• Title/Summary/Keyword: Soft lenses fitting

Search Result 15, Processing Time 0.019 seconds

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

A Comparison of the Movements of Circle Contact Lens and Soft Contact Lens with Identical Material on Cornea (써클 콘택트렌즈와 동일 재질 소프트 콘택트렌즈의 각막에서의 움직임 비교)

  • Kim, So Ra;Park, Sang Hee;Joo, Seon-Ok;Lee, Hye Rim;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: The present study was conducted to compare any difference caused by pigmentation in the centrations and movement patterns on the cornea between circle and soft contact lens with identical material and parameters during lens wearing. Methods: Soft and circle contact lenses with identical material and parameters were applied to twenty eyes with normal tear volume for 3 hrs a day during a total of 5 days and then their lens centrations, the moving distances and rotations by repeat blinking were compared. Results: The lens centration beyond the fitting criteria was shown in initial wears of both soft contact lens and circle contact lens. However, the centration of soft contact lens was changed to the pupil center for being suitable to the fitting criteria with longer wearing time. On the other hand, the decentration of circle contact lens in the horizontal direction was still presented even with longer wearing time. The moving distances of soft contact lens and circle contact lens decreased with the expand of lens wearing but were not significantly different between total wearing period and daily wearing time. The rotation of circle contact lens by repeat blinking was significantly different from that of soft contact lens even when the wearing period was extended. Conclusions: We revealed that the lens centration and movement of circle contact lens on cornea were different from those of regular soft contact lens resulting in bigger difference with the expand of wearing period in the study.

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF