• Title/Summary/Keyword: Soft Value

Search Result 794, Processing Time 0.025 seconds

Fabrication and Structural Observation of a Soft Magnetic Composite Powders by Mechanical Alloying (기계적합금화법에 의한 연자성 복합분말의 제조 및 구조관찰)

  • Lee, Chung-Hyo
    • Korean Journal of Materials Research
    • /
    • v.29 no.4
    • /
    • pp.252-257
    • /
    • 2019
  • Fabrication of soft magnetic composite powders for the $Fe_2O_3-Ca$ system by mechanical alloying(MA) has been investigated at room temperature. It is found that soft magnetic composite powders in which CaO is dispersed in ${\alpha}-Fe$ matrix are obtained by MA of $Fe_2O_3$ with Ca for 5 hours. Changes in magnetization and coercivity also reflect the details of the solidstate reduction process of hematite by pure metal of Ca during MA. The saturation magnetization of MA powders increases with increasing MA time and reaches a maximum value of 65 emu/g after 7 hours of MA. The average grain size of ${\alpha}-Fe$ in MA powders, estimated by diffraction line-width, gradually decreases with increasing MA time and reaches 52 nm after 5 hours of MA. It can also be seen that the coercivity of the 5-hour MA sample is fairly high at 190 Oe, suggesting that the grain refinement of already-produced ${\alpha}-Fe$ tends to clearly occur during MA.

A Monochromatic Soft X-ray Generation from Femtosecond Laser-produced Plasma with Aluminum

  • Son, Joon-Gon;Hwang, Byung-Jun;Seo, Okkyun;Kim, Jae Myung;Noh, Do Young;Ko, Do-Kyeong
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1834-1839
    • /
    • 2018
  • A tabletop ultrafast soft x-ray has been generated from the laser-produce plasma with a femtosecond pulsed Ti:Sapphire laser. The estimated total flux of Al $K{\alpha}$ is of $2.2{\times}10^9photons/sec$ in $4{\pi}$ radian and the parameters related to the optical performance were obtained. The tungsten/silicon multilayer, flat quartz and bent thallium acid phthalate (TLAP) crystal were used for monochromatization of soft x-ray to refine the aluminum $K{\alpha}$ radiation and compared the respective value of $E/{\Delta}E$. To estimate the size of the x-ray source beam generated by a fs laser, the approximation using the FWHM obtained from the x-ray beam scan near the focal point was discussed, and the size of the diameter was about $9.76{\mu}m$.

Heritage Soft Power in East Asia's Memory Contests: Promoting and Objecting to Dissonant Heritage in UNESCO

  • Nakano, Ryoko
    • Journal of Contemporary Eastern Asia
    • /
    • v.17 no.1
    • /
    • pp.50-67
    • /
    • 2018
  • Heritage has entered the center stage of public diplomacy in East Asia. Competition to claim and interpret memories of World War II in East Asia has driven campaigns to list heritage items with UNESCO. State and non-state actors aim to use heritage listings to present a particular view of the war and related history to domestic and international audiences. This paper highlights the role of heritage soft power in East Asia's "memory contests" by examining the promotion of dissonant modern heritage in UNESCO's heritage programs. It conceptualizes heritage designation as a soft power resource in East Asia and presents a conceptual framework for understanding the hegemonic competition over the "memory regime" that emerged from the structural change in East Asia's regional order. It then uses this framework to analyze the processes by which state and non-state actors promote and/or object to UNESCO recognition of their sites and documents as heritage of outstanding universal value or world significance. The elements of this process are illustrated with case studies of two very different pieces of heritage, Japan's "Sites of the Meiji Industrial Revolution" and China's "Documents of Nanjing Massacre," which were enshrined as significant world heritage in 2015. While state and non-state actors in East Asia are increasingly recognizing the utility of heritage as a soft power resource for advancing specific historical narratives to an international audience, a backlash movement from civil society groups and governments in other countries prevents a purely unilateral interpretation. As a result, the utility of heritage soft power in this context must be significantly qualified.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

Soft Tissue Change After Single Jaw(mandible) Surgery in Skeletal Class III Malocclusion (골격성 III급 부정교합자의 편악(하악)수술후 연조직 변화의 평가)

  • Park, Kwang-Soo;Lee, Hee-Kyung;Chin, Byung-Rho
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.197-208
    • /
    • 1997
  • The purpose of this study was to evaluate the amount and interrelationship of the soft and hard tissue change after mandibular setback surgery in skeletal Class III malocclusion. The sample consisted of 25 adult patient (12 male and 13 female) who had severe anteropostrior skeletal discepancy. These patient had received presurgical orthodontic treatment and surgical treatment which is bilateral sagittal split ramus osteotomy. The presurgical and postsurgical lateral cephalograms were evaluated. The computerized statistical analysis was carried out with SPSS/PC program. The result were as follows: 1. After mandibular bilateral sagittal split ramus osteotomy, lower facial soft. tissue horizontal posterior changes were high significance value. but vertical soft tissue changes were low significance value. 2. After mandibular bilateral sagittal split ramus osteotomy, relative upper lip protrusion increased(p<0.01) and relative lower lip protrusion decreased(p<0.01) and lower facial soft tissue thickness increased(p<0.01).

  • PDF

S-100B in Extracranial Fracture Patients Without Head Trauma (두부 손상이 없는 골절 환자에서 혈중 S100B 단백질의 분석)

  • Park, Tae-Woong;Lee, Dong-Hoon;Lee, Sang-Jin;Kim, Sung-Eun;Kim, Chang-Woong
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.123-127
    • /
    • 2009
  • Purpose: There is an increasing amount of evidence that S100B could function as a marker of brain damage. However, the cerebral specificity of S100B has been questioned, so the extracerebral sources of S100B have been paid attention. We performed this investigation to show serum S100B levels after extracranial fracture in patients without current head injury and without prior neurological disease. Methods: At the emergency department, we obtained the blood samples within 6 hours from trauma patients hospitalized with extracranial fractures. S100B levels were compared between one fracture and more than two fractures, and analyzed according to the presence of soft tissue damage. Results: Patients with one fracture and those with more than two fractures did not differ by age (mean, 54.70 vs. 47.03, p=0.130), and there was no significant difference in the male-to-female ratio(33:32 vs. 21:12, p=0.226). In patients with one fracture, the mean value of S-100B was $0.56{\mu}g/L$ (95% CI: 0.35-0.77) whereas in those with more than two fractures, the corresponding value was $1.09{\mu}g/L$ (95% CI: 0.46-1.7, p=0.048). The S100B level of patients with soft tissue damage($1.32{\pm}0.38$) was higher than that of patients without soft tissue damage($0.81{\pm}0.21$), whether one fracture or more than two fractures(p=0.049). Conclusion: We present here that S100B levels were raised in 77% of patients with extracranial fractures without cerebral injury who were hospitalized from the emergency room and that the presence of soft tissue damage contributed to the increased S100B rather than the size of the fractured bone size or the number of fracturest. Thus, this study suggests that soft tissue injury may be considered as an important extracerebral source of S100B.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

A Case Study on the VE/LCC for selection on Improvement of Soft Soil Ground (연약지반처리공법 선정을 위한 VE/LCC 사례 분석)

  • Kim, Yong-Deuk;Lee, Young-Dae;Acharya, Nirmal Kumar
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.271-273
    • /
    • 2006
  • Because effect of value elevation is great as it is fast that construction VE is enforcement, VE at the design phase is more and more important more than construction process phase. But, is exerting negative impact for construction process phase by various problem that happen at design phase, and is causing discord to between project partners. Therefore, quality security in design phase is important first of all. Hereupon, this study emphasized that need VE at the design phase of extension plan forward more and more because achieved process that derive conceptional estimation by quantitative value calculating value index (V) through provision of design function point (F) and LCC expense (C) by comparison method of construction and chooses optimum method of construction through VE/LCC analysis example in improvement of soft soil ground method choice process of design phase.

  • PDF

Effect of Ultra-Soft and Soft Toothbrushes on the Removal of Plaque and Tooth Abrasion

  • Jeong, Moon-Jin;Cho, Han-A;Kim, Su-Yeon;Kang, Ka-Rim;Lee, Eun-Bin;Lee, Ye-Ji;Choi, Jung-Hyeon;Kil, Ki-Sung;Lee, Myoung-Hwa;Jeong, Soon-Jeong;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.18 no.3
    • /
    • pp.164-171
    • /
    • 2018
  • To improve the oral health status of Korean people, it is necessary to encourage proper oral hygiene management habits, such as toothbrushing, through appropriate health promotion techniques. Therefore, the purpose of this study was to evaluate the removal of plaque and tooth abrasion using ultra-soft (filament 0.11~0.12 mm) and soft toothbrushes for toothbrushing. The plaque removal was performed using a dentiform and Arti-spray, and the Patient Hygiene Performance (PHP) index was calculated as the sum total score divided by the total number of surfaces. In the abrasivity experiment, according to the number of brushings, a micro Vickers hardness tester was used, and a sample in the range of 280~380 Vickers hardness number was selected. The number of toothbrushing stroke were 1,800 (2 months), 5,400 (6 months), 10,800 (12 months), and 21,600 (24 months). The tooth abrasion was measured using a scanning electron microscope. Statistical analysis was performed using IBM SPSS Statistics 22.0 and a p-value <0.05 was considered significant. According to the results, there was no statistically significant difference in the degree of plaque removal between ultra-soft and soft toothbrushes. The difference in tooth abrasion between before and after toothbrushing was found to be greater with the soft toothbrushes than with the ultra-soft toothbrushes. Therefore, the ultra-soft toothbrush not only lowers tooth damage by reducing tooth abrasion, but also shows a similar ability to remove plaque as soft toothbrushes.

Three-Port Laparoscopic Exploration is not Sufficient for Patients with T4 Gastric Cancer

  • Huang, Hua;Jin, Jie-Jie;Long, Zi-Wen;Wang, Wei;Cai, Hong;Liu, Xiao-Wen;Yu, Hong-Mei;Zhang, Li-Wen;Wang, Ya-Nong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8221-8224
    • /
    • 2014
  • Gastric cancer continues to be a leading cause of cancer death. The majority of patients with gastric adenocarcinoma in China present with advanced disease. Ruling out unresectable cancers from an unnecessary "open" exploration is very important. The aim of this study was to assess the value of five-port anatomical laparoscopic exploration in T4 gastric cancer in comparison with three-port laparoscopic exploration and laparotomy exploration. We conducted a retrospective study on 126 patients with T4 stage scheduled for D2 curative gastrectomy based on computed tomography (CT) staging at Department of Gastric Cancer and Soft Tissue Sarcoma, Fudan University Shanghai Cancer Center, from Apr. 2011 to Apr. 2013. Laparotomy exploration (Group I), three-port laparoscopic exploration (Group II) or five-port anatomical laparoscopic exploration (Group III) were performed prior to radical gastrectomy. Accuracy rate for feasibility of D2 curative gastrectomy in laparotomy exploration and five-port anatomical laparoscopic exploration groups was higher than that in the three-port laparoscopic exploration group. Five-port anatomical laparoscopic exploration group had the highest accuracy resection rate (Group I vs Group II vs Group III,92.6% vs78.6% vs 97.7%; p<0.05) and shorter length of hospitalization (Group I vs Group II vs Group III, $9.58{\pm}4.17$ vs $6.13{\pm}2.85$ vs $5.00{\pm}1.81$; p<0.001). Three-port laparoscopic exploration has low accuracy rate for assessing feasibility of D2 curative gastrectomy and five-port anatomical laparoscopic exploration should be performed on patients with T4 gastric cancer.