• Title/Summary/Keyword: Smoke particles

Search Result 80, Processing Time 0.029 seconds

Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles - (도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 -)

  • Baek Sung-Ok;Park Sang-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

Photon Mapping-Based Rendering Technique for Smoke Particles (연기 파티클에 대한 포톤 매핑 기반의 렌더링 기법)

  • Song, Ki-Dong;Ihm, In-Sung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.4
    • /
    • pp.7-18
    • /
    • 2008
  • To realistically produce fluids such as smoke for the visual effects in the films or animations, we need two main processes: a physics-based modeling of smoke and a rendering of smoke simulation data, based on light transport theory. In the computer graphics community, the physics-based fluids simulation is generally adopted for smoke modeling. Recently, the interest of the particle-based Lagrangian simulation methods is increasing due to the advantages at simulation time, instead of the grid-based Eulerian simulation methods which was widely used. As a result, because the smoke rendering technique depends heavily on the modeling method, the research for rendering of the particle-based smoke data still remains challenging while the research for rendering of the grid-based smoke data is actively in progress. This paper focuses on realistic rendering technique for the smoke particles produced by Lagrangian simulation method. This paper introduces a technique which is called particle map, that is the expansion and modification of photon mapping technique for the particle data. And then, this paper suggests the novel particle map technique and shows the differences and improvements, compared to previous work. In addition, this paper presents irradiance map technique which is the pre-calculation of the multiple scattering term in the volume rendering equation to enhance efficiency at rendering time.

  • PDF

A Characteristics of Smoke Layer Formation Affected Periodicity of Fire Plumes (Plume의 주기성이 연층형성에 미치는 영향)

  • 한용식;김명배;오광철;신현동
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.38-42
    • /
    • 2002
  • This experiment is to understand a characteristics of smoke layer formation affected periodicity of fire plumes. The ON-OFF jet was used to constitute the oscillating flow, which was formed by a mixture of nitrogen gas with kerosene particles. The instantaneous images was obtained by digital video camera using laser sheet technique. The results were confirmed that the smoke layer in the near fire source comprise vortices which are formed by impingement from the periodicity of fire plume. The periodic impinging of plumes were thickened the smoke layer and produced the back-flow.

Respiratory Protection for LASER Users

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The plume produced by vaporizing tissue with a laser contains a variety of contaminants called laser-generated air pollutants (LGACs). LGACs consist of a mixture of toxic gas components, biomicroparticles, dead and living cells, and viruses. Toxic odors and thick smoke from surgical incisions and the coagulation of tissues can irritate eyes and airways, as well as cause bronchial and pulmonary congestion. Because of the potential risk of the smoke, it is advisable to appropriately remove it from the surgical site. We recommend using a smoke evacuator to remove the smoke. Suction nozzles should be placed as close as possible to the surgical site in a range of 2 cm or less. In-line filters should be used between the inlet and outlet of the surgical site. All air filtration devices should be capable of removing particles below 0.1 microns in size. The filter pack should be handled according to infection control procedures in the operating room. The laser mask can be an auxiliary protective device if it is properly worn. Some smoke inhaled under the nose wrap or over the side of the mask will not be filtered. As in electrosurgical operations, a suitable mask should be worn while smoke is present.

A Numerical Study on Smoke Control for Smoke Control Systems and Air Flowrate (제연방식과 풍량에 따른 제연성능의 수치적 연구)

  • 박외철
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.56-61
    • /
    • 2003
  • The smoke removal rate from a room with an opening was investigated for different smoke control systems by using the large eddy simulation turbulence model of the Fire Dynamics Simulator. The decreasing rate of the particles randomly distributed in the 2m X 2m X 2.4m room was com-pared for the ventilation system, pressurization system and extraction system, and for the air flowrate of the ventilation system. Difference in the smoke removal rate among the three smoke control systems was small when the opening was closed. The pressurization system showed less smoke removal rate than the other two systems when the opening existed, and hence is not recommended for subway stations with large openings. It was also shown that a less flowrate in the ventilation system leads to a much longer smoke removal time.

Preparation of Ultrafine Au-Pb Particles by Gas-evaporation Technique

  • Ohno, Takehisa;Funaguchi, Hironori
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.158-159
    • /
    • 2006
  • Ultrafine Au-Pb particles prepared by two method, (1) simultaneous evaporation of Au and Pb in inert gas and (2) subsequent vapor condensation of Pb in a differentially evacuated tube onto flying Au nanoparticles prepared by gasevaporation technique, were observed by electron microscopy. In the method (1), the particles that grew at the region where the two smoke masses converged, consisted of alloy phases. In the method (2), the particles consisted of two or three phases of Au, $Au_2Pb$, $AuPb_2$ and Pb phases in turn from the inner part, Pb-rich particles being composed of only two phases of $AuPb_2$ and Pb.

  • PDF

A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System (실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구)

  • Koo, Jeong-Hwan;Kim, Seong-Chan;Kim, Jang-Woo;Lee, Ju-Yong;Lee, Jae-Keun;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Revision of the Input Parameters for the Prediction Models of Smoke Detectors Based on the FDS (FDS 기반의 연기감지기 예측모델을 위한 입력인자 재검토)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.44-51
    • /
    • 2017
  • Accurate predictions of the activation time for smoke detectors using a fire simulation is are required to ensure the reliability of the RSET (Required Safe Egress Time) calculation in the process of PBD (Performance-Based Design). The objective of this study was to enhance the accuracy of input parameters for the numerical models of smoke detector based on the FDS. To this end, a Fire Detector Evaluator (FDE) developed in previous studies was improved. The uniformities of flow and smoke inside the FDE were improved and accurate measurements of the obscuration per meter (OPM) related to detector operation were also performed through a decrease in the forward scattering of smoke particles. The input parameters using the improved FDE showed a significant difference from the previous FDE quantitatively. In particular, a larger difference was found in a photoelectric detector compared to an ionization detector. Considering that the operating conditions of smoke detectors are affected by the detector type, combustibles, smoke particulars, and color, the database (DB) on the input parameters for various detectors and combustibles should be built to improve the reliability of PBD in future studies.

Large Eddy Simulation of Fire and Smoke Control in a Compartment with Large Openings (큰 개구부가 있는 공간의 화재와 제연의 대와류모사)

  • 박외철
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.7-12
    • /
    • 2003
  • A 50 kW polyurethane fire in a compartment of 4 m ${\times}$ 1 m ${\times}$ 1.5m with large openings similar to a subway station was simulated by a large eddy simulation to investigate the fire and smoke control. The NIST FDS, which employed a mixture fraction combustion model and a finite volume method for radiation, was utilized. Distribution of temperature and smoke particles was compared with in the lower and upper corridors for three different smoke control systems, ventilation, purge, and extraction, starting in 5 sec from the ignition of the fire. For the given geometries, the ventilation system showed the best smoke removal rate and lowest temperature distribution in the both corridors. It was confirmed that the purge system is not recommended for a subway station since the smoke removal rate of the purge system was worse than that without a smoke control system.