• Title/Summary/Keyword: Smooth Curve

Search Result 237, Processing Time 0.025 seconds

Beneficial effect of Combination with Korean Red Ginseng, Gastrodia Rhizoma and Polygoni Multiflori on Cholesterol and Erectile Dysfunction in Hyperlipidemia rats (홍삼, 천마, 적하수오 병용투여에 의한 고지혈증 랫드에서의 콜레스테롤 및 발기부전 개선효과)

  • Lee, Yun Jung;Kho, Min Chul;Tan, Rui;Lee, Jae Yun;Hwang, Jin Seok;Cha, Jeong Dan;Choi, Kyung Min;Kang, Dae Gill
    • The Korea Journal of Herbology
    • /
    • v.30 no.6
    • /
    • pp.69-75
    • /
    • 2015
  • Objectives : This study was designed to investigate effects of the combination with Korean Red Ginseng (Panax ginseng C.A. Meyer), Gastrodia Rhizoma (Gastrodia elata Blume) and Polygoni Multiflori Radix (Polygonum multiflorum Thunberg) on metabolic disorders including cholesterol and erectile dysfunction in hyperlipidemia rats.Methods : Animals were divided into six groups; Control with normal diet, high fat/cholesterol-diet (HFCD), fluvastatin, Korean Red Ginseng treated (KRG), and the combination treated (Korean Red Ginseng, Gastrodia Rhizoma and Polygoni Multiflori Radix; 1:1:1 for KGP1 and 2:1:1 for KGP2). The experimental groups initially received HFCD for 10 weeks and then treated orally with fluvastatin, KRG, KGP1 and KGP2 during the final 6 weeks. Erectile function was determined by the measurements of intracavernosal pressure (ICP) and maximal arterial pressure (MAP) after electrical stimulation of the cavernosal nerve.Results : KGP2 decreased the level of total cholesterol and LDL cholesterol in the sera of HFCD rats without no changes of body weights. KRG, KGP1 and KGP2 decreased the level of C-reactive protein (CRP) levels except of fluvastatin, synthetic HMG-CoA reductase inhibitor. KRG, KGP1 and KGP2 significantly increased the ICP, ICP/MAP ratio, area under the curve (AUC) compared with those of normal rat. Morphometric analyses showed that KRG, KGP1 and KGP2 increased the volume of smooth muscle and the regular arrangement of collagen fibers in corpus cavernosum of HFCD rats. The penile expression of eNOS was increased by KRG, KGP1 and KGP2.Conclusions : Based on these results, we suggest that the combination with Korean Red Ginseng, Gastrodia Rhizoma and Polygoni Multiflori may improve hyperlipidemia through regulating the lipid profiles and erectile dysfunction in rats.

Association between the severity of hypodontia and the characteristics of craniofacial morphology in a Chinese population: A cross-sectional study

  • Xin Xiong;Jiaqi Liu;Yange Wu;Chengxinyue Ye;Qinlanhui Zhang;Yufan Zhu;Wenke Yang;Jun Wang
    • The korean journal of orthodontics
    • /
    • v.53 no.3
    • /
    • pp.150-162
    • /
    • 2023
  • Objective: To investigate craniofacial differences in individuals with hypodontia and explore the relationship between craniofacial features and the number of congenitally missing teeth. Methods: A cross-sectional study was conducted among 261 Chinese patients (males, 124; females, 137; age, 7-24 years), divided into four groups (without hypodontia: no teeth missing, mild: one or two missing teeth, moderate: three to five missing teeth, severe: six or more missing teeth) according to the number of congenitally missing teeth. Differences in cephalometric measurements among the groups were analyzed. Further, multivariate linear regression and smooth curve fitting were performed to evaluate the relationship between the number of congenitally missing teeth and the cephalometric measurements. Results: In patients with hypodontia, SNA, NA-AP, FH-NA, ANB, Wits, ANS-Me/N-Me, GoGn-SN, UL-EP, and LL-EP significantly decreased, while Pog-NB, AB-NP, N-ANS, and S-Go/N-Me significantly increased. In multivariate linear regression analysis, SNB, Pog-NB, and S-Go/N-Me were positively related to the number of congenitally missing teeth. In contrast, NA-AP, FH-NA, ANB, Wits, N-Me, ANS-Me, ANS-Me/N-Me, GoGn-SN, SGn-FH (Y-axis), UL-EP, and LL-EP were negatively related, with absolute values of regression coefficients ranging from 0.147 to 0.357. Further, NA-AP, Pog-NB, S-Go/N-Me, and GoGn-SN showed the same tendency in both sexes, whereas UL-EP and LL-EP were different. Conclusions: Compared with controls, patients with hypodontia tend toward a Class III skeletal relationship, reduced lower anterior face height, flatter mandibular plane, and more retrusive lips. The number of congenitally missing teeth had a greater effect on certain characteristics of craniofacial morphology in males than in females.

Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns Subjected to Eccentric Compressive Load (편심 압축력을 받는 고강도 콘크리트 기둥의 거동에 미치는 띠철근 및 콘크리트 강도의 영향)

  • Lee, Young Ho;Chung, Heon Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.95-104
    • /
    • 2007
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns subjected to eccentric compressive loads. The twenty-four concrete columns with $200mm{\times}200mm$ square cross-section were tested. The main variables were concrete strength, spacing and configuration of lateral ties, and eccentricity ratios. From the experiment, the followings were investigated ; 1) In all cases, it was observed that the increase of concrete compressive strength led to the decrease of ductility. Also, as the eccentricity ratios increased, the effect of ductility enhancement by lateral ties decreased. 2) As the ties spacing decreased from 100mm to 30mm, the magnitude of axial load acting on the concrete column showed an enhancement of 1.1~1.2 times and the descending curve after a peak moment presented a smooth decline. 3) The high-strength concrete columns required a design of lateral ties to increase the volumetric ratios and density of tie spacing to sustain a proper strength and ductility. Accordingly, regardless of concrete strength, the current AIK design code to specify the maximum tie spacing of concrete columns was proven to lead to the poor strength and ductility for seismic design. Therefore, it is necessary to develop a new seismic design code that connects volumetric ratios and tie spacing of concrete columns with concrete strength.

Study on Relaxing Effect of Oxybutynin on the Contractile Response of Arterial Smooth Muscle (동맥근 수축에 대학 Oxybutynin의 이완효과에 관한 연구)

  • Ko, Jae-Ki;Baik, Yung-Hong
    • The Korean Journal of Pharmacology
    • /
    • v.24 no.1
    • /
    • pp.93-101
    • /
    • 1988
  • Pharmacological actions of an antispasmodic agent, oxybutynin were investigated in the isolated procine coronary arteries. The coronary rings were contracted by acetylcholine (ACh) and KCl in a dose-dependent fashion. The ACh-induced contractions were signifcantly potentiated by removal of endothelium and $EC_{50}=0.52\;{\mu}M$ of intact endothelial rings was about 2 times greater than $EC_{50}=0.28\;{\mu}M$ of rings without the endothelium. These results suggest that the endothelium plays an inhibitory role in ACh-induced contraction. Oxybutynin and atropine inhibited dose-dependently $1.0\;{\mu}M$ ACh-induced contraction and atropine inhibited dose-dependently $1.0\;{\mu}M$ ACh-induced contraction and the $IC_{50s}$ were 11.0 nM and 0.47 nM, respectively. Atropine did not affect 35 mM KCl-induced contraction but oxybutynin inhibited the contraction to the basal tension in a dose-dependent manner. The $IC_{50}$ of oxybutynin on the KCl-induced contraction was $49.7\;{\mu}M$. The dose-response curve to ACh was parallelly shifted to the right by pretreating coronary rings with $IC_{50}$ of atropine (0.47 nM) or oxybutynin (11.0 nM) but the curve to KC1 was rightward shifted in a noncompetitive manner under pretreatment with $IC_{50}$ of oxybutynin $(49.7\;{\mu}M$). Oxybutynin inhibited $0.1\;{\mu}M$ Bay K 8644-induced contraction to the basal tension in a dose dependent manner, but $35\;{\mu}M$ histamine-induced contraction was inhibited to only 50e/e of the original level even in maximal concentration $(5{\times}10^{-4}M)$ of oxybutynin. These results suggest that oxybutynin causes antispasmodic action through sensitive blocking action on muscarinic receptors and inhibitory action on calcium influx in the procine coronary artery.

  • PDF

A STUDY ON THE MANDIBULAR MOVEMENT CHANGES AFTER ORTHOGNATHIC SURGERY IN SKELETAL CLASS III PATIENTS (악교정 수술 후 골격성 III급 부정교합 환자의 하악운동 변화에 관한 연구)

  • Nahm, Dong-Seok;Suhr, Cheong-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.273-282
    • /
    • 1997
  • The purpose of this study was to evaluate changes in mandibular movement patterns after orthognathic surgery in skeletal Class III patients. The sample consisted of 20 Class III malocclusion patients(9 males, 11 females). Just before and after(2-7months) surgery, maximum opening & closing movement, mandibular border movement on sagittal, frontal and horizontal planes were recorded using Sirognathograph & BioPak EGN. On each record, 21 items were measured and statistically analyzed. The results were as follows 1. Angle of protrusive movement on sagittal plane showed greatest change after surgery. Also, as the incisal guidance was established by surgery, straight path of protrusive movement became curved line. 2. Maximum opening distance and maximum antero-posterior distance on maximum opening & closing movement, maximum opening distance on sagittal plane, angle of left lateral excursion on frontal plane were statistically significant after snrgery(p<0.01). 3. Maximum width of lateral excursion on frontal plane, distane of right lateral excursion and angle of maximum left lateral excursion on horizontal plane were statistiraily significant after surgery(p<0.05). 4. Maximum opening distance and maximum antero-posterior distance on maximum opening & closing movement showed significant differences according to post-surgical time(p<0.05). More recovery of range of movement occured in 5-7month group than in 2-3month group. 5. As the occlusal interferences were removed by orthognathic surgery, irregular opening & closing path became smooth curve.

  • PDF

Evaluation for Rock Cleavage Using Distribution of Microcrack Lengths (미세균열의 길이 분포를 이용한 결의 평가)

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.165-180
    • /
    • 2015
  • Jurassic granite from Geochang was analysed with respect to the characteristics of the rock cleavage. The phases of distribution of microcracks were well evidenced from the enlarged photomicrographs(${\times}6.7$) of the thin section. In this study, the length - cumulative frequency diagrams were used for expressing the distribution characteristics of microcrack. The diagrams for the six directions were arranged in the magnitude of density(${\rho}$). These diagrams show an order of H2 < H1 < G2 < G1 < R2 < R1 from the related chart. Among six diagrams, the diagram for hardway 2(H2) occupies the lowermost region on the left. On the contrary, the diagram for rift 1(R1) occupies the uppermost region on the right. Curve patterns of the two diagrams change from uniform to exponential distribution type in accordance with the increased density. The overall distribution characteristics of the diagrams were well evidenced from the magnitude of the exponent(${\lambda}$) and length of line oa related to the exponential straight line. The magnitude of exponent governing the values of slope(${\theta}$) is inversely proportional to the values of microcrack parameters such as number(N), length(L) and density. On the contrary, length of line oa is directly proportional to the values of the above three parameters. Above microcrack parameters related to the order of arrangement of diagrams show an order of hardway(H1 + H2) < grain(G1 + G2) < rift(R1 + R2). The distribution characteristics of progressive variation are found among the six diagrams. The order of arrangement of the diagrams indicates a relative magnitude of the rock cleavage. Meanwhile, the parameters such as slope, exponent, density and length of line oa were arranged in an order of H2 < H1 < G2 < G1 < R2 < R1. The variation curves of a smooth quadratic function are shown from the related chart. From the correlation chart between density and the above parameters, a common regularity following power-law correlation function was derived. Finally, the analysis for the rock cleavage was conducted through the combination between the diagram and microcrack parameter. This type of combination contribute to the progressivity in evaluation for the rock cleavage.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF