the diagnostic accuracy between males and females. Materials and Methods: One hundred and seventy seven male and 98 female patients who underwent myocardial SPECT within 1 month of coronary angiography were studied. Myocardial SPECTS were considered abnormal if fixed or reversible perfusion defects were detected. Stenosis severity of ${\geq}$ 50% luminal diameter reduction of any artery defined coronary artery disease (CAD). Results: Overall sensitivity for detection of CAD was 98% in men and 97% in women (p=not significant). However, specificities, accuracies, and positive predictive values (PPV) in men and women were 49% vs 31% (p<0.05), 81% vs 57% (p<0.01), 78% vs 48% (p<0.01), respectively. Diagnostic accuracies for detection of right coronary artery disease were not different in both sexes, however, accuracies for detection of left anterior descending artery disease and left circumflex artery disease were significantly lower in female (p<0.05). Conclusion: A significant difference of diagnostic accuracy between sexes, especially in LAD and LCx disease, was noted. Artifacts from breast attenuation might be a cause for the lower diagnostic accuracy in female.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Cytotoxicity and Apoptosis of Various Concentrations of Doxorubicin in Methylcholanthrene- induced Rat Fibrosarcoma(MCA) Cells (Methylcholanthrene 유도 섬유육종세포주에서 Doxorubicin 농도에 따른 세포독성과 자멸사의 변화)

  • 정진용;왕영필;나석주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.447-453
    • /
    • 2001
  • Background: Although pulmonary resection is the standard approach for the management of pulmonary metastases from soft tissue sarcoma, most of them are unresectable and chemotherapy remains the only option. The effectiveness of the cytotoxic drugs may be limited by the toxicities that occur before the therapeutic dose is reached. The regional administration of doxorubicin using pulmonary arterial perfusion in a rodent model can produce 10 to 25 times higher concentrations in the lung than systemic administration with minimal systemic toxicities. However, it is unclear whether a high concentration of doxorubicin has beneficial effects for killing cancer cells. Material and Method: We studied this to evaluate the dose-dependent cytotoxic and apoptotic effects of doxorubicin on methylcholanthrene-induced rat fibrosarcoma(MCA) cells. This study examined the cytotoxicity and apoptosis-related gene expressions(Fas, FasL, Bax, caspase 1, caspase 2, caspase 8, Bcl-2, Bcl-xL, Bcl-xS) in MCA cells after 24 hours exposure to various concentrations of doxorubicin such as 1, 5, 10, 50, and 100 $\mu$M. Result: Dose-dependent cytotoxicity was observed after 24 hours exposure to doxorubicin. However, peak apoptosis after 24 hours exposure was observed at 5 $\mu$M of doxorubicin. Above 5 $\mu$M, apoptotic activity was decreased with dose-increment. All mRNA levels of apoptosis-related genes after 24 hours exposure were up-regulated above the control level at 1 $\mu$M of doxorubicin and then decreased by doxorubicin dose-increment except caspase 8, which showed higher levels than the control level at 5 $\mu$M. Apoptosis-related protein levels were highest at 1 $\mu$M of doxorubicin and then decreased by doxorubicin dose-increment. However, Bax and Bcl-xL proteins steadily showed higher levels than the control throughout the different concentrations of doxorubicin. Conclusion: These results suggest that apoptosis is the main cytotoxic mechanism in low concentrations of doxorubicin in MCA cells and apoptosis-related genes, such as Bax, caspase 8, and Bcl-xL, are involved. At high concentrations, doxorubicin still can kill MCA cells, even when apoptosis is inhibited, and have its propriety for achieving much cytotoxicity against MCA cells.

  • PDF