• Title/Summary/Keyword: Soft tissue liner

Search Result 13, Processing Time 0.018 seconds

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

A ROENTGENOCEPHALOMETRIC STUDY OF SOFT TISSUE PROFILE FOR THE CHILDREN IN THE DECIDUOUS DENTITION (유치열기(乳齒列期) 아동(兒童)의 악안면연조직(顎顔面軟組織)의 두부방사선(頭部放射線) 계측학적(計測學的) 연구(硏究))

  • Kim, Dong-Phil;Kim, Nam-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.11 no.1
    • /
    • pp.191-213
    • /
    • 1984
  • This study was made on the facial profile of the normal Korean children using the roentgenographic cephalograms. The subjects consisted 51 males and 47 females children of primary dentition with the normal occlusion and acceptable profile. For this study 13 soft tissue profile landmarks were plotted and 14 liner length, 9 soft tissue thickness, 8 vertical height length, 12 angles of soft tissue profile, and 2 vertical proportion were measured. The mean and standard deviations in the subjects were calculated and compared between male and female. The following results were obtained : 1. By the significant test, total facial convexity angle and soft tissue thickness were no significant difference between both sexes. 2. Lower facial height was greater than upper facial height in both sexes. 3. The vertical length of the upper and lower lips were 21.95 mm, 40.74 mm in male and 21.62 mm, 39.63 mm in female. 4. In the relationship of the upper lip and lower lip to the Ricketts' esthetic line, the male was 1.3 mm, 1.18 mm and the female was 1.16 mm, 1.27 mm front of the esthetic line. 5. Compared with the angulation of flush terminal plane group and mesial step group, the mesial step group was greater than the flush terminal plane group except the chin angle.

  • PDF

A STUDY ON THE VISCO-ELASTIC PROPERTIES OF FOUR CURRENTLY USED TISSUE CONDITIONERS (수종의 조직 양화재에서 탄성 변형과 복원에 관한 연구)

  • Choi Sung-Ho;Shim June-Sung;Moon Hong-Seok;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.35-47
    • /
    • 2003
  • The dimensional stability of tissue conditioners characterizes the ability of the materials to yield accurate functional impressions of oral mucosa. This study evaluated the viscoelastic property and the linear dimensional changes with the factor of time and thickness of tissue conditioners ($COE-COMFORT^{TM}$, Visco-gel. $COE-SOFT^{TM}$, Soft-Liner). The thickness of these materials were changed (1.5mm, 3.0mm) and the percentage changes in dimension were measured at 1h, 12h, 24h, 36h, 3day, 7day after specimen preparation. From the results large differences appear between the various tissue conditioners. The results suggest that the period recommended for forming functional impression would be 2-3days after insertion in the mouth. in addition. it is important to select tissue conditioners suitable for functional impression because of the wide range of dimensional stability among the materials.

IN VITRO STUDY ON THE ADHERENCE AND PENETRATION OF CANDIDA ALBICANS INTO DENTURE SOFT LINING MATERIALS (의치 연성이장재에 대한 Candida albicans의 부착과 침투연구)

  • Kim Min-Ju;Shin Sang-Wan;Lee Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.466-476
    • /
    • 2006
  • Purpose : Colonization of denture soft lining materials by Candida albicans can result in clinical problem, and deterioration of the materials. This study aimed to compare the retention and penetration of C. albicans into four denture soft lining materials commonly used. Materials and methods : Four denture soft lining materials (Coe-comfort$^{(R)}$, Coe-soft$^{(R)}$, GC soft liner$^{(R)}$, and Tissue conditioner$^{(R)}$) discs were prepared to glass slide and dental stone. Adherence of yeast to surfaces was monitored after one hour incubation of standardized washed cell suspension with test disc surfaces. Adherent cells stained with acridine orange were counted fluorescence microscopy. Penetration of yeast into materials bonded with acrylic resin after 1, 2, 3,4, 5, 6 and 7 days incubation was observed through sections stained using acridine orange and estimated to quantitative analysis using radioisotope. Results : There was statistical significance in cell numbers between smooth and rough surfaces(p<0.05). Higher numbers of cells were observed on rough surfaces. There was statistical significance in adherent cell numbers into smooth and rough surfaces individually(p<0.05). According to the increase of incubation periods, the cells penetrated into denture soft lining materials were shown to increase. The differences among all kinds of soft liner were statistically significant(p<0.05),and the largest number of cells penetrated into soft liners was observed in the Coe-soft$^{(R)}$. Conclusion : Initial adherence and penetration of yeast into denture soft lining materials has been influenced by surface roughness and chemical composition of them. The selection of appropriate materials and their fabrication may promote clinical performance.

Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners (수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화)

  • Kim, Kyung-Soo;Moon, Hong-Suk;Shim, June-Sung;Jung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-118
    • /
    • 2009
  • Statement of problem: Volume stability, microstructure reproducibility and fluidity along with compatibility with dental stone must be in consideration in order to use tissue conditioner as a material for functional impression. There are few studies concerning the influence of time factor in oral condition on surface roughness of the stone and optimal retention period in the oral cavity considering such changes in surface roughness. Purpose: The purpose of this study was to find out the influence of various kinds of tissue conditioner, its powder/liquid ratio and immersion time on surface roughness of the stone. Material and methods: Materials used in this study were the three kinds of tissue conditioners(Coe-Comfort, Visco-Gel, Soft-Liner) and were grouped into three: group R-mixed with standard powder/liquid ratio that was recommended by the manufacturers, group M-mixed with 20% more powder, group L-mixed with 20% less powder. Specimens were made with the size of 20 mm diameter and 2 mm width. Each tissue conditioner specimens were subdivided into 5 groups according to the immersion time(0 hour, 1 day, 3 days, 5 days, 7 days), completely immersed into artificial saliva and were stored under $37^{\circ}C$. Specimens of which the given immersion time elapsed were taken out and were poured with improved stone, making the stone specimens. Surface roughness of the stone specimens was measured by a profilometer. Results: Within the limitation of this study, the following results were drawn. 1. Major influencing factor on surface roughness of the stone model made from tissue conditioner was the retention period(contribution ratio($\rho$)=62.86%, P<.05) of the tissue conditioner in oral cavity to make functional impression. 2. In case of Coe-Comfort, higher mean surface roughness value of the stone model with statistical significance was observed compared to that of Soft-Liner and Visco-Gel as immersion time changes(P<.05). 3. In case of group L(less), higher mean surface roughness value of the stone model with statistical significance was observed compared to that of R(recommended) and M(more) group as immersion time changes(P<.05). Conclusion: We may conclude that as the retention period of time in oral cavity influences surface roughness of the stone model the most and as the kind of tissue conditioner and its P/L ratio may influence also, clinician should well understand the optimal retention period in oral cavity and choose the right tissue conditioner for the functional impression, thus making the functional impression with tissue conditioner usefully.

THE EFFORT OF VARIOUS MIXING METHODS ON DYNAMIC VISCOELASTICITY OF A TEMPORARY SOFT LINING MATERIAL; COE-COMFORT

  • Ryu Hyun-Ju;Bae Hanna-Eun-Kyong;Shim June-Sung;Lee Seok-Hyung;Moon Hong-Suk;Chung Mun-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.641-646
    • /
    • 2004
  • Statement of Problem. Temporary soft relining materials are used in a diverse clinical situations such as tissue conditioner, relining material, functional impression by varying its viscoelasticity. However, reproduction of consistent viscoelasticity has been not possible. Materials and methods. Considering setting mechanism of this material, this study has measured the effect of varying amount of void in dynamic viscoelasticity of soft relining material, with three different mixing methods. In each methods 10 specimens were made and subjected to dynamic viscoelastic test which were measured at specific times over period of 72 hours. Results. The analysis of the result shown that there was no statistically significant differences between different mixing methods. Conclusion. Different mixing methods had no effect over control of viscoelasticity of soft lining material. Further research is recommended for under similar oral environmental condition.

A Study on the Improvement of Denture Base construction (의치상(義齒床) 개선(改選)에 관한 연구(硏究))

  • Shin, Moo-Hak
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.133-138
    • /
    • 1992
  • The base of a metal base denture that is made of acrylic resin base and metal in lined by soft liner named silicon rubber and its merits are as follows. 1. It has a good retention and fastness. 2. It has a good comfort and stability. 3. It is easy to mix various kinds of base materials. 4. It is easy to repair. 5. The pressure of bone and mucosal tissue is decreased and bite force is dispersed.

  • PDF

Tissue conditioner in edentulous patients, depending on the time and the thickness of the changes affect the dimensional stability (무치악 환자에서 조직양화제(tissue conditioner)가 시간과 두께에 따라 체적안정성의 변화에 미치는 영향)

  • Shim, Youn-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3794-3801
    • /
    • 2010
  • This study evaluated the linear dimensional changes with the factor of time and thickness using of three commercially available tissue conditioners (Coe-Comport, Visco-Gel, Soft-Liner). The thickness of materials were changed (1.5mm, 3.0mm) and the percentage changes in dimension were measured at 1h(baseline), 12h, 24h, 3 days and 7days after specimen preparation. The obtained data were analyzed by ANOVA with the SAS/PC statistical package. From the results, large differences appear between the various tissue conditioners. The results suggested that the period recommended for forming functional impression would be 36h to 3days after insertion in the mouth. Depending on the type of tissue conditioner over time, as there were significant differences in the elastic change(p<0.05). Tissue conditioner of the 1.5mm, 3.0mm thickness were significantly different by the dimensional stability(p<0.05). Elastic deformation of the ideal itself, and resilient when compared only the look, Visco-Gel 3.0mm group, stability was the most stable volume. In addition, it is important to select tissue conditioners suitable for functional impression because of the wide range of dimensional stability among the materials.

In vitro antimicrobial effect of the tissue conditioner containing silver nanoparticles

  • Nam, Ki-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.20-24
    • /
    • 2011
  • PURPOSE. The aim of this study was to identify in vitro antimicrobial activity of the tissue conditioner containing silver nanoparticles on microbial strains, Staphylococcus aureus, Streptococcus mutans and Candida albicans. MATERIALS AND METHODS. Experimental disc samples ($20.0{\times}3.0$ mm) of tissue conditioner (GC Soft-Liner, GC cooperation, Tokyo, Japan) containing 0.1 - 3.0% silver nanoparticles (0%: control) were fabricated. Samples were placed on separate culture plate dish and microbial suspensions (100 ${\mu}L$) of tested strains were inoculated then incubated at $37^{\circ}C$. Microbial growth was verified at 24 hrs and 72 hrs and the antimicrobial effects of samples were evaluated as a percentage of viable cells in withdrawn suspension (100 ${\mu}L$). Data were recorded as the mean of three colony forming unit (CFU) numerations and the borderline of the antimicrobial effect was determined at 0.1% viable cells. RESULTS. A 0.1% silver nanoparticles combined to tissue conditioner displayed minimal bactericidal effect against Staphylococcus aureus and Streptococcus mutans strains, a 0.5% for fungal strain. Control group did not show any microbial inhibitory effect and there were no statistical difference between 24 hrs and extended 72 hrs incubation time (P > .05). CONCLUSION. Within the limitation of this in vitro study, the results suggest that the tissue conditioner containing silver nanoparticles could be an antimicrobial dental material in denture plaque control. Further mechanical stability and toxicity studies are still required.

INHIBITORY EFFECT OF ANTIFUNGAL AGENTS INCORPORATED IN DENTURE LINING MATERIALS AGAINST CANDIDA ALBICANS (의치상 이장재 표면의 캔디다 균주에 대한 항균제의 억제 효과)

  • Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.293-300
    • /
    • 1999
  • The purpose of this study was to evaluate the in vitro antifungal effect of several kinds of denture lining materials containing nystatin and silver-zeolite on Candida albicans. Three commercially available tissue conditioners (Soft-Liner, Coe-Comfort, Coe-Soft) and two direct denture relining materials (Tokuso Rebase, Durabase) were selected. In terms of the zone of inhibition and some basic physical properties, I could find the following results ; 1. Nystatin or silver-zeolite included in those relining materials had definite antifungal activities against the Candida albicans. 2. As times went on, both of the antifungal agents's activities decreased gradually. 3. Antifungal agents did not affect the relining materials' basic physical properties. 4 Direct chairside relining materials showed unfavorable dark discoloration with response to silver-zeolite.

  • PDF