• Title/Summary/Keyword: Soft liner

Search Result 48, Processing Time 0.017 seconds

A ROENTGENOCEPHALOMETRIC STUDY OF SOFT TISSUE PROFILE FOR THE CHILDREN IN THE DECIDUOUS DENTITION (유치열기(乳齒列期) 아동(兒童)의 악안면연조직(顎顔面軟組織)의 두부방사선(頭部放射線) 계측학적(計測學的) 연구(硏究))

  • Kim, Dong-Phil;Kim, Nam-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.11 no.1
    • /
    • pp.191-213
    • /
    • 1984
  • This study was made on the facial profile of the normal Korean children using the roentgenographic cephalograms. The subjects consisted 51 males and 47 females children of primary dentition with the normal occlusion and acceptable profile. For this study 13 soft tissue profile landmarks were plotted and 14 liner length, 9 soft tissue thickness, 8 vertical height length, 12 angles of soft tissue profile, and 2 vertical proportion were measured. The mean and standard deviations in the subjects were calculated and compared between male and female. The following results were obtained : 1. By the significant test, total facial convexity angle and soft tissue thickness were no significant difference between both sexes. 2. Lower facial height was greater than upper facial height in both sexes. 3. The vertical length of the upper and lower lips were 21.95 mm, 40.74 mm in male and 21.62 mm, 39.63 mm in female. 4. In the relationship of the upper lip and lower lip to the Ricketts' esthetic line, the male was 1.3 mm, 1.18 mm and the female was 1.16 mm, 1.27 mm front of the esthetic line. 5. Compared with the angulation of flush terminal plane group and mesial step group, the mesial step group was greater than the flush terminal plane group except the chin angle.

  • PDF

THE EFFORT OF VARIOUS MIXING METHODS ON DYNAMIC VISCOELASTICITY OF A TEMPORARY SOFT LINING MATERIAL; COE-COMFORT

  • Ryu Hyun-Ju;Bae Hanna-Eun-Kyong;Shim June-Sung;Lee Seok-Hyung;Moon Hong-Suk;Chung Mun-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.641-646
    • /
    • 2004
  • Statement of Problem. Temporary soft relining materials are used in a diverse clinical situations such as tissue conditioner, relining material, functional impression by varying its viscoelasticity. However, reproduction of consistent viscoelasticity has been not possible. Materials and methods. Considering setting mechanism of this material, this study has measured the effect of varying amount of void in dynamic viscoelasticity of soft relining material, with three different mixing methods. In each methods 10 specimens were made and subjected to dynamic viscoelastic test which were measured at specific times over period of 72 hours. Results. The analysis of the result shown that there was no statistically significant differences between different mixing methods. Conclusion. Different mixing methods had no effect over control of viscoelasticity of soft lining material. Further research is recommended for under similar oral environmental condition.

A Study on the Improvement of Denture Base construction (의치상(義齒床) 개선(改選)에 관한 연구(硏究))

  • Shin, Moo-Hak
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.133-138
    • /
    • 1992
  • The base of a metal base denture that is made of acrylic resin base and metal in lined by soft liner named silicon rubber and its merits are as follows. 1. It has a good retention and fastness. 2. It has a good comfort and stability. 3. It is easy to mix various kinds of base materials. 4. It is easy to repair. 5. The pressure of bone and mucosal tissue is decreased and bite force is dispersed.

  • PDF

INHIBITORY EFFECT OF ANTIFUNGAL AGENTS INCORPORATED IN DENTURE LINING MATERIALS AGAINST CANDIDA ALBICANS (의치상 이장재 표면의 캔디다 균주에 대한 항균제의 억제 효과)

  • Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.293-300
    • /
    • 1999
  • The purpose of this study was to evaluate the in vitro antifungal effect of several kinds of denture lining materials containing nystatin and silver-zeolite on Candida albicans. Three commercially available tissue conditioners (Soft-Liner, Coe-Comfort, Coe-Soft) and two direct denture relining materials (Tokuso Rebase, Durabase) were selected. In terms of the zone of inhibition and some basic physical properties, I could find the following results ; 1. Nystatin or silver-zeolite included in those relining materials had definite antifungal activities against the Candida albicans. 2. As times went on, both of the antifungal agents's activities decreased gradually. 3. Antifungal agents did not affect the relining materials' basic physical properties. 4 Direct chairside relining materials showed unfavorable dark discoloration with response to silver-zeolite.

  • PDF

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.

Effect of aging on tear strength and cytotoxicity of soft denture lining materials; in vitro

  • Landayan, Jordi Izzard Andaya;Manaloto, Adrian Carlos Francisco;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of aging on the tear strength and cytotoxicity of four soft denture lining materials. MATERIALS AND METHODS. Four commonly used soft denture lining materials, (Coe-Comfort$^{TM}$ GC America Inc., Alsip, IL, USA; Coe-SOFT$^{TM}$ GC America Inc., Alsip, IL, USA; Visco-gel Dentsply Caulk Milford, DE, USA; and Sofreliner Tough M Tokuyama Dental Corporation Tokyo, Japan) were selected. Sixty trouser-leg designed specimens per lining material were fabricated using a stainless steel mold for tear strength testing. The specimens were divided into non-thermocycling and 1000-, and 3000-thermocycling groups. For the cytotoxicity test, twenty-four disk shaped specimens per material were fabricated using a stainless steel mold. The specimens were soaked in normal saline solution for 24 h, 48 h and 72 h. Cytotoxicity was measured by XTT assay in L929 mouse fibroblasts. Data were analyzed by two way analysis of variance and Dunnett's test (P<.05). RESULTS. Before thermocycling, Sofreliner Tough M ($10.36{\pm}1.00N$) had the highest tear strength value while Coe-Comfort$^{TM}$ ($0.46{\pm}0.10N$) had the lowest. After 3000 cycles, Sofreliner Tough M ($9.65{\pm}1.66N$) presented the highest value and Coe-Comfort$^{TM}$ ($0.42{\pm}0.08N$) the lowest. Sofreliner Tough M, in all incubation periods was the least toxic with significant differences compared to all other materials (P<.05). Coe-Comfort$^{TM}$, Coe-$SOFT^{TM}$, and Sofreliner Tough M did not show any significant differences within their material group for all incubation periods. CONCLUSION. This in vitro study revealed that aging can affect both the tear strength and cytotoxicity of soft denture materials depending on the composition.

Functional impression technique using temporary denture for rehabilitation of severely atrophic maxillary and mandibular ridges (심한 치조제 흡수를 보이는 무치악 환자에서 임시 의치를 사용한 기능 인상에 의한 총의치 수복 증례)

  • Suh, Young-Kyo;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.238-244
    • /
    • 2019
  • Soft liner is used to functional impression technique when dental stone is immediately poured after taking impression because of viscoelasticity. In this case, a 78-year-old male visited for new dentures. Due to severe resorption of mandibular edentulous ridge, functional impression taking by closed mouth technique was planned. First of all, making maxillary and mandibular provisional dentures was done, and lined by soft liner to rehabilitate pressured maxillary and mandibular edentulous ridge. After this, Functional impression was taken by closed mouth technique using provisional dentures which are transformed to healed maxillary and mandibular edentulous ridge, and final denture were fabricated using maxillary provisional denture as a reference of artificial teeth arrangement. Consequently, restoring a complete edentulous patient with taking functional impression using provisional dentures resulted in recovering satisfying retention and function.

A STUDY ON THE VISCO-ELASTIC PROPERTIES OF FOUR CURRENTLY USED TISSUE CONDITIONERS (수종의 조직 양화재에서 탄성 변형과 복원에 관한 연구)

  • Choi Sung-Ho;Shim June-Sung;Moon Hong-Seok;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.35-47
    • /
    • 2003
  • The dimensional stability of tissue conditioners characterizes the ability of the materials to yield accurate functional impressions of oral mucosa. This study evaluated the viscoelastic property and the linear dimensional changes with the factor of time and thickness of tissue conditioners ($COE-COMFORT^{TM}$, Visco-gel. $COE-SOFT^{TM}$, Soft-Liner). The thickness of these materials were changed (1.5mm, 3.0mm) and the percentage changes in dimension were measured at 1h, 12h, 24h, 36h, 3day, 7day after specimen preparation. From the results large differences appear between the various tissue conditioners. The results suggest that the period recommended for forming functional impression would be 2-3days after insertion in the mouth. in addition. it is important to select tissue conditioners suitable for functional impression because of the wide range of dimensional stability among the materials.

Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners (수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화)

  • Kim, Kyung-Soo;Moon, Hong-Suk;Shim, June-Sung;Jung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-118
    • /
    • 2009
  • Statement of problem: Volume stability, microstructure reproducibility and fluidity along with compatibility with dental stone must be in consideration in order to use tissue conditioner as a material for functional impression. There are few studies concerning the influence of time factor in oral condition on surface roughness of the stone and optimal retention period in the oral cavity considering such changes in surface roughness. Purpose: The purpose of this study was to find out the influence of various kinds of tissue conditioner, its powder/liquid ratio and immersion time on surface roughness of the stone. Material and methods: Materials used in this study were the three kinds of tissue conditioners(Coe-Comfort, Visco-Gel, Soft-Liner) and were grouped into three: group R-mixed with standard powder/liquid ratio that was recommended by the manufacturers, group M-mixed with 20% more powder, group L-mixed with 20% less powder. Specimens were made with the size of 20 mm diameter and 2 mm width. Each tissue conditioner specimens were subdivided into 5 groups according to the immersion time(0 hour, 1 day, 3 days, 5 days, 7 days), completely immersed into artificial saliva and were stored under $37^{\circ}C$. Specimens of which the given immersion time elapsed were taken out and were poured with improved stone, making the stone specimens. Surface roughness of the stone specimens was measured by a profilometer. Results: Within the limitation of this study, the following results were drawn. 1. Major influencing factor on surface roughness of the stone model made from tissue conditioner was the retention period(contribution ratio($\rho$)=62.86%, P<.05) of the tissue conditioner in oral cavity to make functional impression. 2. In case of Coe-Comfort, higher mean surface roughness value of the stone model with statistical significance was observed compared to that of Soft-Liner and Visco-Gel as immersion time changes(P<.05). 3. In case of group L(less), higher mean surface roughness value of the stone model with statistical significance was observed compared to that of R(recommended) and M(more) group as immersion time changes(P<.05). Conclusion: We may conclude that as the retention period of time in oral cavity influences surface roughness of the stone model the most and as the kind of tissue conditioner and its P/L ratio may influence also, clinician should well understand the optimal retention period in oral cavity and choose the right tissue conditioner for the functional impression, thus making the functional impression with tissue conditioner usefully.

THE STUDY ON THE PHYSICAL PROPERTY OF THE PERMANENT SOFT DENTURE LINERS (영구 연성 의치상 이장재의 물리적 성질에 관한 연구)

  • Kim, Yeon-Mi;Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.809-818
    • /
    • 1999
  • This study was performed to evaluate the tensile bond strength and modulus of elasticity of three permanent soft denture liners (Molloplast $B^{(R)}$, Ufi Gel $C^{(R)},\;Tokuyama^{(R)}$) before and after thermocycling. And their water sorption were also evaluated. Each soft denture liner was bonded to PMMA denture base resin blocks and the tensile bond strength and modulus of elasticity were measured by using universal testing machine. For the water sorption, weight measured after immersion of sea denture liners in $37{\pm}1^{\circ}C$ water bath for 4 weeks. The results were as follows : 1. Molloplast $B^{(R)}$ had the highest tensile bond strength, while Tokuyama had the lowest tensile bond strength. There was no significant difference between $Tokuyama^{(R)}$ and Molloplast $B^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in tensile strength of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 2. For the modulus of elasticity, there was no significant difference between Ufi Gel $C^{(R)}\;and\;Tokuyama^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in modulus of elasticity of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 3 The failure modes of Molloplast $B^{(R)}$ and Ufi Gel $C^{(R)}$ were mainley adhesive type and that of $Tokuyama^{(R)}$ was mainly mixed type in case of nonthermocycling and cohesive type after thermocycling. 4. The water sorption of each soft liners was within ${\pm}2%$ in times (p<0.05) but. there was no significant difference among the soft liners in times.

  • PDF