• Title/Summary/Keyword: Snow Load

Search Result 95, Processing Time 0.022 seconds

Generalized load cycles for dynamic wind uplift evaluation of rigid membrane roofing systems

  • Baskaran, A.;Murty, B.;Tanaka, H.
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.383-411
    • /
    • 2011
  • Roof is an integral part of building envelope. It protects occupants from environmental forces such as wind, rain, snow and others. Among those environmental forces, wind is a major factor that can cause structural roof damages. Roof due to wind actions can exhibit either flexible or rigid system responses. At present, a dynamic test procedure available is CSA A123.21-04 for the wind uplift resistance evaluation of flexible membrane-roofing systems and there is no dynamic test procedure available in North America for wind uplift resistance evaluation of rigid membrane-roofing system. In order to incorporate rigid membrane-roofing systems into the CSA A123.21-04 testing procedure, this paper presents the development of a load cycle. For this process, the present study compared the wind performance of rigid systems with the flexible systems. Analysis of the pressure time histories data using probability distribution function and power spectral density verified that these two roofs types exhibit different system responses under wind forces. Rain flow counting method was applied on the wind tunnel time histories data. Calculated wind load cycles were compared with the existing load cycle of CSA A123.21-04. With the input from the roof manufacturers and roofing associations, the developed load cycles had been generalized and extended to evaluate the ultimate wind uplift resistance capacity of rigid roofs. This new knowledge is integrated into the new edition of CSA A123.21-10 so that the standard can be used to evaluate wind uplift resistance capacity of membrane roofing systems.

The analysis of electrical characteristics with Micro-crack in PV module (Micro-cracks에 의한 PV 모듈의 전기적 특성 분석)

  • Song, Young-Hun;Ji, Yand-Geun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

Nonlinear Analysis of Curved Cable-Membrane Roof Systems (굴곡형 케이블-막 지붕 시스템의 비선형 해석)

  • Park, Kang-Geun;Kwun, Ik-No;Lee, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.3
    • /
    • pp.45-55
    • /
    • 2017
  • The objective of this study is to estimate the mechanical characteristics and nonlinear behaviors on the geometric nonlinear analysis of curved cable-membrane roof systems for long span lightweight roof structures. The weight of a cable-membrane roof dramatically can reduce, but the single layer cable-membrane roof systems are too flexible and difficult to achieve the required structural stiffness. A curved cable roof system with reverse curvature works more effectively as a load bearing system, the pretension of cables can easily increase the structural stiffness. The curved cable roof system can transmit vertical loads in up and downward direction, and work effectively as a load bearing structure to resists self-weights, snow and wind loads. The nonlinear behavior and mechanical characteristics of a cable roof system has greatly an affect by the sag and pretension. This paper is carried out analyzing and comparing the tensile forces and deflection of curved roof systems by vertical loads. The elements for analysis uses a tension only cable element and a triangular membrane element with 3 degree of freedom in each node. The authors will show that the curved cable-membrane roof system with reverse curvature is a very lightweight and small deformation roof for external loads.

Sensitivity of Seismic Response and Fragility to Parameter Uncertainty of Single-Layer Reticulated Domes

  • Zhong, Jie;Zhi, Xudong;Fan, Feng
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1607-1616
    • /
    • 2018
  • Quantitatively modeling and propagating all sources of uncertainty stand at the core of seismic fragility assessment of structures. This paper investigates the effects of various sources of uncertainty on seismic responses and seismic fragility estimates of single-layer reticulated domes. Sensitivity analyses are performed to examine the sensitivity of typical seismic responses to uncertainties in structural modeling parameters, and the results suggest that the variability in structural damping, yielding strength, steel ultimate strain, dead load and snow load has significant effects on the seismic responses, and these five parameters should be taken as random variables in the seismic fragility assessment. Based on this, fragility estimates and fragility curves incorporating different levels of uncertainty are obtained on the basis of the results of incremental dynamic analyses on the corresponding set of 40 sample models generated by Latin Hypercube Sampling method. The comparisons of these fragility curves illustrate that, the inclusion of only ground motion uncertainty is inappropriate and inadequate, and the appropriate way is incorporating the variability in the five identified structural modeling parameters as well into the seismic fragility assessment of single-layer reticulated domes.

Wind load analysis for designing a tracking solar generator (추적식 태양광 발전기 설계를 위한 풍하중 해석)

  • Kim, Young-Eun;Jeong, Kyu-Won;Lee, Jae-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.672-680
    • /
    • 2017
  • A solar photovoltaic system is composed of a module mounting structure, supporting trunk, and a control unit that supplies generated electrical power to an external power grid or a load. The efficiency of the system depends on the incident solar light, so the mounting structure is installed to face the sun. However, because the sun always moves, systems that track the sun have better efficiency than fixed systems. The structure experiences wind pressure, snow load, seismic load, and structure weight. The wind pressure has the most serious effect on the structure. The pressure was obtained using finite element method for various gaps between modules and angles between the panel and the ground. The wind pressure is lowest when the gap is zero, and it increases with the inclination angle. Based on the results, a mounting structure module was designed.

Rehabilitation of a distressed steel roof truss - A study

  • Dar, M.A.;Subramanian, N.;Dar, A.R.;Raju, J.
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.567-576
    • /
    • 2017
  • Structural failures are undesirable events that devastate the construction industry resulting in loss of life, injury, huge property loss, and also affect the economy of the region. Roof truss failures occur mainly due to excessive loading, improper fabrication, deterioration, inadequate repair, etc. Although very rare, a roof truss may even fail due to inappropriate location of supports. One such case was reported from the recent failure of a steel roof truss used in an indoor stadium at Kargil in India. Kargil region, being mountainous in nature, receives heavy snowfall and hence the steel roof trusses are designed for heavy snow loads. Due to inappropriate support location, the indoor stadium's steel roof truss had failed under heavy snow load for which it was designed and became an interesting structural engineering problem. The failure observed was primarily in terms of yielding of the bottom chord under the supports, leading to partial collapse of the roof truss. This paper summarizes the results of laboratory tests and analytical studies that focused on the validation of the proposed remedial measure for rehabilitating this distressed steel roof truss. The study presents the evaluation of (i) significant reduction in strength and stiffness of the distressed truss resulting in its failure, (ii) desired recovery in both strength and stiffness of the rectified truss contributed by the proposed remedial measure. Three types of models i.e., ideal truss model, as build truss model and rectified truss model were fabricated and tested under monotonic loading. The structural configuration and support condition varied in all the three models to represent the ideal truss, distressed truss and the rectified truss. To verify the accuracy of the experimental results, an analytical study was carried out and the results of this analytical study are compared with the experimental ones.

Design of Improved Switch Point Heating System for Low Power and Simplified Equipment (저전력 및 설비간략화를 위한 선로전환기용 융설장치 설계)

  • Jang, Dongwan;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • The turnout point system is installed to separate the main rail track from other tracks in rail load stations. It is also important to set up the switch point system to change the direction of the turnout point, to lead and change the direction of tracks. The switch point system can be negatively affected by heavy snow during winter seasons which can cause critical safety problems. Furthermore, the maintenance and repair of the conventional system is prohibitively expensive due to its complexity and high probability of failure. In this paper, an efficient switch point system is proposed which simplifies the equipment structure and lowers the cost for maintenance and repair, while improving safety and performance of the rail road system.

Determination of Resonable Unit Snow Weight and Greatest Gust Speed for Design Load Estimation of Agricultural Structures and their Applications (농업시설의 설계하중 산정을 위한 적정 단위적설중량과 순간최대풍속의 결정 및 적용)

  • 김문기;손정익;남상운;이동근
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1994.05a
    • /
    • pp.111-114
    • /
    • 1994
  • 상대적으로 사하중에 비해서 활하중 영향이 민감하게 작용하는 농업시설의 경우, 경제성 및 안정성에 근거한 구조설계를 위해서는 활하중의 결정요인의 정확한 분석을 통한 합리적인 설계하중의 산정이 필요하다. 단위적설 중량은 적설심에 따른 구분을 사용한다면 대부분 적설심 50cm 이하의 범위에 속하기 때문에 일률적으로 1.0kg/cm/$m^2$ 을 적용해야 하지만, 정확한 적설하중 산정을 위해서 기온에 따른 단위 적설중량의 변화를 분석할 필요가 있다. (중략)

  • PDF

An Experimental Study on Monitoring Damages of Membrane Materials Using Lead Switch Sensors and Radio Frequency (리드스위치 센서와 무선주파수를 이용한 막재료의 손상 모니터링에 관한 연구)

  • Kim, Dong-Hyun;Kim, Tae-Gon;Suk, Chang-Mok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.4
    • /
    • pp.83-90
    • /
    • 2013
  • PTEF membranes are used for roofing materials of membrane structures. PTEF is the abbreviation of Poly-tetra Fluotide-ethylene. These materials are consisted of fiberglass weave and polyetrfluoroethylene coating. Also, PTEF membranes have some problems of structural capacity by wind or snow load, etc. In this study, sensor housings using lead switches are bonding in PTFE membranes, Monitoring to changes tension and tear damages are studied using radio frequency. If tension is received on edged membranes, bonded lead switches of sensor housings will be destroyed by changes tension, and these become to send signals of damages at the connected radio frequency system with increased tension. Study of these functional membrane materials will be contributed to prevent water leakage and long-term maintenance of membrane structures.

Actual Collaspe Cause and Evaluation Load Carrying Capacity of Pipe-house with the Heavy Snow (폭설에 의한 파이프하우스의 붕괴 원인 분석 및 하중지지능력 평가)

  • Choi, Jae-Hyouk;Jeong, Si-Jeong;Lee, Se-Jun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.425-428
    • /
    • 2010
  • 시공의 용이성과 저렴한 시공비로 간단하게 설치가능한 단동형 파이프하우스는 기상이변으로 인하여 농업생산에 큰 피해를 발생시키며 동시에 농업 생산기반 자체를 위협하고 있는 실정이다. 따라서 폭설에 의한 파이프하우스의 피해를 줄이기 위해서는 실제 붕괴된 피해사례의 정확한 원인분석이 필요하다. 따라서 본 논문에서는 간략화법을 이용한 극한해석을 통해 파이프하우스의 붕괴원인 분석 방법을 개발하여 실제폭설에 의한 피해사례를 적용하여 실제 붕괴하중을 검토하였다.

  • PDF