Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

A New Snubber Circuit Combined Undelannd and McMurray Snubber for Diode-Clamped Four-level Inverter and Converter (Diode-Clamped 4-레벨 인버터 및 컨버터를 위한 Undeland 및 McMurray 스너버를 결합한 새로운 스너버 회로)

  • 성현제
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.224-227
    • /
    • 2000
  • 지금까지 멀티레벨 컨버터 및 인버터에 적용되어온 기존의 스너버는 턴온 스너버로 RLD 스너버 턴오프 스너버로 RCD 스너버를 사용하였으나 이들 RCD/RLD는 많은 소자를 필요로하며 스위칭시의 overvoltage와 스너버 손실이 큰 단점을 지니고 있다. 이와같은 문제점을 해결하기 위해 본 논문에서는 Diode-clamped 4-레벨 컨버터 및 인버터를 위한 새로운 스너버를 제안한다. 새로 제안하는 스너버는 Basic snubber unit로 특성이 좋은 Undeland 스너버와 수정된 RCD/RLD 스너버를 사용한다. 따라서 제안하는 스너버는 Undeland 스너버와 McMuray 스너버가 갖고 있는 특성 즉 사용소자의 수의 감소 과전압의 감소 스너버 손실의 감소 등과 좋은 특성을 지니고 있다 또한 본 논문에서 제안하는 4-레벨 컨버터 및 인버터를 위한 스너버 회로를 구성하는 방법은 다른 레벨의 멀티레벨 컨버터 및 인버터에도 적용가능하다,

  • PDF

ZVT PWM AC-DC Boost Converter with Active Snubber (능동 스너버를 갖는 ZVT PWM AC-DC 승압 컨버터)

  • Kim, Choon-Sam;Sung, Won-Ki;Lee, Jung-Moon;Choi, Chan-Sok;Kim, Soo-Hong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.214-220
    • /
    • 2008
  • Most of converter system could obtain almost unity power factor and make input current sinusoidal waveform, but they have many problems, such as electromagnetic interference and switching losses caused by switching noise in main switch. To solve these problems in hard switching PFC converter, soft switching converter using a resonant between capacitor and inductor is invented In this paper, advantages and disadvantages of conventional ZVT(Zero-Voltage-Transition) soft switching converter using a auxiliary resonant circuit is discussed. Then Improved ZVT soft switching converter proposed. This improved ZVT converter's operation principal, specific property, design scheme of main are described. From Simulation and experiment results of conventional ZVT soft switching and improved ZVT soft switching converter with active snubber, characteristics of the converter are confirmed.

A Study on the High-Power-Factor, High-Efficiency AC/DC Boost Converter with Non-Dissipative Snubber (무손실 스너버를 적용한 고역률, 고효률 AC/DC Boost 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.112-115
    • /
    • 2002
  • Previous AC/DC PFC Boost Converter perceives feed forward signal of input and feedback signal of output for average current-mode control. Previous Boost Converter, the quantity of input current will be decreased by the decrease of output current in light load, and also power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations using non-dissipative snubber. The proposed converter also has a high efficiency by non-dissipative snubber circuit. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

A Study on the ZVT DC/DC Boost Converter using Active Snubber (능동스너버를 이용한 ZVT DC/DC Boost 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Kim, Pill-Soo;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.186-189
    • /
    • 2002
  • This paper presents an improved ZVT(Zero Voltage Transition) DC/DC Boost Converter using Active Snubber. The Conventional ZVT PWM Boost Converter is improved to minimize the switching loss of auxiliary switch using the minimum number of the components. In this thesis, advantage and disadvantages of Conventional ZVT Converter using a auxiliary resonant circuit is discussed. Then Improved ZVT soft switching converter will be discussed. In comparison a previous ZVT converter, The proposed converter reduces turn-off switching loss of the auxiliary switch Therefore, the proposed converter has a high efficiency by active snubber. The prototype of 100kHz, 2kW system was implemented to show the improved performance.

  • PDF

A Novel Recovery Circuit of a Leakage Inductance Stored Energy in Flyback Converter (플라이백 컨버터에서 누설인덕턴스 저장에너지의 새로운 회복회로)

  • Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.526-528
    • /
    • 2005
  • Nowadays, more than ever before, many researchers are paying attention to raising the efficiency of a Power converter. In Flyback converter, the resistor of RCD snubber consumes the stored energy in leakage inductor. It play a role in degrading the overall system efficiency Thus, In this paper, a novel energy recovery circuit of Flyback converter is proposed to improve the efficiency. The operational principle of the proposed circuit is explained in detail. And, it is verified through the simulation results.

  • PDF

A Soft switching method for Loss reduction of Inverter (인버터의 손실저감을 위한 소프트 스위칭기법)

  • 곽동걸;김영철;이현우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

A Three Level ZVZCS Phase-Shifted DC/DC Converter Using A Tapped Inductor And A Snubber Capacitor (탭-인덕터와 스너버-커패시터를 적용한 3 Level 영전압.영전류 스위칭 DC/DC 컨버터)

  • 김은수;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.209-216
    • /
    • 2001
  • The conventional three-level high frequency phase-shifted dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current and RMS current stress, conduction losses of transformer and switching devices increases. To alleviate these problems, we propose an improved three-level Zero Voltage and Zero Current Switchig (ZVZCS) dc/dc converter using a tapped inductor, a snubber capacitor and two snubber diodes attached at the secondary side of transformer. The proposed ZVZCS converter is verified on a 7kW, 30kHz experimental prototype.

  • PDF

Three-Phase Soft Switching Sinewave Inverter with Bridge Power Module Package Configurated Auxiliary Resonant AC Link Snubber

  • Iyomori Hisashi;Nagai Shin-ichiro;Shiraishi Kazuhiro;Ahmed Tarek;Eiji Hiraki;Mutsuo Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.507-510
    • /
    • 2003
  • This paper presents a novel prototype of tile three-phase bridge power block module type a auxiliary resonant AC link snubber circuit, which is effectively used for the three-phase voltage source type sinewave soft switching PWM inverter using IGBTs. Its operating principle Is described for current source load model, along with its practical design approach based on the simulation data. The performance evaluation of the three-phase voltage source type snewave soft switching PWM inverter incorporating a single three-phase bridge mo여le of active auxiliary resonant AC link snubber treated here Is illustrated, which is concerned with power duality efficiency power loss analysis. This inverter is discussed as compared with those of tile three-phase voltage source type sinewave hard switching PWM inverter. The power loss analysis of this soft switching PWM Inverter using IGBT power modules is evaluated on the basis of the measured v-i characteristics and switching power losses of IGBT, and antiparaliel diodes. The practical effectiveness of this inverter is proven by the power loss analysis for distributed power supply.

  • PDF

Design Criteria of the Auxiliary Resonant Snubber Inverter Using a Load-Side Circuit for Electric Propulsion Drives

  • Song, Byeong-Mun;Jih-Sheng(Jason) Lai;Kwon, Soon-Kurl
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.143-148
    • /
    • 1998
  • The Design criteria of the auxiliary resonant snubber inverter (ARSI) using a load-side circuit are discussed in relation to electric propulsion drives. In this regard, this paper attempts to develop a set of design criteria for the ARSI. First, the switching characteristics of IGBTs under soft-switching mainly in terms of dv/dt/, di/dt and switching losses are discussed and utilized for optimizing the selection of the resonant components in the system. After that, the proper control strategies of ARSIs are analyzed and simulated based on voltage space vector modulations. Later, the design, control and implementation of the auxiliary resonant circuit suitable for industrial products are analyzed and presented. And finally, other factors including power stage layout, packaging and the choice of current sensors are included. The detailed simulation and experimental results will be included based on a laboratory prototype. The proposed design criteria of the ARSI would help the implementation of an electric propulsion drive system.

  • PDF