• Title/Summary/Keyword: Soft Finger

Search Result 99, Processing Time 0.024 seconds

Soft Tissue Reconstruction of Finger and Hand Using Arterialized Venous Free Flap (동맥화 정맥 유리 피판술을 이용한 수부와 수지 연부조직 결손의 재건)

  • Kong, Byeong-Seon;Kim, Yong-Jin;Cho, Kwang-Woo
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2004
  • Flaps are necessary, when important structures such as bone, tendon, nerve and vessel are exposed. Arterialized venous free flap is suited to the coverage of finger and hand because the thickness of venous flap is thin. Authors performed 65 cases arterialized venous free flap for the soft tissue reconstruction of the hand and finger. The size of donor defect were from $1{\times}1cm\;to\;7{\times}12cm$. The mean flap area was $9.1cm^2$. The recipient sites were finger tip in 34 cases, finger shaft in 29 cases and hand in 2 cases. The donor sites were volar aspect of distal forearm in 40 cases, thenar area in 17 cases and foot dorsum in 6 cases. The types of arterialized venous free flap were A-A type in 4 cases and A-V type in 61 cases. The length of afferent vein was from 0.5 cm to 3 cm (mean 1.7 cm) and efferent vein was from 1 cm to 10 cm (mean 2.2 cm). 58 flaps(89.2%) survived eventually. 42 flaps(64.6%) survived totally without any complication. 8 flaps(12.3%) showed the partial necrosis but they were healed without any additional operations. 8 flaps (12.3%) showed the partial necrosis requiring the additional skin graft. We had a satisfactory result by using arterialized venous free flap for the soft tissue reconstruction of finger and hand. We believe that volar aspect of distal forearm, thenar area, foot dorsum are suited as a donor site and the short length of the flap pedicle, the strong arterail inflow affect the survival rate of arterialized venous free flaps.

  • PDF

Research of Stable Grapsing in Field Robot (Field-Robot의 안정적 파지운동 제어에 관한 연구)

  • 박경택;심재군;한현용;양순용;이병룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.492-495
    • /
    • 1997
  • This paper aims to derive a mathematical model of the dynamics of handling task in field robot which stable grasping and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraints of tight area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Thirdly, simulation results are shown and the effects of geometric constraints of contact-area are discussed. Finally, it is shown that even in the simplest case of dual single D.O.F. manipulators there exists a sensory feedback from sensing data of he rotational angle of the object to command inputs to joint actuators and this feedback connection from sensing to action eventually realizes secure grasping of the object, provided that he object is of rectangular shape and motion is confined to a horizontal

  • PDF

Reconstruction of Soft Tissue Defects in the Finger using Arterialized Venous Free Flaps (유리 동맥화 정맥 피판을 이용한 수지 연부조직 결손의 재건)

  • Lee, Young-Keun;Woo, Sang-Hyun;Lee, Jun-Mo;Ahn, Hee-Chan;Cheon, Ho-Jun
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • Purpose: To report the clinical results of the use of arterialized venous free flaps in reconstruction in soft tissue defects of the finger and to extend indications for the use of such flaps based on the clinical experiences of the authors. Materials and Methods: Eighteen patients who underwent arterialized venous free flaps for finger reconstruction, between May 2007 and July 2009 were reviewed retrospectively. The mean flap size was 4.7${\times}3.2$ cm. The donor site was the ipsilateral volar aspect of the distal forearm in all cases. There were 8 cases of venous skin flaps, 5 cases of neurocutaneous flaps, 4 cases of tendocutaneous flaps, 1 case of innervated tendocutaneous flap. The vascuality of recipient beds was good except in 4 cases (partial devascuality in 2, more than 50% avascuality (bone cement) in 2). Results: All flaps were survived. The mean number of included veins was 2.27 per flap. Mean static two-point discrimination was 10.5 mm in neurocutaneous flaps. In 3 of 5 cases where tendocutaneous flaps were used, active ROM at the PIP joint was 60 degrees, 30 degrees at the DIP joint and 40 degrees at the IP joint of thumb. There were no specific complications except partial necrosis in 3 cases. Conclusions: An arterialized venous free flap is a useful procedure for single-stage reconstruction in soft tissue or combined defect of the finger; we consider that this technique could be applied to fingers despite avascular recipient beds if the periphery of recipient bed vascularity is good.

  • PDF

Reconstruction of Multiple Digital Defects by Temporary Syndactylization Using a Lateral Arm Free Flap

  • Sae Hwi Ki;Jin Myung Yoon;Tae Jun Park;M. Seung Suk Choi;Min Ki Hong
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.745-749
    • /
    • 2022
  • Background Soft tissue defects of the multiple finger present challenges to reconstruction surgeons. Here, we introduce the use of a lateral arm free flap and syndactylization for the coverage of multiple finger soft tissue defects. Methods This retrospective study was conducted based on reviews of the medical records of 13 patients with multiple soft tissue defects of fingers (n = 33) that underwent temporary syndactylization with a microvascular lateral arm flap for temporary syndactylization from January 2010 to December 2020. Surgical and functional outcomes, times of flap division, complications, and demographic data were analyzed. Results Middle fingers were most frequently affected, followed by ring and index fingers. Mean patient age was 43.58 years. The 13 patients had suffered 10 traumas, 2 thermal burns, and 1 scar contracture. Release of temporary syndactyly was performed 3 to 9 weeks after syndactylization. All flaps survived, but partial necrosis occurred in one patient, who required a local transposition flap after syndactylization release. The mean follow-up was 15.8 months. Conclusion Coverage of multiple finger defects by temporary syndactylization using a free lateral arm flap with subsequent division offers an alternative treatment option.

Finger Tip Replantation (수지 첨부 절단의 재접합술)

  • Kong, Byeong-Seon;Kim, Yong-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.12 no.2
    • /
    • pp.105-111
    • /
    • 2003
  • It has been known that the vessels of the finger tip are very small and have many branches, so the anastomosis of this vessel is very difficult. But when this operation achieves success, the replanted finger tip provides adequate soft tissue, restoration of the length, sensory and nail. The authors describe the result of finger tip replantation in 94 patients, 103 finger tips, from October 1999 to June 2002. We performed the salvage procedure in all cases. The success rate of finger tip replantation was 74.8%. We achieved higher success rate, when we succeeded anastomosis of the central artery. The function of the replanted fingers was good. The average TAM was 80% and patient satisfaction was high. We be live that we can achieve higher success rate by anastomosing central artery and performing delicate salvage procedure.

  • PDF

Reconstruction of Soft Tissue Defect of the Finger with Thenar Free Flap (유리 무지구 피판술을 이용한 수지 연부조직 결손의 재건)

  • Noh, Seung Man;Kim, Jin Soo;Lee, Dong Chul;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.450-454
    • /
    • 2008
  • Purpose: From May 2000 to January 2008, We experienced the 10 cases of the thenar free flap for the coverage of the large volar soft tissue defect in the finger. Methods: The pedicles of the flap were the superficial palmar artery of radial artery and subcutaneous vein, and we anastomosed them to the digital artery and subcutaneous vein of the finger. Results: The average size of the flaps was $12cm^2$ and it was large enough to cover the entire color soft tissue defect of a phalanx or the defect of the neighbored phalanges. All of donor wounds were closed primarily. Conclusion: The color and skin texture of the flap was matched with the volar skin of the finger functionally and cosmetically and the debulking of the flap was not necessary. Other advantages were constant anatomic pedicle of the flap, minimal donor site morbidity, one operation field. We consider that the thenar free flap is another reliable and useful method for the reconstructing of the large volar defect of the finger especially at the situation of emergency.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Extraskeletal Chondroma of Finger in a Young Woman: A Case Report (젊은 여성의 수지에 발생한 골격외 연골종(Extraskeletal Chondroma): 증례 보고)

  • Kim, Jin Young;Kim, Min Kyu;Choi, Jong-Sun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.2
    • /
    • pp.64-68
    • /
    • 2013
  • Extraskeletal chondroma is a benign soft tissue tumor which is composed of hyaline cartilage but arises from the fibrous stroma rather than from mature cartilaginous or osseous tissue. Extraskeletal chondroma is relatively rare and occurs most frequently in the soft tissue around the joints of hands and feet. We present one case of extraskeletal chondroma in a finger of a young woman.

The Radial Artery Superficial Palmar (RASP) Branch Free Flap for Finger Soft Tissue Reconstruction (요골 동맥 표재 수장 분지 유리 피판술을 이용한 수지 연부 조직의 재건)

  • Kim, Yong-Jin;Suh, Young-Suk;Lee, Sang-Hyun;Hahm, Dong-Gil
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • The radial artery superficial palmar branch free flap is based on the perforators of the superficial palmar branch of the radial artery and its venae comitantes. This flap can be used as a sensible flap including palmar cutaneous branch of the median nerve. Forty radial artery superficial palmar branch free flaps were performed at Centum Institute during October 2010 to December 2011. There were 32 males and 8 females and their mean age were 48 years (range 30 to 66 years). The thumb injured in 13 patients, the index finger in 16 patients, the middle finger in 4 patients, the ring finger in 2 patients, and the little finger in 5 patients. The mean size of the flap was $2.5{\times}3.5$ cm(range $2{\times}2.5$ to $3{\times}7$ cm). The donor site was always closed primarily. The overall survival rate was 90.2 percent. The flaps showed well-padded tissue with glabrous skin. All patients have touch sensation and showed 12 mm two point discrimination in an average(range 8 to 15 mm). Donor site morbidity was conspicuous. One patient showed unsightly scar. Early postoperative range of motion of the affected thumb showed slightly limited radial and palmar abduction. But it improved after postoperative 2 months, and patients did not complaint limitation of motion. In conclusion, the radial artery superficial palmar branch free flap can be used as an option for soft tissue reconstruction of finger defects where local or island flaps are unsuitable.

  • PDF

Review Article Fingertip Replantation (수지첨부 접합수술)

  • Hahn, Hyun Oun
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.2
    • /
    • pp.132-138
    • /
    • 2011
  • Although finger tip replantation is popularized nowadays, it is not easy operations even for experienced surgeons. The indication for replantation to treat fingetip amputation is still controversial, but I think replantation for function and cosmetic absolute indication. This paper will discuss about methods of fingertip replantation and unexpected complications on soft tissue after operation.

  • PDF